Paolo Pollice

Dr. Paolo Pollice

Institute of Cardiovascular Disease, University of Bari Aldo Moro, Bari, Puglia, Italy
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2020 in Endocrine, Metabolic & Immune Disorders - Drug Targets
Verified
Journal Article
Closed access
PDF file
CCCarlo Caiati
Carlo Caiati
Paolo PollicePaolo Pollice
Paolo Pollice
SFStefano Favale
Stefano Favale
MLMario Erminio Lepera
Mario Erminio Lepera
Background:: Glyphosate (G) is the most common weed-killer in the world. Every year tons and tons of G are applied on crop fields. G was first introduced in the mid 1970s and since then its usage has gradually increased to reach a peak since 2005. Now G usage is approximately 100 -fold what it was in 1970. Its impact on human health was considered benign at the beginning. But over the years, evidence of a pervasive negative effect of this pesticide on humans has been mounting. Nonetheless, G usage is allowed by government health control agencies (both in the United States and Europe), that rely upon the evidence produced by the G producer. However, the IARC (International Agency for Research on Cancer) in 2015 has stated that G is probable carcinogenic (class 2A), the second highest class in terms of risk. Objective:: In this review, we explore the effect of G on human health, focusing in particular on more recent knowledge. Results:: We have attempted to untangle the controversy about the dangers of the product for human beings in view of a very recent development, when the so -called Monsanto Papers, consisting of Emails and memos from Monsanto came to light, revealing a coordinated strategy to manipulate the debate about the safety of glyphosate to the company’s advantage. Conclusions:: The story of G is a recurrent one (see the tobacco story), that seriously jeopardizes the credibility of the scientific study in the modern era.

19 November 2019 in Antibiotics
Verified
Journal Article
Open access
PDF file
CCCarlo Caiati
Carlo Caiati
Paolo PollicePaolo Pollice
Paolo Pollice
MLMario Erminio Lepera
Mario Erminio Lepera
SFStefano Favale
Stefano Favale
Lead pacemaker infection is a complication on the rise. An infected oscillating mass attached to the leads (ILV) is a common finding in this setting. Percutaneous extraction of the leads and of the device is the best curative option. However, extraction of leads with large masses can be complicated by pulmonary embolism. The aim of this study was to understand the factors associated with large ILV using a sophisticated ultrasound technique to visualize the masses, namely intracardiac echocardiography (ICE), and investigate whether larger masses induce more complications during and after extraction. Percutaneous lead extraction and peri-procedural ICE were done in 36 patients (pts) (75 ± 11 years old, 74% males). Vegetations (max dimension = 8.2 ± 4.1 mm) in the right cavity were found in 26 of them, mostly adhering to the leads. We subdivided the patients into 2 groups: with vegetation size < 1 cm (18 pts) and vegetation size ≥ 1 cm (8 pts). By univariate analysis, we found that patients in group 1 were more often taking anticoagulation therapy (p = 0.03, Phi (Phi coefficient) = −0.5, OR [odds ratio] 0.071) and had signs of local pocket infection (p = 0.02, Phi = −0.52, OR 0.059) while significantly more patients in group 2 had diabetes (p = 0.08, Phi = 0.566, OR 15); moreover the patients in group 2 showed a trend toward a more frequent positive blood culture (p = 0.08, Phi = 0.39, OR 5.8) and infection with coagulase negative staphylococci (p = 0.06, Phi = 0.46, OR 8.3). At multivariate analysis, only 3 factors (diabetes, younger age and anticoagulation therapy) were independently associated with ILV size: diabetes, associated with larger vegetations (group 2), showed the largest beta value (0.44, p = 0.008); age was inversely correlated with ILV size (beta value = −32, p = 0.038), and anticoagulation therapy (beta value = −029, p = 0.048) was more commonly associated with smaller vegetations (group 1). Larger ILV were not associated with more complications or death during or after the extraction. Conclusion: diabetes, anticoagulation therapy and age are independent predictors of lead vegetation size. The embolic potential of large ILV during extraction was modest, so ILVs >1cm are not a contraindication to percutaneous extraction of infected leads.

