Bojan Stopar

Dr. Bojan Stopar

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2009 in Sensors
Verified
Journal Article
Open access
PDF file
RVRok Vezočnik
Rok Vezočnik
TATomaž Ambrožič
Tomaž Ambrožič
OSOskar Sterle
Oskar Sterle
GBGregor Bilban
Gregor Bilban
Norbert PfeiferNorbert Pfeifer
Norbert Pfeifer
BSBojan Stopar
Bojan Stopar
The paper presents a new methodology for high precision monitoring of deformations with a long term perspective using terrestrial laser scanning technology. In order to solve the problem of a stable reference system and to assure the high quality of possible position changes of point clouds, scanning is integrated with two complementary surveying techniques, i.e., high quality static GNSS positioning and precise tacheometry. The case study object where the proposed methodology was tested is a high pressure underground pipeline situated in an area which is geologically unstable.

12 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
VHVeton Hamza
Veton Hamza
BSBojan Stopar
Bojan Stopar
OSOskar Sterle
Oskar Sterle
Global Navigation Satellite System (GNSS) low-cost multi-frequency receivers are argued as an alternative to geodetic receivers for many applications. Calibrated low-cost antennas recently became available on the market making low-cost instruments more comparable with geodetic ones. The main goal of this research was to evaluate the noise of low-cost GNSS receivers, to compare the positioning quality from different types of low-cost antennas, and to analyze the positioning differences between low-cost and geodetic instruments. The results from a zero baseline test indicated that the u-blox multi-frequency receiver, namely, ZED-F9P, had low noise that was at the sub-millimeter level. To analyze the impact of the antennas in the obtained coordinates, a short baseline test was applied. Both tested uncalibrated antennas (Tallysman TW3882 and Survey) demonstrated satisfactory positioning performance. The Tallysman antenna was more accurate in the horizontal position determination, and the difference from the true value was only 0.1 mm; while, for the Survey antenna, the difference was 1.0 mm. For the ellipsoid height, the differences were 0.3 and 0.6 mm for the Survey and Tallysman antennas, respectively. The comparison of low-cost receivers with calibrated low-cost antennas (Survey Calibrated) and geodetic instruments proved better performance for the latter. The geodetic GNSS instruments were more accurate than the low-cost instruments, and the precision of the estimated coordinates from the geodetic network was also greater. Low-cost GNSS instruments were not at the same level as the geodetic ones; however, considering their cost, they demonstrated excellent performance that is sufficiently appropriate for various geodetic applications.

29 April 2015 in Journal of Geodesy
Verified
Journal Article
Closed access
PDF file
OSOskar Sterle
Oskar Sterle
BSBojan Stopar
Bojan Stopar
Polona Pavlovčič PrešerenPolona Pavlovčič Prešeren
Polona Pavlovčič Prešeren

5 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
VHVeton Hamza
Veton Hamza
BSBojan Stopar
Bojan Stopar
TATomaž Ambrožič
Tomaž Ambrožič
GTGoran Turk
Goran Turk
OSOskar Sterle
Oskar Sterle
Global Navigation Satellite System (GNSS) technology is widely used for geodetic monitoring purposes. However, in cases where a higher risk of receiver damage is expected, geodetic GNSS receivers may be considered too expensive to be used. As an alternative, low-cost GNSS receivers that are cheap, light, and prove to be of adequate quality over short baselines, are considered. The main goal of this research is to evaluate the positional precision of a multi-frequency low-cost instrument, namely, ZED-F9P with u-blox ANN-MB-00 antenna, and to investigate its potential for displacement detection. We determined the positional precision within static survey, and the displacement detection within dynamic survey. In both cases, two baselines were set, with the same rover point equipped with a low-cost GNSS instrument. The base point of the first baseline was observed with a geodetic GNSS instrument, whereas the second baseline was observed with a low-cost GNSS instrument. The results from static survey for both baselines showed comparable results for horizontal components; the precision was on a level of 2 mm or better. For the height component, the results show a better performance of low-cost instruments. This may be a consequence of unknown antenna calibration parameters for low-cost GNSS antenna, while statistically significant coordinates of rover points were obtained from both baselines. The difference was again more significant in the height component. For the displacement detection, a device was used that imposes controlled movements with sub-millimeter accuracy. Results, obtained on a basis of 30-min sessions, show that low-cost GNSS instruments can detect displacements from 10 mm upwards with a high level of reliability. On the other hand, low-cost instruments performed slightly worse as far as accuracy is concerned.

