This review presents up-to-date imaging applications in the substantia nigra and its related structures used in Parkinson disease and other parkinsonian syndromes, assesses their usefulness, and di... Parkinson disease is characterized by dopaminergic cell loss in the substantia nigra of the midbrain. There are various imaging markers for Parkinson disease. Recent advances in MRI have enabled el...
Accurate detection of brain metastasis (BM) is important for cancer patients. We aimed to systematically review the performance and quality of machine-learning-based BM detection on MRI in the relevant literature. A systematic literature search was performed for relevant studies reported before April 27, 2020. We assessed the quality of the studies using modified tailored questionnaires of the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) criteria and the Checklist for Artificial Intelligence in Medical Imaging (CLAIM). Pooled detectability was calculated using an inverse-variance weighting model. A total of 12 studies were included, which showed a clear transition from classical machine learning (cML) to deep learning (DL) after 2018. The studies on DL used a larger sample size than those on cML. The cML and DL groups also differed in the composition of the dataset, and technical details such as data augmentation. The pooled proportions of detectability of BM were 88.7% (95% CI, 84–93%) and 90.1% (95% CI, 84–95%) in the cML and DL groups, respectively. The false-positive rate per person was lower in the DL group than the cML group (10 vs 135, P < 0.001). In the patient selection domain of QUADAS-2, three studies (25%) were designated as high risk due to non-consecutive enrollment and arbitrary exclusion of nodules. A comparable detectability of BM with a low false-positive rate per person was found in the DL group compared with the cML group. Improvements are required in terms of quality and study design.
29 February 2008 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: There are a few reports regarding the outcome evaluation of balloon-expandable intracranial stent placement (BEICS). The purpose of our study was to evaluate the outcome and factors related to the adverse events (AEs) of BEICS. MATERIALS AND METHODS: We evaluated 100 consecutive patients who underwent BEICS. We assessed the procedural success (residual stenosis 50%) at 6 months. We also analyzed 18 factors including symptom patterns related to AE rate. Symptom patterns revealed 1) stable patients (n = 73) with improving, stationary, or resolved symptoms; and 2) unstable patients (n = 27) with gradual worsening or fluctuating symptoms (National Institutes of Health Stroke Scale [NIHSS] ≥4) within 2 days before stent placement. RESULTS: The procedural success rate was 99%. Overall, there were 10 (10%) AEs within the 6 months: 4 (4%) minor strokes, 3 (3%) major strokes, and 3 (3%) deaths including a death from myocardial infarction. AE rate was 4.1% in stable and 25.9% in unstable patients. Restenosis at 6 months revealed 0% (0/59). Good outcome (modified Rankin Scale ≤2) at 6 months was 97% (71/73) in stable and 67% (18/27) in unstable patients. Stepwise logistic regression model revealed that symptom pattern (unstable versus stable) was the only significant risk factor (OR, 8.167; 95% CI, 1.933–34.500; P = .004). CONCLUSION: BEICS revealed a low AE and good outcome rate at 6 months, especially in the stable patients. Midterm outcome was also favorable in the unstable patient group.