Olga Karandaeva

Olga Karandaeva


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2020 in Machines
Verified
Journal Article
Open access
PDF file
Marina SamodurovaMarina Samodurova
Marina Samodurova
OKOlga Karandaeva
Olga Karandaeva
Vadim KhramshinVadim Khramshin
Vadim Khramshin
ILIvan V. Liubimov
Ivan V. Liubimov
Making “digital twins” for rolling processes and mill equipment should begin with the development of mathematical models of the deformation zone. The deformation zone of two-high flat mill rolling have been studied in detail, relevant models are available in many academic papers. However, the same cannot be said about the most complex deformation zones in stands with multi-roll gauge. Therefore, the task of their reliable mathematical description is of immediate interest. The development of mathematical models is necessary for the design of new wire mills and rolling-drawing units. The combination of rolling in stands with multi-roll gauge and drawing is a promising direction in the production of wire from difficult-to-form steels and alloys. Digital models for pressure-based metal treatment are also necessary for calculating the rolling-mill power parameters during the development of new assortments at the operating mills. The models of deformation zones present the basis for developing the multivariable control systems of process conditions of continuous mills. This research is devoted to the study of the deformation zone and the development of a procedure for calculating the power parameters of rolling in a stand with four-roll passes. The solution of these challenges is given using the example of an operating five-stand wire mill. The authors analysed the known analytical dependencies for calculating the rolling mill force and torque. A mathematical model of the deformation zone and a program for calculating the power parameters have been developed. The paper compares the results obtained from calculations based on analytical dependence and on modelling. A comparison with the experimental parameters obtained at the mill is given. The authors assess the feasibility of using the known formulas and analyse the impact of the front and rear tensions on the power parameters of rolling mill. The problem of developing an automatic tension control system for continuous mills with multi-roll groove is substantiated.

13 December 2019 in Machines
Verified
Journal Article
Open access
PDF file
OKOlga Karandaeva
Olga Karandaeva
IYIvan A. Yakimov
Ivan A. Yakimov
AFAlexandra A. Filimonova
Alexandra A. Filimonova
EGEkaterina Gartlib
Ekaterina Gartlib
IYIgor M. Yachikov
Igor M. Yachikov
The article is dedicated to research of the technical state of a furnace transformer. The study was conducted on the basis of statistical processing of continuously measured parameters of partial discharges (PD). The authors characterize the causes of PD occurrence and their impact on the insulation condition. The article provides information on the on-line monitoring system applied at high-voltage transformers of superpowered arc steel-melting furnaces and ladle furnaces at metallurgical plants. The system implements (among other methods) the method of diagnosing the insulation state by means of mathematical processing of PD parameters. Continuously measured values are apparent charge and the parameter called partial discharge intensity (PDI) characterizing the power and intensity of PD. The authors studied the parameter trends and conducted the statistical processing of the measurements results. In addition, the authors give the rationale for the application of the parameter “reciprocal stochastic connection force” between the PD amplitude and PDI as a generalized criterion of the insulation state and failure localization. The article compares trends of power and PD amplitude at various transformer technical states (before and after unscheduled repair). The authors confirm the possibility to diagnose emerging defects by comparing the correlation factors of these dependences. An example of defect occurrence and its location is provided. As a result, the authors manage to prove the efficiency of the proposed method of analysis of the high-voltage transformer state. This research has produced an integrated approach that enables on-the-go technical diagnosis, fault localization, and accident prevention. The key product of this research is a transformer diagnosis method based on processing the data of online PD monitoring. To that end, the proposed method uses statistical toolkits available for a PC. The areas for further prospective research are outlined. The authors also give recommendations on a more extensive application of the developed method.

1 January 2018 in Bulletin of the South Ural State University. Series ‘Metallurgy’
Verified
Journal Article
Open access
PDF file
NUNosov Magnitogorsk State Technical University
Nosov Magnitogorsk State Technical University
IYI. Yachikov
I. Yachikov
АРА. А. Радионов
А. А. Радионов
SUSouth Ural State University
South Ural State University
AKA. Karandayev
A. Karandayev
OKOlga Karandaeva
Olga Karandaeva
СРАВНЕНИЕ ЭФФЕКТИВНОСТИ РАДИАТОРОВ ВОЗДУШНОГО ОХЛАЖДЕНИЯ ДЛЯ ПОДОВЫХ ЭЛЕКТРОДОВ ДУГОВОЙ ПЕЧИ ПОСТОЯННОГО ТОКА