Anjun Zhao

Anjun Zhao


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2023 in Renewable Energy
Verified
Journal Article
Closed access
AZAnjun Zhao
Anjun Zhao
YJYang Jiao
Yang Jiao
WQWei Quan
Wei Quan
YCYiren Chen
Yiren Chen

22 September 2019 in Journal of Control Science and Engineering
Verified
Journal Article
Open access
PDF file
JYJunQi Yu
JunQi Yu
WJWenQiang Jing
WenQiang Jing
AZAnjun Zhao
Anjun Zhao
YRYanHuan Ren
YanHuan Ren
MZMeng Zhou
Meng Zhou
A combination of JMP, PSO-BP neural network, and Markov chain which aims at the low correlation between input and output data and the error of prediction model in the PSO-BP neural network prediction model is proposed. First, the JMP data processing software is used to process the input data and eliminate the samples with low coupling degree. Then, obtaining the cooling load prediction results relies on the training from the PSO-BP neural network. Finally, the final prediction results will be generated by eliminating the random errors using the Markov chain. The results show that the combination of the prediction methods has higher prediction accuracy and conforms to the change rule of the cooling load in shopping malls. Besides, the combination fits the actual application requirements as well.

1 March 2022 in Journal of Asian Architecture and Building Engineering
Verified
Journal Article
Open access
ZMZhou Meng
Zhou Meng
YJYu Junqi
Yu Junqi
AZAnjun Zhao
Anjun Zhao
Central heating system faults affect building energy consumption and indoor thermal comfort significantly. To aim at the balance between thermal comfortable and energy-saving of the heating system for high-rise residential buildings, this paper proposes a method for the central heating system of high-rise residential buildings based on distributed model predictive control. The method analyzes the coupling factors between adjacent rooms’ temperature. Based on the state space method, a multivariable indoor temperature model is established and verified. The distributed model predictive control method is used to control and optimize the indoor temperature, and the load distribution of the circulating water pump in the heat exchange station is optimized according to the predicted heat demand. The results demonstrate that the indoor temperature after distributed model predictive control can stable near the set value. Compared with the centralized control methods, the proposed methodology can reduce energy consumption by 14.28%. Meanwhile, the efficiency of water pumps is increased by 16.74% after using the distributed control strategy.

3 April 2019
Verified
Book Chapter
Closed access
PDF file
AZAnjun Zhao
Anjun Zhao
MZMeng Zhou
Meng Zhou
JYJunqi Yu
Junqi Yu
JZJunlin Zhang
Junlin Zhang
XYXiong Yang
Xiong Yang

1 May 2021 in JOURNAL OF SHENZHEN UNIVERSITY SCIENCE AND ENGINEERING
Verified
Journal Article
Closed access
JYJunqi Yu
Junqi Yu
JWJiali Wang
Jiali Wang
AZAnjun Zhao
Anjun Zhao
YXYunfei Xie
Yunfei Xie
TRTong Ran
Tong Ran
ZZZehua Zhao
Zehua Zhao
In order to improve the accuracy of electrical load forecasting for large public buildings, we propose a forecasting model for the short-term load of large public buildings based on affinity propagation (AP) similar days selection and the fusion improvement seeker optimization algorithm-radial basis function (FISOA-RBF) neural network by considering the weather information, date type and other influencing factors. In order to overcome the influence of external environment on the accuracy of building electrical load forecasting, AP algorithm is used to select similar days of short-term electrical load. The structural parameters of RBF neural network are optimized by FISOA which uses the fusion improvement theory to further improve the prediction accuracy and the learning speed of RBF neural network. Finally, the similar daily load data are used to train an optimized FISOA-RBF to predict the short-term electrical load of buildings. In order to validate the effectiveness of the proposed model, the exhaustive experiments are conducted in comparison with RBF, PSO-RBF and SOA-RBF methods. The experimental results indicate that the proposed model outperforms the other models: the mean absolute percentage error (MAPE) is reduced by 93.05%, 83.60% and 71.13%, and the average prediction speed is increased by 54.34%, 39.25% and 23.96%, and thus demonstrate that AP-FISOA-RBF model in prediction accuracy and speed of prediction performance is better than other three RBF-based methods.

3 April 2019
Verified
Book Chapter
Closed access
PDF file
YJYU Jun-qi
YU Jun-qi
XQXuegen Qian
Xuegen Qian
AZAnjun Zhao
Anjun Zhao
SWShiqiang Wang
Shiqiang Wang
QLQite Liu
Qite Liu