Snow is one of the most critical sources of freshwater, which influences the global water cycle and climate change. However, it is difficult to monitor global snow variations with high spatial–temporal resolution using traditional techniques due to their costly and labor-intensive nature. Nowadays, the Global Positioning System Interferometric Reflectometry (GPS-IR) technique can measure the average snow depth around a GPS antenna using its signal-to-noise ratio (SNR) data. Previous studies focused on the use of GPS data at sites located in flat areas or on very gentle slopes. In this contribution, we propose a strategy called the Tilted Surface Strategy (TSS), which uses the SNR data reflected only from the flat quadrants to estimate the snow depth instead of the conventional strategy, which employs all the SNR data reflected from the whole area around a GPS antenna. Three geodetic GPS sites from the Plate Boundary Observatory (PBO) project were chosen in this experimental study, of which GPS sites p683 and p101 were located on slopes with their gradients up to 18% and the site p025 was located on a flat area. Comparing the snow depths derived with the GPS-IR TSS method with the snow depth results provided with the GPS-PBO, i.e., GPS-IR with the conventional strategy, the Snowpack Telemetry (SNOTEL) network measurements and gridded Snow Data Assimilation System (SNODAS) estimates, it was found that the snow depths derived with the four methods had a good agreement, but the snow depth time series with the GPS-IR TSS method were closer to the SNOTEL measurements and the SNODAS estimates than those with GPS-PBO method. Similar observations were also obtained from the cumulative snowfall time series. Results generally indicated that for those GPS sites located on slopes, the TSS strategy works better.
Soil moisture monitoring using Global Navigation Satellite System (GNSS) multipath signals has gained continuous interests in recent years. However, traditional GNSS-interferometric reflectometry (GNSS-IR) soil moisture retrieval methods generally utilize a single frequency or single satellite, which fail to take full advantage of different and complementary of satellite signals with different frequencies. An improved algorithm for soil moisture retrieval based on principal component analysis (PCA) and entropy method using multi-frequency amplitude and phase offset fusion data was proposed in this research. The performance of the proposed soil moisture retrieval method was evaluated using data recorded by Plate Boundary Observatory (PBO) H2O networks and a self-built site in Henan, China. The results from GPS and BeiDou both showed that the retrieved soil moisture has a stronger correlation with in situ soil moisture, which can better reflect the fluctuation of ground truth measurements. Compared with the traditional method, the retrieval accuracy of the proposed method in terms of root-mean-square error (RMSE) was improved by 50.93%, and the average correlation coefficient were increased by 11.71%. This research proved that the proposed method could effectively improve retrieval accuracy due to the increasing number of frequencies and tracks clustering. Moreover, this study has illustrated the feasibility of BeiDou signals to precisely estimate surface soil moisture.
In this work, quad-frequency precise point positioning (PPP) time and frequency transfer methods using Galileo E1/E5a/E5b/E5 and BDS-3 B1I/B3I/B1C/B2a observations were proposed with corresponding mathematical models. In addition, the traditional dual-frequency (BDS-3 B1I/B3I and Galileo E1/E5a) ionospheric-free (IF) model was also described and tested for comparison. To assess the proposed method for time transfer, datasets selected from timing labs were utilized and tested. Moreover, the number of Galileo or BDS-3 satellites, pseudorange residuals, positioning accuracy and tropospheric delay at receiver end were all analyzed. The results showed that the proposed quad-frequency BDS-3 or Galileo PPP models could be used to time transfer, due to stability and accuracy identical to that of dual-frequency IF model. Furthermore, the quad-frequency models can provide potential for enhancing the reliability and redundancy compared to the dual-frequency time transfer method.