MEMS resonators have become core devices in a large number of fields; however, due to their complex structures, the finite element analysis (FEA) method is still the main method for their theoretical analysis. The traditional finite element analysis method faces the disadvantages of large calculation amount and long simulation time, which limits the development of high-performance MEMS resonators. This paper demonstrates a high-speed and high-accuracy simulation tool based on the artificial neural network, where a multilayer perceptron (MLP) neural network model is constructed. The typical structural parameters of MEMS resonator are used as the input layer, and its performance indicators produced by the finite element analysis method are the output layer. After iteratively trained with 4000 samples, the cumulative error of the neural network decreases to 0.0017 and a prediction network model is obtained. Compared with the finite element analysis results, the structural accuracy error predicted by the neural network model can be controlled within 6%, but its runtime is shortened by 15,000 times. This high-speed and high-accuracy mathematical modeling method can effectively improve the analyzing efficiency and provide a promising tool for the design and optimization of different complex MEMS resonators, which exhibit remarkable accuracy and speed.
MEMS gyroscopes play an important role in inertial navigation measurements, which mainly works in n = 2 mode. However, mode matching is the basis for high-precision detection, which can improve the sensitivity, resolution, and signal-to-noise ratio of the gyroscopes. An initial frequency split is inevitably generated during the manufacturing process. There are two methods to eliminate the frequency split and to achieve mode matching for the gyroscopes, which are electrostatic tuning and mechanical trimming, respectively. In this paper, we report a novel ring MEMS resonator and a novel method of mechanical frequency tuning. The most prominent characteristic of the resonator is that 16 raised mass blocks are increased in the circumferential positions of the ring uniformly. This structural design can achieve mass-stiffness decoupling, which means that punching holes on the mass blocks only affects the mass distribution but the stiffness is almost unchanged for the resonator. We verify the mass-stiffness decoupling by way of comparing the simulation with the conventional resonator. In addition, we put up an online tuning platform based on a femtosecond laser and reduce a resonator’s frequency split from 23.3 Hz to 0.4 Hz, which reveals that the frequency split is linearly related to the removed mass. These findings will have a referential significance for other transducers.
Capacitive micromechanical resonators share electrodes with the same bias voltage, resulting in the occurrence of electrostatic coupling between intrinsic modes. Unlike the traditional mechanical coupling, the electrostatic coupling is determined by the structural electric potential energy, and generally, it only occurs when the coupling modes operate in nonlinear regions. However, previous electrostatic coupling studies mainly focus on the stiffness softening region, with little attention on the opposite stiffness hardening condition. This paper presents a study on the electrostatic modal coupling effect in the stiffness hardening region. A novel capacitive micromechanical resonator with different modal nonlinearities is designed and fabricated. It is demonstrated that activating a cavity mode can shift the fundamental resonance of the manipulated mode by nearly 90 times its mechanical bandwidth. Moreover, the frequency shifting direction is found to be related to the manipulated mode’s nonlinearity, while the frequency hopscotch is determined by the cavity mode’s nonlinearity. The electrostatic coupling has been proven to be an efficient and tunable dynamical coupling with great potential for tuning the frequency in a wide range. The modal coupling theory displayed in this paper is suitable for most capacitive resonators and can be used to improve the resonator’s performance.
For micro-electromechanical system (MEMS) resonators, once the devices are fabricated and packaged, their intrinsic quality factors (Q) will be fixed and cannot be changed, which seriously limits the further improvement of the resonator’s performance. In this paper, parametric excitation is applied in a push-pull driven disk resonator gyroscope (DRG) to improve its sensitivity by an electrical pump, causing an arbitrary increase of the “effective Q”. However, due to the differential characteristics of the push-pull driving method, the traditional parametric excitation method is not applicable. As a result, two novel methods are proposed and experimentally carried out to achieve parametric excitation in the push-pull driven DRGs, resulting in a maximum “effective Q” of 2.24 × 106 in the experiment, about a 7.6 times improvement over the intrinsic Q. Besides, subharmonic excitation is also theoretically analyzed and experimentally characterized. The stability boundary of parametric excitation, defined by a threshold voltage, is theoretically predicted and verified by related experiments. It is demonstrated that, when keeping the gyroscope’s vibration at a constant amplitude, the fundamental frequency driving voltage will decrease with the increasing of the parametric voltage and will drop to zero at its threshold value. In this case, the gyroscope operates in a generalized parametric resonance condition, which is called subharmonic excitation. The novel parametric and subharmonic excitation theories displayed in this paper are proven to be efficient and tunable dynamical methods with great potential for adjusting the quality factor flexibly, which can be used to further enhance the resonator’s performance.
1 January 2020 in Journal of Mechanical Engineering