8 August 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
CCCarlo Caiati
Carlo Caiati
GLGiovanni Luzzi
Giovanni Luzzi
Paolo PollicePaolo Pollice
Paolo Pollice
SFStefano Favale
Stefano Favale
MLMario Erminio Lepera
Mario Erminio Lepera
Background: A lead-reactive fibrous capsule (FC) identified by ultrasounds as an atrial or ventricular lead thickness of more than 1 mm above the vendor-declared lead diameter (TL) and its local fibrotic attachment to the cardiac wall (FAC) have never been investigated in vivo, so their relationship with post-extraction masses (ghost) is not known. Methods: Intracardiac echocardiography (ICE) was performed twice during the same extraction procedure in 40 consecutive patients: before and immediately after infected lead extraction Results: The ghost detection rate was high: 60% (24/40 patients); ICE could identify both TL and FAC, TL being noted in 25/40 (62%) patients and FAC in 12/40 patients (30%). Both TL and FAC were significantly associated with ghosts (p < 0.001 and p = 0.002, respectively), but TL had a higher prediction power. The specificity was similar: 94% (15/16) and 100% (16/16), respectively, but TL showed a much higher sensitivity: 100%, (24/24) vs 50% (12/24) (p = 0.016). The ghost group did not show a higher event rate in the follow-up (mean follow-up time = 20 ± 17 months). Conclusion: ICE is able to evaluate both TL and FAC in vivo; ghosts are mostly benign remnants of fibrotic lead capsule cut off during extraction and retained inside the heart by FAC.

7 April 2020 in Coronary Artery Disease
Verified
Journal Article
Closed access
CCCarlo Caiati
Carlo Caiati
MLMario Erminio Lepera
Mario Erminio Lepera
Paolo PollicePaolo Pollice
Paolo Pollice
FIFortunato Iacovelli
Fortunato Iacovelli
SFStefano Favale
Stefano Favale
Background A more sensitive transthoracic color Doppler technology (convergent color Doppler), along with a heart rate (HR) reduction and new tomographic planes, can greatly improve coronary blood flow velocity (BFV) recordings in the left main (LMCA) and left anterior descending (LAD) coronary arteries, allowing the detection of even a slight acceleration of BFV due to mild coronary stenosis. Methods A group of 26 patients underwent convergent color Doppler transthoracic echocardiography (CC-Doppler TTE) in the LMCA and in the LAD coronary arteries before and after HR lowering. A second group of 71 patients scheduled for intravascular ultrasound, expanded to 96 with 25 more patients with normal LAD (by angiography/low likelihood of disease), underwent BFV Doppler recordings by CC-Doppler TTE of the whole LAD (specifically the proximal, mid and distal segments) to detect a localized increase in BFV, after attaining maximal and reference BFV in each segment. Results In the first group, HR reduction dramatically improved the detection of optimal flow in the LMCA and LAD, from 4 to 54% and from 6 to 94% of the segments, respectively (P < 0.001). In the second group intravascular ultrasonography (IVUS) showed mild stenoses in 60 patients. The maximum velocity was higher in the diseased segment than normal segments (49 ± 24 vs. 33 ± 11 cm/s; P < 0.001) and as the reference velocity was similar (32 ± 9 vs. 33 ± 11 cm/s; P = ns), the % increase was also higher (52 ± 52 vs. 0.7 ± 3%; P < 0.001). Using a >21% increase in velocity as a cutoff value, the sensitivity and specificity of CC-Doppler TTE in detecting at least one LAD plaque were 87% (52/60 patients [pts]) and 100% (36/36 pts), respectively. Conclusion CC-Doppler TTE evaluation of LAD BFV is greatly improved after reducing HR, allowing accurate noninvasive assessment of mild LAD stenosis with no radiation exposure.

