Jim Huggett

Dr. Jim Huggett


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2009 in Clinical Chemistry
Verified
Journal Article
Open access
PDF file
SBStephen Bustin
Stephen Bustin
VBVladimir Benes
Vladimir Benes
JGJeremy A Garson
Jeremy A Garson
JHJan Hellemans
Jan Hellemans
JHJim Huggett
Jim Huggett
CWCarl T Wittwer
Carl T Wittwer
Background: Currently, a lack of consensus exists on how best to perform and interpret quantitative real-time PCR (qPCR) experiments. The problem is exacerbated by a lack of sufficient experimental detail in many publications, which impedes a reader’s ability to evaluate critically the quality of the results presented or to repeat the experiments.Content: The Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines target the reliability of results to help ensure the integrity of the scientific literature, promote consistency between laboratories, and increase experimental transparency. MIQE is a set of guidelines that describe the minimum information necessary for evaluating qPCR experiments. Included is a checklist to accompany the initial submission of a manuscript to the publisher. By providing all relevant experimental conditions and assay characteristics, reviewers can assess the validity of the protocols used. Full disclosure of all reagents, sequences, and analysis methods is necessary to enable other investigators to reproduce results. MIQE details should be published either in abbreviated form or as an online supplement.Summary: Following these guidelines will encourage better experimental practice, allowing more reliable and unequivocal interpretation of qPCR results.

7 April 2005 in Genes & Immunity
Verified
Journal Article
Open access
PDF file
JHJim Huggett
Jim Huggett
KDK Dheda
K Dheda
SBStephen Bustin
Stephen Bustin
AZAlimuddin Zumla
Alimuddin Zumla
Real-time RT-PCR has become a common technique, no longer limited to specialist core facilities. It is in many cases the only method for measuring mRNA levels of vivo low copy number targets of interest for which alternative assays either do not exist or lack the required sensitivity. Benefits of this procedure over conventional methods for measuring RNA include its sensitivity, large dynamic range, the potential for high throughout as well as accurate quantification. To achieve this, however, appropriate normalisation strategies are required to control for experimental error introduced during the multistage process required to extract and process the RNA. There are many strategies that can be chosen; these include normalisation to sample size, total RNA and the popular practice of measuring an internal reference or housekeeping gene. However, these methods are frequently applied without appropriate validation. In this review we discuss the relative merits of different normalisation strategies and suggest a method of validation that will enable the measurement of biologically meaningful results.

1 July 2004 in BioTechniques
Verified
Journal Article
Open access
KDKeertan Dheda
Keertan Dheda
JHJim Huggett
Jim Huggett
SBStephen Bustin
Stephen Bustin
MJMargaret A. Johnson
Margaret A. Johnson
GRGraham Rook
Graham Rook
AZAlimuddin Zumla
Alimuddin Zumla
Analysis of RNA expression using techniques like real-time PCR has traditionally used reference or housekeeping genes to control for error between samples. This practice is being questioned as it b... Normalizing RNA Expression Normalizing RNA levels to internal or housekeeping reference standards is widely used to control for sample error when measuring RNA expression levels. Choice of an appro...

1 June 2013 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
JHJim Huggett
Jim Huggett
CFCarole A Foy
Carole A Foy
VBVladimir Benes
Vladimir Benes
KEKerry Emslie
Kerry Emslie
JGJeremy A Garson
Jeremy A Garson
SBStephen Bustin
Stephen Bustin
There is growing interest in digital PCR (dPCR) because technological progress makes it a practical and increasingly affordable technology. dPCR allows the precise quantification of nucleic acids, facilitating the measurement of small percentage differences and quantification of rare variants. dPCR may also be more reproducible and less susceptible to inhibition than quantitative real-time PCR (qPCR). Consequently, dPCR has the potential to have a substantial impact on research as well as diagnostic applications. However, as with qPCR, the ability to perform robust meaningful experiments requires careful design and adequate controls. To assist independent evaluation of experimental data, comprehensive disclosure of all relevant experimental details is required. To facilitate this process we present the Minimum Information for Publication of Quantitative Digital PCR Experiments guidelines. This report addresses known requirements for dPCR that have already been identified during this early stage of its development and commercial implementation. Adoption of these guidelines by the scientific community will help to standardize experimental protocols, maximize efficient utilization of resources, and enhance the impact of this promising new technology.

1 September 2005 in Analytical Biochemistry
Verified
Journal Article
Closed access
KDK. Dheda
K. Dheda
JHJim Huggett
Jim Huggett
JCJ.S. Chang
J.S. Chang
LKL.U. Kim
L.U. Kim
SBStephen Bustin
Stephen Bustin
AZAlimuddin Zumla
Alimuddin Zumla

1 January 2010 in BMC Molecular Biology
Verified
Journal Article
Open access
PDF file
SBStephen Bustin
Stephen Bustin
JBJean-François Beaulieu
Jean-François Beaulieu
JHJim Huggett
Jim Huggett
RJRolf Jaggi
Rolf Jaggi
Frederick KibengeFrederick Kibenge
Frederick Kibenge
STStefan Toegel
Stefan Toegel
The conclusions of thousands of peer-reviewed publications rely on data obtained using fluorescence-based quantitative real-time PCR technology. However, the inadequate reporting of experimental detail, combined with the frequent use of flawed protocols is leading to the publication of papers that may not be technically appropriate. We take the view that this problem requires the delineation of a more transparent and comprehensive reporting policy from scientific journals. This editorial aims to provide practical guidance for the incorporation of absolute minimum standards encompassing the key assay parameters for accurate design, documentation and reporting of qPCR experiments (MIQE précis) and guidance on the publication of pure 'reference gene' articles.