Xiang Zeng

Dr. Xiang Zeng

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
XZXiang Zeng
Xiang Zeng
JHJingsi Huo
Jingsi Huo
HWHaitao Wang
Haitao Wang
ZWZhan Wang
Zhan Wang
Mohamed ElchalakaniMohamed Elchalakani
Mohamed Elchalakani
The strain rate effect of engineering materials should be considered in the assessment of the performance of reinforced concrete (RC) structures under extreme dynamic loads such as blast and impact. However, the strain rate behavior of 500 MPa-grade anti-earthquake hot-rolled high-strength ribbed bar (HRB500E), used in critical RC members to improve the anti-earthquake performance, has not been investigated and reported in the open literature. That restricts its application in RC structures subjected to extreme dynamic loads. In this paper, dynamic tensile tests of HRB500E steel were conducted using an electromechanical universal testing machine and a servo-hydraulic high-speed testing machine. The stress–strain curves at strain rates ranging from 0.00025 to 550 s−1 were obtained where HRB500E steel was found significantly sensitive to strain rate. Existing formulations to evaluate the dynamic increase factor for yield stress (DIFy) are found to be not suitable for HRB500E steel, thus the widely used Cowper–Symonds and Malvar models for predicting the DIFy were modified based on the test results. Furthermore, the parameter of the Mander material model for describing engineering stress–strain relationship was also calibrated. Finally, the Johnson-Cook and proposed constitutive models for the true stress–strain relationship were examined. The proposed constitutive model can provide better prediction accuracy for yield stress than the Johnson-Cook model.

15 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
XZXiang Zeng
Xiang Zeng
WWWanbo Wu
Wanbo Wu
JZJuan Zou
Juan Zou
Mohamed ElchalakaniMohamed Elchalakani
Mohamed Elchalakani
High-strength steel has been increasingly applied to engineering structures and inevitably faces fire risks. The equivalent stress-plastic strain (σeq− εeqp) curves of steel at elevated temperatures are indispensable if a refined finite element model is used to investigate the response of steel members and structures under fire. If the tensile deformation of steel is considerable, the σeq− εeqp curves at elevated temperatures are required to consider the strain-hardening behavior during the post-necking phase. However, there is little research on the topic. Based on the engineering stress-strain curves of Q890 high-strength steel in a uniaxial tension experiment at elevated temperatures, the σeq−εeqp curves before necking are determined using theoretical formulations. An inverse method based on finite element analysis is used to determine the σeq− εeqp curves during the post-necking phase. The characteristics of σeq−εeqp curves, including the full-range strain hardening behavior at different temperatures, are discussed. An equivalent stress-plastic strain model of Q890 steel at elevated temperature is proposed, which is consistent with the σeq−εeqp curves. The constitutive model is further verified by comparing the finite element analysis and test results.

16 September 2024 in Buildings
Verified
Journal Article
Open access
PDF file
JZJian Zou
Jian Zou
BCBaozhu Cao
Baozhu Cao
XZXiang Zeng
Xiang Zeng
CZChuan Yu Zhang
Chuan Yu Zhang
To study the lateral performance of a cold-formed steel–concrete insulation sandwich panel composite wall, two full-scale specimens with different arrangements were designed. The specimens underwent cyclic loading tests to examine the failure characteristics of the composite wall, and lateral performance aspects such as the experimental hysteresis curve, skeleton curve, and characteristic value of the whole loading process were acquired. The experimental results indicate that the failure of the composite wall system was primarily caused by the failure of the connection; the overall lateral performance of composite walls with one wall panel at the bottom and two wall panels at the top (W1) was superior to that of composite walls with two wall panels at the bottom and one wall panel at the top (W2). When loaded to an inter-story drift ratio of 1/300, the composite wall did not exhibit any significant damage. A finite element (FE) model was developed and validated by the experiments. Factors affecting the shear bearing capacity were analyzed based on the FE model, including the yield strength of diagonal braces, the thickness of the diagonal braces, the arrangement pattern of the wall panels, the dimensions of the wall panels, and the strength of the connection of the L-shaped connector and the flat connector. The FE results show that all these factors can influence the lateral performance of the composite wall.

6 May 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
XZXiang Zeng
Xiang Zeng
CNChunzhen Ning
Chunzhen Ning
WZWeizhe Zeng
Weizhe Zeng
Bin XuBin Xu
Bin Xu

9 January 2026 in Structures
Verified
Journal Article
Closed access
XZXiang Zeng
Xiang Zeng
SSShao-Hua Song
Shao-Hua Song
SLShan Li
Shan Li
ZLZhe Li
Zhe Li
TLTze Ming Leung
Tze Ming Leung

14 May 2026 in Engineering Structures
Verified
Journal Article
Open access
XZXiang Zeng
Xiang Zeng
GCGuozhi Chen
Guozhi Chen
Zhongxing WangZhongxing Wang
Zhongxing Wang
BSBo Shan
Bo Shan
ZTZhong Tao
Zhong Tao