yuanyuan chen

Ms. yuanyuan chen


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
PZPeng Zhao
Peng Zhao
YLYiyi Liu
Yiyi Liu
YCyuanyuan chen
yuanyuan chen
MYMei Yang
Mei Yang
SZShixian Zhao
Shixian Zhao
Changjun HouChangjun Hou
Changjun Hou

19 December 2019 in Energies
Verified
Journal Article
Open access
PDF file
YCyuanyuan chen
yuanyuan chen
ZYZilong Yang
Zilong Yang
YWYibo Wang
Yibo Wang
The environment for practical applications of an energy storage system (ESS) in a microgrid system is very harsh, and therefore actual operating conditions become complex and changeable. In addition, the signal of the ESS sampling process contains a great deal of system and measurement noise, the sampled current fluctuates significantly, and also has high frequency. In this case, under such conditions, it is difficult to accurately estimate the state of charge (SOC) of the batteries in the ESS by common estimation methods. Therefore, this study proposes a compound SOC estimation method based on wavelet transform. This algorithm is very suitable for microgrid systems with large current, frequent fluctuating conditions, and high noise interference. The experimental results and engineering data show that the relative error of the method is 0.5%, which is much lower than the extend Kalman filter (EKF) based on wavelet transform.

31 January 2018 in Journal of Wuhan University of Technology-Mater. Sci. Ed.
Verified
Journal Article
Closed access
PDF file
HXHan Xiao
Han Xiao
LLLiwen Lei
Liwen Lei
ZWZhiqiang Wang
Zhiqiang Wang
YCyuanyuan chen
yuanyuan chen

1 January 2022 in Thermal Science
Verified
Journal Article
Open access
PDF file
YCyuanyuan chen
yuanyuan chen
Yi-Wei ChenYi-Wei Chen
Yi-Wei Chen
XXXuecheng Xu
Xuecheng Xu
Porous foam is an ideal material for enhancing radiative heat transfer in numerous thermal equipment. The solid skeletons of porous foams can absorb/ release radiative energy and transfer convective energy with the surrounding fluid in the pores. In this paper, the conduction-convection-radiation coupling heat transfer in a porous cavity is investigated. A local thermal nonequilibrium model is used to represent the energy transport during the solid and fluid phases. The heat flux caused by thermal radiation is obtained by solving the radiation transfer equation. The thermal and fluid fields are studied to discern various parameters, including the Planck numbers Pl , the modified Rayleigh numbers Ra , and the interphase heat transfer coefficients H . Our study indicates the following: (1) the effect of radiation can be neglected when Pl > 20; (2) the modified Rayleigh numbers have little influence on the solid temperature when the radiative heat transfer is dominant and the convective heat transfer between the two phases is weak; and (3) the local thermal-equilibrium can be formed when H exhibits high values.

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
XGXueyou Gao
Xueyou Gao
HXHang Xue
Hang Xue
YZYue Zhou
Yue Zhou
YCyuanyuan chen
yuanyuan chen
Jian PengJian Peng
Jian Peng
Peroxidase-like activity of artificial enzymes has been widely used for biosensing. However, the peroxidase-like activity of artificial enzymes is far from satisfactory in contrast to natural enzymes. Herein, by imitating the structure of natural enzymes, we propose a one-pot annealing process to prepare imidazole ring-doped graphitic carbon nitride with enhanced peroxidase-like activity. By adding histidine during calcination, the graphite-phase carbon nitride doped with imidazole rings (g-C3N4-His) is obtained, which shows enhanced peroxidase-like activity by 46.5 times compared to bare g-C3N4. Furthermore, imidazole rings from g-C3N4-His make it possible to anchor Cu(II) active sites on it to produce g-C3N4-His-Cu, which show another 3 times increased peroxidase-like activity. It should be noted that the as-prepared g-C3N4-His-Cu could work in wide pH (4-9) and low temperature (5 oC). The ultrahigh peroxidase-like activity is attributed to the electronic effect of imidazole rings and active sites of Cu(II) for ·OH production. Based on the enhanced peroxidase-like activity, a H2O2 and glucose biosensor is developed with high sensitivity (limit of detection 10 nM) and selectivity. Therefore, the biosensor shows potential applications in diabetic diagnosis in clinic.

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
XGXueyou Gao
Xueyou Gao
HXHang Xue
Hang Xue
YZYue Zhou
Yue Zhou
YCyuanyuan chen
yuanyuan chen
Jian PengJian Peng
Jian Peng
Peroxidase-like activity of artificial enzymes has been widely used for biosensing. However, the peroxidase-like activity of artificial enzymes is far from satisfactory in contrast to natural enzymes. Herein, by imitating the structure of natural enzymes, we propose a one-pot annealing process to prepare imidazole ring-doped graphitic carbon nitride with enhanced peroxidase-like activity. By adding histidine during calcination, the graphite-phase carbon nitride doped with imidazole rings (g-C3N4-His) is obtained, which shows enhanced peroxidase-like activity by 46.5 times compared to bare g-C3N4. Furthermore, imidazole rings from g-C3N4-His make it possible to anchor Cu (II) active sites on it to produce g-C3N4-His-Cu, which show another 3 times increased peroxidase-like activity. It should be noted that the as-prepared g-C3N4-His-Cu could work in wide pH (4-9) and low temperature (5 oC) conditions. The ultrahigh peroxidase-like activity is attributed to the electronic effect of imidazole rings and active sites of Cu (II) for ·OH production. Based on the enhanced peroxidase-like activity, a H2O2 and glucose biosensor is developed with high sensitivity (limit of detection 10 nM). The results show that the g-C3N4-His-Cu has high selectivity and sensitivity for glucose detection in urea of diabetic patients. Therefore, the biosensor shows potential applications in diabetic diagnosis in clinic.