Artavazd Badalyan

Dr. Artavazd Badalyan


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2016 in Nature
Verified
Journal Article
Closed access
PDF file
ABArtavazd Badalyan
Artavazd Badalyan
SSShannon S. Stahl
Shannon S. Stahl

4 January 2019 in ACS Catalysis
Verified
Journal Article
Closed access
ABArtavazd Badalyan
Artavazd Badalyan
ZYZhi-Yong Yang
Zhi-Yong Yang
LSLance C. Seefeldt
Lance C. Seefeldt

4 November 2019 in Biochemistry
Verified
Journal Article
Closed access
ABArtavazd Badalyan
Artavazd Badalyan
ZYZhi-Yong Yang
Zhi-Yong Yang
BHBo Hu
Bo Hu
JLJian Luo
Jian Luo
MHMaowei Hu
Maowei Hu
LSLance C. Seefeldt
Lance C. Seefeldt

14 September 2022 in Biochemistry
Verified
Journal Article
Closed access
DHDerek F. Harris
Derek F. Harris
ABArtavazd Badalyan
Artavazd Badalyan
LSLance C. Seefeldt
Lance C. Seefeldt

2 June 2014 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
PDPradip Dey
Pradip Dey
MAMiriam Adamovski
Miriam Adamovski
SFSimon Friebe
Simon Friebe
ABArtavazd Badalyan
Artavazd Badalyan
RMRadu-Cristian Mutihac
Radu-Cristian Mutihac
RHRainer Haag
Rainer Haag

3 November 2014 in Biosensors
Verified
Journal Article
Open access
PDF file
ABArtavazd Badalyan
Artavazd Badalyan
MDMarlen Dierich
Marlen Dierich
KSKonstanze Stiba
Konstanze Stiba
VSViola Schwuchow
Viola Schwuchow
SLSilke Leimkühler
Silke Leimkühler
Ulla WollenbergerUlla Wollenberger
Ulla Wollenberger
Biosensors for the detection of benzaldehyde and g-aminobutyric acid (GABA) are reported using aldehyde oxidoreductase PaoABC from Escherichia coli immobilized in a polymer containing bound low potential osmium redox complexes. The electrically connected enzyme already electrooxidizes benzaldehyde at potentials below −0.15 V (vs. Ag|AgCl, 1 M KCl). The pH-dependence of benzaldehyde oxidation can be strongly influenced by the ionic strength. The effect is similar with the soluble osmium redox complex and therefore indicates a clear electrostatic effect on the bioelectrocatalytic efficiency of PaoABC in the osmium containing redox polymer. At lower ionic strength, the pH-optimum is high and can be switched to low pH-values at high ionic strength. This offers biosensing at high and low pH-values. A “reagentless” biosensor has been formed with enzyme wired onto a screen-printed electrode in a flow cell device. The response time to addition of benzaldehyde is 30 s, and the measuring range is between 10–150 µM and the detection limit of 5 µM (signal to noise ratio 3:1) of benzaldehyde. The relative standard deviation in a series (n = 13) for 200 µM benzaldehyde is 1.9%. For the biosensor, a response to succinic semialdehyde was also identified. Based on this response and the ability to work at high pH a biosensor for GABA is proposed by coimmobilizing GABA-aminotransferase (GABA-T) and PaoABC in the osmium containing redox polymer.