5 February 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
CCCarlo Caiati
Carlo Caiati
ASArnaldo Scardapane
Arnaldo Scardapane
FIFortunato Iacovelli
Fortunato Iacovelli
Paolo PollicePaolo Pollice
Paolo Pollice
TATeresa Immacolata Achille
Teresa Immacolata Achille
MLMario Erminio Lepera
Mario Erminio Lepera
We report the case of a 71-year-old patient with many risk factors for coronary atherosclerosis, who underwent computed coronary angiography (CTA), in accordance with the guidelines, for recent onset atypical chest pain. CTA revealed critical (>50% lumen diameter narrowing) stenosis of the proximal anterior descending coronary, and the patient was scheduled for invasive coronary angiography (ICA). Before ICA he underwent enhanced transthoracic echo-Doppler (E-Doppler TTE) for coronary flow detection by color-guided pulsed-wave Doppler recording of the left main (LMCA) and whole left anterior descending coronary artery (LAD,) along with coronary flow reserve (CFR) in the distal LAD calculated as the ratio, of peak flow velocity during i.v. adenosine (140 mcg/Kg/m) to resting flow velocity. E-Doppler TTE mapping revealed only mild stenosis (28% area narrowing) of the mid LAD and a CFR of 3.20, in perfect agreement with the color mapping showing no flow limiting stenosis in the LMCA and LAD. ICA revealed only a very mild stenosis in the mid LAD and mild atherosclerosis in the other coronaries (intimal irregularities). Thus, coronary stenosis was better predicted by E-Doppler TTE than by CTA. Coronary flow and reserve as assessed by E-Doppler TTE trumps coronary anatomy as assessed by CTA, without exposing the patient to harmful radiation and iodinated contrast medium.

10 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
CCCarlo Caiati
Carlo Caiati
Paolo PollicePaolo Pollice
Paolo Pollice
MLMario Erminio Lepera
Mario Erminio Lepera
Background: Coronary blood flow Doppler recording by Transthoracic Doppler in convergent mode (E-Doppler TTE) might be further improved by lowering heart rate (HRL) down to <60 bpm, since low HR < 60 b/m causes a disproportional lengthening of the diastole, so the coronaries are still for a longer time, very much improving the Doppler signal/noise ratio. Methods: A group of 26 patients underwent E-Doppler TTE before and after HR lowering in four branches of the coronary tree, namely, the left main (LMCA); left anterior descending (LAD), subdivided into three segments: proximal, mid and distal; proximal left circumflex (LCx); and obtuse marginal (OM). Color and PW coronary Doppler signal was judged by two expert observers as undetectable (SCORE 1), weak or with clutter artifacts (SCORE 2), or well delineated (SCORE 3). In addition, local accelerated stenotic flow (AsF) was measured in the LAD before and after HRL. Results: Beta-blockers significantly decreased the mean HR from 76 ± 5 to 57 ± 6 bpm (p < 0.001). Before HRL, the Doppler quality was very poor in the proximal and mid-LAD segments (median score value = 1 in both), while in the distal LAD, it was significantly better but still suboptimal (median score value = 1.5, p = 0.009 vs. proximal and mid-LAD score). After HRL, blood flow Doppler recording in the three LAD segments was strikingly improved (median score value = 3, 3 and 3, p = ns), so the effect of HRL was more efficacious in the two more proximal LAD segments. In 10 patients undergoing coronary angiography (CA), no AsF as expression of transtenotic velocity was detected at baseline. After HRL, thanks to the better quality and length of color flow, ASF was detected in five patients while in five others, it was not in perfect agreement with CA (Spearman correlation coefficient = 1, p < 0.01). The color flow in the proximal LCx and OM was extremely poor at baseline (color flow length 0 and 0, median (interquartile range) mm, respectively) and improved considerably after HRL (color flow length 23 [13.5] and 25 [12.0] mm, respectively, p < 0.001). Conclusions: HRL greatly improved the success rate of blood flow Doppler recording in coronaries, not only in the LAD, but also in the LCx. Therefore, AsF for stenosis detection and coronary flow reserve assessment can have wider clinical applications. However, further studies with larger samples are needed to confirm these results.