Davide Di Giuseppe

Dr. Davide Di Giuseppe

Università di Roma Tor Vergata
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Cell Reports
Verified
Journal Article
Open access
MNMarie Nguyen
Marie Nguyen
ANAdele De Ninno
Adele De Ninno
AMArianna Mencattini
Arianna Mencattini
FMFanny Mermet-Meillon
Fanny Mermet-Meillon
GFGiulia Fornabaio
Giulia Fornabaio
MPMaria Carla Parrini
Maria Carla Parrini
A major challenge in cancer research is the complexity of the tumor microenvironment, which includes the host immunological setting. Inspired by the emerging technology of organ-on-chip, we achieved 3D co-cultures in microfluidic devices (integrating four cell populations: cancer, immune, endothelial, and fibroblasts) to reconstitute ex vivo a human tumor ecosystem (HER2+ breast cancer). We visualized and quantified the complex dynamics of this tumor-on-chip, in the absence or in the presence of the drug trastuzumab (Herceptin), a targeted antibody therapy directed against the HER2 receptor. We uncovered the capacity of the drug trastuzumab to specifically promote long cancer-immune interactions (>50 min), recapitulating an anti-tumoral ADCC (antibody-dependent cell-mediated cytotoxicity) immune response. Cancer-associated fibroblasts (CAFs) antagonized the effects of trastuzumab. These observations constitute a proof of concept that tumors-on-chip are powerful platforms to study ex vivo immunocompetent tumor microenvironments, to characterize ecosystem-level drug responses, and to dissect the roles of stromal components.

6 October 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EBElena Biselli
Elena Biselli
EAElena Agliari
Elena Agliari
ABAdriano Barra
Adriano Barra
FBFrancesca Romana Bertani
Francesca Romana Bertani
AGAnnamaria Gerardino
Annamaria Gerardino
LBLuca Businaro
Luca Businaro
In this paper we discuss the applicability of numerical descriptors and statistical physics concepts to characterize complex biological systems observed at microscopic level through organ on chip approach. To this end, we employ data collected on a microfluidic platform in which leukocytes can move through suitably built channels toward their target. Leukocyte behavior is recorded by standard time lapse imaging. In particular, we analyze three groups of human peripheral blood mononuclear cells (PBMC): heterozygous mutants (in which only one copy of the FPR1 gene is normal), homozygous mutants (in which both alleles encoding FPR1 are loss-of-function variants) and cells from ‘wild type’ donors (with normal expression of FPR1). We characterize the migration of these cells providing a quantitative confirmation of the essential role of FPR1 in cancer chemotherapy response. Indeed wild type PBMC perform biased random walks toward chemotherapy-treated cancer cells establishing persistent interactions with them. Conversely, heterozygous mutants present a weaker bias in their motion and homozygous mutants perform rather uncorrelated random walks, both failing to engage with their targets. We next focus on wild type cells and study the interactions of leukocytes with cancerous cells developing a novel heuristic procedure, inspired by Lyapunov stability in dynamical systems.

16 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
RPRoberto Paoli
Roberto Paoli
DGDavide Di Giuseppe
Davide Di Giuseppe
MBMaider Badiola-Mateos
Maider Badiola-Mateos
Eugenio MartinelliEugenio Martinelli
Eugenio Martinelli
MMMaria José Lopez Martinez
Maria José Lopez Martinez
Josep Samitier MartíJosep Samitier Martí
Josep Samitier Martí
Microfabrication and Polydimethylsiloxane (PDMS) soft-lithography techniques became popular for microfluidic prototyping at the lab, but even after protocol optimization, fabrication is yet a long, laborious process and partly user-dependent. Furthermore, the time and money required for the master fabrication process, necessary at any design upgrade, is still elevated. Digital Manufacturing (DM) and Rapid-Prototyping (RP) for microfluidics applications arise as a solution to this and other limitations of photo and soft-lithography fabrication techniques. Particularly for this paper, we will focus on the use of subtractive DM techniques for Organ-on-a-Chip (OoC) applications. Main available thermoplastics for microfluidics are suggested as material choices for device fabrication. The aim of this review is to explore DM and RP technologies for fabrication of an OoC with an embedded membrane after the evaluation of the main limitations of PDMS soft-lithography strategy. Different material options are also reviewed, as well as various bonding strategies. Finally, a new functional OoC device is showed, defining protocols for its fabrication in Cyclic Olefin Polymer (COP) using two different RP technologies. Different cells are seeded in both sides of the membrane as a proof of concept to test the optical and fluidic properties of the device.

