William King III

Mr. William King III

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2021 in Polymers
Verified
Journal Article
Open access
PDF file
WIWilliam King III
William King III
Gary BowlinGary Bowlin
Gary Bowlin
Near-field electrospinning (NFES) and melt electrowriting (MEW) are the process of extruding a fiber due to the force exerted by an electric field and collecting the fiber before bending instabilities occur. When paired with precise relative motion between the polymer source and the collector, a fiber can be directly written as dictated by preprogrammed geometry. As a result, this precise fiber control results in another dimension of scaffold tailorability for biomedical applications. In this review, biomedically relevant polymers that to date have manufactured fibers by NFES/MEW are explored and the present limitations in direct fiber writing of standardization in published setup details, fiber write throughput, and increased ease in the creation of complex scaffold geometries are discussed.

29 March 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
WIWilliam King III
William King III
Gary BowlinGary Bowlin
Gary Bowlin

18 December 2019 in Polymers
Verified
Journal Article
Open access
PDF file
WIWilliam King III
William King III
YGYvonne Gillespie
Yvonne Gillespie
KGKeaton Gilbert
Keaton Gilbert
Gary BowlinGary Bowlin
Gary Bowlin
Electrospinning is a popular method for creating random, non-woven fibrous templates for biomedical applications, and a subtype technique termed near-field electrospinning (NFES) was devised by reducing the air gap distance to millimeters. This decreased working distance paired with precise translational motion between the fiber source and collector allows for the direct writing of fibers. We demonstrate a near-field electrospinning device designed from a MakerFarm Prusa i3v three-dimensional (3D) printer to write polydioxanone (PDO) microfibers. PDO fiber diameters were characterized over the processing parameters: Air gap, polymer concentration, translational velocity, needle gauge, and applied voltage. Fiber crystallinity and individual fiber uniformity were evaluated for the polymer concentration and translational fiber deposition velocity. Fiber stacking was evaluated for the creation of 3D templates to guide the alignment of human gingival fibroblasts. The fiber diameters correlated positively with polymer concentration, applied voltage, and needle gauge; and inversely correlated with translational velocity and air gap distance. Individual fiber diameter variability decreases, and crystallinity increases with increasing translational fiber deposition velocity. These data resulted in the creation of tailored PDO 3D templates, which guided the alignment of primary human fibroblast cells. Together, these results suggest that NFES of PDO can be scaled to create precise geometries with tailored fiber diameters for biomedical applications.

3 September 2021 in Biomedical Materials
Verified
Journal Article
Closed access
WIWilliam King III
William King III
GBGary L Bowlin
Gary L Bowlin
Near-field electrospinning (NFES) is a direct fiber writing sub-technique derived from traditional electrospinning (TES) by reducing the air gap distance to the magnitude of millimeters. In this paper, we demonstrate a NFES device designed from a commercial 3D printer to semi-stably write polydioxanone (PDO) microfibers. The print head was then programmed to translate in a stacking grid pattern, which resulted in a scaffold with highly aligned grid fibers that were intercalated with low density, random fibers. As the switching process can be considered random, increasing the grid size results in both a lower density of fibers in the center of each grid cell as well as a lower density of ‘rebar-like’ stacked fibers. These scaffolds resulted in tailorable as well as greater surface pore sizes as given by scanning electron micrographs and 3D permeability as indicated by fluorescent microsphere filtration compared to TES scaffolds of the same fiber diameter. Furthermore, ultimate tensile strength, percent elongation, yield stress, yield elongation, and Young’s modulus were all tailorable compared to the static TES scaffold characterization. Lastly, the innate immune response of neutrophil extracellular traps was attenuated on NFES scaffolds compared to TES scaffolds. These results suggest that this novel NFES scaffold architecture of PDO can be highly tailored as a function of programming for a variety of biomedical and tissue engineering applications.

20 November 2025 in Journal of the American College of Radiology
Verified
Journal Article
Closed access
YNYee Seng Ng
Yee Seng Ng
MKMohammed M. Kanani
Mohammed M. Kanani
WIWilliam King III
William King III
ZMZachary D. Miller
Zachary D. Miller
LBLauryn Brown
Lauryn Brown
NCNathan M. Cross
Nathan M. Cross