6 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
VHVeton Hamza
Veton Hamza
BSBojan Stopar
Bojan Stopar
OSOskar Sterle
Oskar Sterle
Polona Pavlovčič PrešerenPolona Pavlovčič Prešeren
Polona Pavlovčič Prešeren
Low-cost dual-frequency global navigation satellite system (GNSS) receivers have recently been tested in various positioning applications. Considering that these sensors can now provide high positioning accuracy at a lower cost, they can be considered an alternative to high-quality geodetic GNSS devices. The main objectives of this work were to analyze the differences between geodetic and low-cost calibrated antennas on the quality of observations from low-cost GNSS receivers and to evaluate the performance of low-cost GNSS devices in urban areas. In this study, a simple RTK2B V1 board u-blox ZED-F9P (Thalwil, Switzerland) was tested in combination with a low-cost calibrated and geodetic antenna in open-sky and adverse conditions in urban areas, while a high-quality geodetic GNSS device was used as a reference for comparison. The results of the observation quality check show that low-cost GNSS instruments have a lower carrier-to-noise ratio (C/N0) than geodetic instruments, especially in the urban areas where the difference is larger and in favor of the geodetic GNSS instruments. The root-mean-square error (RMSE) of the multipath error in the open sky is twice as high for low-cost as for geodetic instruments, while this difference is up to four times greater in urban areas. The use of a geodetic GNSS antenna does not show a significant improvement in the C/N0 and multipath of low-cost GNSS receivers. However, the ambiguity fix ratio is larger when geodetic antennas are used, with a difference of 1.5% and 18.4% for the open-sky and urban conditions, respectively. It should be noted that float solutions may become more evident when low-cost equipment is used, especially for short sessions and in urban areas with more multipath. In relative positioning mode, low-cost GNSS devices were able to provide horizontal accuracy lower than 10 mm in urban areas in 85% of sessions, while the vertical and spatial accuracy was lower than 15 mm in 82.5% and 77.5% of the sessions, respectively. In the open sky, low-cost GNSS receivers achieve a horizontal, vertical, and spatial accuracy of 5 mm for all sessions considered. In RTK mode, positioning accuracy varies between 10–30 mm in the open-sky and urban areas, while better performance is demonstrated for the former.

20 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VHVeton Hamza
Veton Hamza
BSBojan Stopar
Bojan Stopar
TATomaž Ambrožič
Tomaž Ambrožič
OSOskar Sterle
Oskar Sterle
Low-cost Global Navigation Satellite System (GNSS) receivers are currently used in various engineering applications. These low-cost devices are regarded as suitable sensors for applications in areas with a high risk of instrument damage. The main objectives of this research were to identify the size of displacements that can be detected in relative and absolute positioning modes by low-cost GNSS instruments and to compare the results of selected antennas. Additionally, geodetic and low-cost GNSS instruments were compared in the level of observations. For this study, low-cost SimpleRTK2B V1 boards, which house ZED-F9P GNSS chips, and three low-cost antennas, namely, Survey, Tallysman TW3882, and Survey Calibrated, were selected. While antenna calibration parameters are known for the last antenna, this is not the case for the first two. For testing purposes, a geodetic network consisting of four points was established; horizontal and vertical movements were imposed by a special mechanism with high accuracy. In relative positioning mode, the results indicate that the Survey Calibrated antenna can detect horizontal and vertical displacements with sizes of 4 mm, and 6 mm, respectively. In the detection of horizontal displacements, the performance of the Survey antenna was not as good as that of Tallysman, and the sizes of detected displacements were 6 mm and 4 mm for the first, and second antennas, respectively. Vertical displacements of 9 mm were detected using both Survey and Tallysman antennas. In absolute positioning mode, Survey Calibrated also had better performance than the Tallysman antenna, and spatial displacements of 20 mm or greater were detected by low-cost GNSS instruments. The observations made with low-cost and geodetic GNSS instruments were compared, and the latter showed better performance. However, the differences in cycle slips and the noise of phase observations were inferior. Considering their cost and proven performance, it can be concluded that such sensors can be considered for setting up a highly accurate but low-cost geodetic monitoring system.