The classification of disturbance signals is of great significance for improving power quality. The existing methods for power quality disturbance classification require a large number of samples to train the model. For small sample learning, their accuracy is relatively limited. In this paper, a hybrid algorithm of k-nearest neighbor and fully-convolutional Siamese network is proposed to classify power quality disturbances by learning small samples. Multiple convolutional layers and full connection layers are used to construct the Siamese network, and the output result of the Siamese network is used to judges the category of the signal. The simulation results show that: For small sample sizes, the accuracy of the proposed approach is significantly higher than that of the existing methods. In addition, it has a strong anti-noise ability.
Support Vector Machines (SVMs) have achieved significant success in the field of power transformer fault diagnosis. However, challenges such as determining SVM hyperparameters and their suitability for binary classification still exist. This paper proposes a novel method for power transformer fault diagnosis, called ECOC-WSO-SVM, which utilizes a White Shark Optimizer (WSO) and error correcting output codes to optimize SVMs. First, t-distributed Stochastic Neighbor Embedding (t-SNE) is employed to reduce the dimensionality of Dissolved Gas Analysis (DGA) features constructed using the correlation ratio method, from 26 dimensions. In addition, to effectively solve the hyperparameters of SVMs, a multi-strategy fusion method is proposed to improve the WSO, incorporating tent chaos initialization, elite opposite learning, and selection strategies, forming TEWSO, and its superior optimization performance is validated using IEEE CEC2021 test functions. Furthermore, to address the limitations of SVMs as a binary classifier, an error correcting output code fusion SVM is introduced, thus constructing a multi-class SVM model. Finally, the diagnostic performance of the ECOC-TEWSO-SVM model is validated using real-world data. Results demonstrate that the proposed model exhibits the best diagnostic performance compared to traditional models and those in the literature, thereby proving the significance and effectiveness of the proposed model.
The paper addresses the overlooked interaction between power-to-gas (P2G) devices and carbon capture and storage (CCS) equipment, along with the stepwise carbon trading mechanism in the context of current multi-park integrated energy microgrids (IEMGs). Additionally, it covers the economic and coordinated low-carbon operation issues in multi-park IEMGs under the carbon trading system. It proposes a multi-park IEMG low-carbon operation strategy based on the synchronous Alternating Direction Method of Multipliers (ADMM) algorithm. The algorithm first enables the distribution of cost relationships among multi-park IEMGs. Then, using a method that combines a CCS device with a P2G unit in line with the tiered carbon trading scheme, it expands on the model of single IEMGs managing thermal, electrical, and refrigeration energy. Finally, the comparison of simulation cases proves that the proposed strategy significantly reduces the external energy dependence while keeping the total cost of the users unchanged, and the cost of interaction with the external grid is reduced by 56.64%, the gas cost is reduced by 27.78%, and the carbon emission cost is reduced by 29.54% by joining the stepped carbon trading mechanism.
Photovoltaic (PV) power generation is the main aspect of new energy power generation, and it is an important means to achieve the goal of carbon neutrality. When the PV system is connected to the grid, the nonlinear load of the grid will affect the power quality and consume reactive power. This paper proposes a PV power generation grid‐connected system to improve power quality, with an active power filter (APF) function. Through the maximum power point tracking (MPPT) method, PV power generation can operate at the maximum power point and play the function of harmonic and reactive power compensation at the load side. To improve the dynamic performance of the grid‐connected PV system and harmonic compensation simultaneously, multistep finite control set model predictive control (FCS‐MPC) is adopted for the grid‐connected module. The whole system does not need additional equipment, as it plays the role of two devices and effectively reduces the input cost. In this paper, the proposed structure and multistep FCS‐MPC are verified in MATLAB/Simulink. The results show that the system injects the maximum power into the power grid at the same time when the load changes and compensates the harmonic generated by the nonlinear load of the power grid so that the total harmonic distortion of the power grid can meet the operation standard, and the system has good dynamic performance and steady‐state performance.