Lijun BAO

Dr. Lijun BAO


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2016 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
LBLijun BAO
Lijun BAO
XLXu Li
Xu Li
CCCongbo Cai
Congbo Cai
ZCZhong Chen
Zhong Chen
PZPeter C. M. van Zijl
Peter C. M. van Zijl
The reconstruction of MR quantitative susceptibility mapping (QSM) from local phase measurements is an ill posed inverse problem and different regularization strategies incorporating a priori information extracted from magnitude and phase images have been proposed. However, the anatomy observed in magnitude and phase images does not always coincide spatially with that in susceptibility maps, which could give erroneous estimation in the reconstructed susceptibility map. In this paper, we develop a structural feature based collaborative reconstruction (SFCR) method for QSM including both magnitude and susceptibility based information. The SFCR algorithm is composed of two consecutive steps corresponding to complementary reconstruction models, each with a structural feature based l 1 norm constraint and a voxel fidelity based l 2 norm constraint, which allows both the structure edges and tiny features to be recovered, whereas the noise and artifacts could be reduced. In the M-step, the initial susceptibility map is reconstructed by employing a k-space based compressed sensing model incorporating magnitude prior. In the S-step, the susceptibility map is fitted in spatial domain using weighted constraints derived from the initial susceptibility map from the M-step. Simulations and in vivo human experiments at 7T MRI show that the SFCR method provides high quality susceptibility maps with improved RMSE and MSSIM. Finally, the susceptibility values of deep gray matter are analyzed in multiple head positions, with the supine position most approximate to the gold standard COSMOS result.

1 August 2019 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
LBLijun BAO
Lijun BAO
FYFuze Ye
Fuze Ye
CCCongbo Cai
Congbo Cai
JWJian Wu
Jian Wu
KZKun Zeng
Kun Zeng
ZCZhong Chen
Zhong Chen

1 May 2013 in Medical Image Analysis
Verified
Journal Article
Closed access
LBLijun BAO
Lijun BAO
MRMarc Robini
Marc Robini
WLWanyu Liu
Wanyu Liu
YZYuemin Zhu
Yuemin Zhu

9 October 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
JFJinsheng Fang
Jinsheng Fang
LBLijun BAO
Lijun BAO
XLXu Li
Xu Li
PZPeter C.M. van Zijl
Peter C.M. van Zijl
ZCZhong Chen
Zhong Chen

5 February 2024 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
ZWZi Wang
Zi Wang
HFHaoming Fang
Haoming Fang
CQChen Qian
Chen Qian
BSBoxuan Shi
Boxuan Shi
LBLijun BAO
Lijun BAO
XQXiaobo Qu
Xiaobo Qu
Magnetic resonance imaging (MRI) is an essential diagnostic tool that suffers from prolonged scan time. To alleviate this limitation, advanced fast MRI technology attracts extensive research interests. Recent deep learning has shown its great potential in improving image quality and reconstruction speed. Faithful coil sensitivity estimation is vital for MRI reconstruction. However, most deep learning methods still rely on pre-estimated sensitivity maps and ignore their inaccuracy, resulting in the significant quality degradation of reconstructed images. In this work, we propose a Joint Deep Sensitivity estimation and Image reconstruction network, called JDSI. During the image artifacts removal, it gradually provides more faithful sensitivity maps with high-frequency information, leading to improved image reconstructions. To understand the behavior of the network, the mutual promotion of sensitivity estimation and image reconstruction is revealed through the visualization of network intermediate results. Results on in vivo datasets and radiologist reader study demonstrate that, for both calibration-based and calibrationless reconstruction, the proposed JDSI achieves the state-of-the-art performance visually and quantitatively, especially when the acceleration factor is high. Additionally, JDSI owns nice robustness to patients and autocalibration signals.

20 October 2020 in Medical Image Analysis
Verified
Journal Article
Closed access
LBLijun BAO
Lijun BAO
CXCongcong Xiong
Congcong Xiong
WWWenping Wei
Wenping Wei
ZCZhong Chen
Zhong Chen
PZPeter C.M. van Zijl
Peter C.M. van Zijl
XLXu Li
Xu Li