This study determined natural and artificial radionuclide concentrations to evaluate natural radioactivity and health risk levels of nine travertines in the Yaprakhisar and Balkayası regions in Turkey. The samples coded B1-M, B2, B5, B7, B8, and B10 represent waste derived from the Yaprakhisar travertines, as well as samples T5-M, T12, and Z1 travertines derived from Balkayası. The levels of natural and artificial radionuclide concentrations (232Th, 40K, and 137Cs) were measured using a high-purity germanium (HpGe) detector system. The travertine activity ranged from 2.09 to 12.07 Bq kg−1 for 232Th, 4.21 to 13.41 Bq kg−1 for 40K, and 0.42–3.26 Bq kg−1 for 137Cs. The results showed that the activity concentration values for 232Th, 40K, and 137Cs were coherent with the travertine analysis results in the UNSCEAR, 2000; 2008 publications. The values obtained were lower than the average values in the UNSEAR reports. The radiological hazard parameters calculated in this study were absorbed gamma dose rate (D), radium equivalent activity (Raeq), annual gonadal dose equivalent (AGDE), exposure dose (ER), total annual effective dose (AEDEtotal), excess lifetime cancer risk (ELCRtotal), gamma representative level (GRL), internal hazard index (Hin) and external hazard index (Hex).
In this study, radiation shielding performance of pure Lead Sheets were carried out by using new X-ray transmission set up. Diagnostic x-rays from 50 kVp to 110 kVp were applied in the experiments. Experimental set up was designed according to narrow beam geometry conditions of IEC 61331-1:2014 standard. Pure Lead sheets (99.99 % purity) having different thicknesses (0.05-0.5 mm, 0.05 mm steps), were performed against diagnostic x-rays. Radiation attenuation percentages were carried out for each xray peak tube voltages from 50 kVp to 110 kVp with 10 kVp steps. Radiation shielding percentages of the lead sheet for the studied x-ray peak tube voltage were in the range of 50.8-99.7 %. X-ray shielding percentages of commonly used Lead thicknesses were compared with the literature. The radiation shielding percentages of the samples were in a good agreement with the literature. The average of difference percentages of the study with the literature was 0.76 %. 0.25, 0.35 and 0.5 mm Lead thicknesses have 90.3 % , 94.7 % and 97.2 % shielding performance against 90 kVp, respectively.
This study focused on the x-ray radiation attenuation properties of spark plasma sintered boron carbide-zirconium diboride (B4C-ZrB2) composites against diagnostic x-rays. The ZrB2 amount ranged from 0 to 15 vol%. Diagnostic x-rays were applied using the tube voltages ranging from 50 to 110 kV in 10 kV increments. The linear and mass attenuation coefficients, as well as the Half-Value Layers (HVLs) and Tenth-Value Layers (TVLs), were determined for all applied tube voltages. Fast neutron removal cross sections (FNRCSs) were also figured out for studied B4C-ZrB2 composites. It has been revealed that the addition of ZrB2 to B4C enhanced not only the x-ray attenuation capability across all applied tube voltages but also increased FNRCS values. In addition, Radiation attenuation ratios (RARs) and lead equivalent thickness (PbE) values were calculated for all samples. Increasing the amount of ZrB2 in the samples caused higher radiation attenuation coefficients. While one cm thick monolithic B4C had an average PbE of 0.019 mm, one cm thick B4C- %15 ZrB2 had an average PbE of 0.404 mm, which indicates that BZ15 demonstrated approximately 25 times better radiation attenuation performance than monolithic B4C. In addition, a 1 cm thick BZ15 composite provides at least 0.35 mm PbE radiation shielding performance for the studied diagnostic x-rays, which is equivalent to approximately 17.5% of the 2 mm Pb sheets typically used in x-ray protection applications. These findings have the potential to minimize Pb usage, thereby supporting sustainable alternatives. In conclusion, ZrB2-added B4C materials exhibit superior radiation attenuation properties compared to monolithic B4C.