1 May 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MCM. C. Comes
M. C. Comes
PCP. Casti
P. Casti
Arianna MencattiniArianna Mencattini
Arianna Mencattini
DGDavide Di Giuseppe
Davide Di Giuseppe
FMF. Mermet-Meillon
F. Mermet-Meillon
Eugenio MartinelliEugenio Martinelli
Eugenio Martinelli
Cell-cell interactions are an observable manifestation of underlying complex biological processes occurring in response to diversified biochemical stimuli. Recent experiments with microfluidic devices and live cell imaging show that it is possible to characterize cell kinematics via computerized algorithms and unravel the effects of targeted therapies. We study the influence of spatial and temporal resolutions of time-lapse videos on motility and interaction descriptors with computational models that mimic the interaction dynamics among cells. We show that the experimental set-up of time-lapse microscopy has a direct impact on the cell tracking algorithm and on the derived numerical descriptors. We also show that, when comparing kinematic descriptors in two diverse experimental conditions, too low resolutions may alter the descriptors’ discriminative power, and so the statistical significance of the difference between the two compared distributions. The conclusions derived from the computational models were experimentally confirmed by a series of video-microscopy acquisitions of co-cultures of unlabelled human cancer and immune cells embedded in 3D collagen gels within microfluidic devices. We argue that the experimental protocol of acquisition should be adapted to the specific kind of analysis involved and to the chosen descriptors in order to derive reliable conclusions and avoid biasing the interpretation of results.

8 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ACAlexandro Catini
Alexandro Catini
LPLeonardo Papale
Leonardo Papale
RCRosamaria Capuano
Rosamaria Capuano
VPValentina Pasqualetti
Valentina Pasqualetti
DGDavide Di Giuseppe
Davide Di Giuseppe
Corrado Di NataleCorrado Di Natale
Corrado Di Natale
The appraisal of stress in plants is of great relevance in agriculture and any time the transport of living plants is involved. Wireless sensor networks (WSNs) are an optimal solution to simultaneously monitor a large number of plants in a mostly automatic way. A number of sensors are readily available to monitor indicators that are likely related to stress. The most common of them include the levels of total volatile compounds and CO2 together with common physical parameters such as temperature, relative humidity, and illumination, which are known to affect plants’ behavior. Recent progress in microsensors and communication technologies, such as the LoRa protocol, makes it possible to design sensor nodes of high sensitivity where power consumption, transmitting distances, and costs are optimized. In this paper, the design of a WSN dedicated to plant stress monitoring is described. The nodes have been tested on European privet (Ligustrum Jonandrum) kept in completely different conditions in order to induce opposite level of stress. The results confirmed the relationship between the release of total Volatile Organic Compounds (VOCs) and the environmental conditions. A machine learning model based on recursive neural networks demonstrates that total VOCs can be estimated from the measure of the environmental parameters.

6 February 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
DGDavide Di Giuseppe
Davide Di Giuseppe
FCFrancesca Corsi
Francesca Corsi
Arianna MencattiniArianna Mencattini
Arianna Mencattini
MCMaria Colomba Comes
Maria Colomba Comes
PCPaola Casti
Paola Casti
EMEugenio Martinelli
Eugenio Martinelli
Objective: The ability of cells to collectively move is essential in various biological contexts including cancer metastasis. In this paper, we propose an automatic video analysis tool to correlate the cell movement inhibition with replication block induced by dose-dependent chemotherapy administration. Methods: The novel approach combines individual and collective cell kinematic analysis performed over time-lapse microscopy video frames. Cells are first localized and tracked, and then kinematic descriptors are extracted for each track. Selective track identification is performed assuming diversified cell roles within the same cluster (spontaneously forming groups of cells), and finally individual results are grouped exploiting consensus of coordinated motility within cell clusters. Results: Recognition performance of three different experimental conditions (no drug, 0.5-5 mu M merged in the same condition, and 50 mu M) reached an average accuracy value of 88% over 958 different tracks collected in 36 clusters of diverse dimensions in eight independent experiments. Conclusion: An extensive application of this methodology could give a different point of view of the cancer mechanisms.