Modern structures of electrical power systems are expected to have more domination of renewable energy sources. However, renewable energy-based generation systems suffer from their lack of or reduced rotating masses, which is the main source of power system inertia. Therefore, the frequency of modern power systems represents an important indicator of their proper and safe operation. In addition, the uncertainties and randomness of the renewable energy sources and the load variations can result in frequency undulation problems. In this context, this paper presents an improved cascaded fractional order-based frequency regulation controller for a two-area interconnected power system. The proposed controller uses the cascade structure of the tilt integral derivative (TID) with the fractional order proportional integral derivative with a filter (FOPIDN or PIDN) controller (namely the cascaded TID-FOPIDN or TID-PIDN controller). Moreover, an optimized TID control method is presented for the electric vehicles (EVs) to maximize their benefits and contribution to the frequency regulation of power systems. The recent widely employed marine predators optimization algorithm (MPA) is utilized to design the new proposed controllers. The proposed controller and design method are tested and validated at various load and renewable source variations, as is their robustness against parameter uncertainties of power systems. Performance comparisons of the proposed controller with featured frequency regulation controllers in the literature are provided to verify the superiority of the new proposed controller. The obtained results confirm the stable operation and the frequency regulation performance of the new proposed controller with optimized controller parameters and without the need for complex design methods.
The integration of photovoltaic (PV) systems with three-phase four-wire (3P4W) distribution networks has imposed several challenges related to existing unbalanced loads, reactive power generation and harmonics content. In this paper, a multifunctional distributed maximum power point (MPPT) controller for grid integration of PV systems is proposed. The proposed distributed MPPT controller is developed based on employing a four-leg three-level T-type multilevel inverter. The proposed inverter performs multifunctionalities, including distributed MPPT, neutral current compensation for the unbalanced loads, supplying reactive power into the grid and the grid integration. Moreover, the proposed inverter overcomes the stochastic behavior of both the PV generation with partial shading problems and its operation with unbalanced loads as well. Furthermore, the new proposed controller injects sinusoidal output currents with decreased levels of total harmonic distortion (THD) into the grid. The tested case study is investigated for the various operating scenarios of PV generation and load demands. The results and tabulated performance comparisons have proven the superior performance of the proposed multifunctional PV generation system. The results show the ability of the proposed controller to efficiently extract distributed MPPT for all PV modules at all the tested scenarios. Additional improvement of the energy efficiency is achieved through the elimination of the neutral current due to existing unbalanced loads.
A reduced power system’s inertia represents a big issue for high penetration levels of renewable generation sources. Recently, load frequency controllers (LFCs) and their design have become crucial factors for stability and supply reliability. Thence, a new optimized multiloop fractional LFC scheme is provided in this paper. The proposed multiloop LFC scheme presents a two-degree-of-freedom (2DOF) structure using the tilt–integral–derivatives with filter (TIDN) in the first stage and the tilt–derivative with filter (TDN) in the second stage. The employment of two different loops achieves better disturbance rejection capability using the proposed 2DOF TIDN-TDN controller. The proposed 2DOF TIDN-TDN method is optimally designed using the recent powerful marine predator optimizer algorithm (MPA). The proposed design method eliminates the need for precise modeling of power systems, complex control design theories, and complex disturbance observers and filter circuits. A multisourced two-area interlinked power grid is employed as a case study in this paper by incorporating renewable generation with multifunctionality electric vehicle (EV) control and contribution within the vehicle-to-grid (V2G) concept. The proposed 2DOF TIDN-TDN LFC is compared with feature-related LFCs from the literature, such as TID, FOTID, and TID-FOPIDN controllers. Better mitigated frequency and tie-line power fluctuations, faster response, lower overshot/undershot values, and shorter settling time are the proven features of the proposed 2DOF TIDN-TDN LFC method.
1 December 2024 in Aswan University Journal of Sciences and Technology
Due to climate change, shifting from conventional generation sources to new renewable energy production has become important. Power systems are becoming more susceptible to issues with low inertia due to increased reliance rates on renewable energy sources (RESs). Fractional order has recently attracted a lot of interest and investigation. As a result, dynamic systems and controllers with fractional order (FO) are becoming more popular. The responsiveness and stability of the load frequency control (LFC) system are enhanced in this article using FO controllers. The performance of the proposed fractional order proportional-integral-derivative (FOPID) controller is compared against the conventional proportional-integral-derivative (PID) controller. The optimal gain values of the two controllers will be optimized utilizing the marine predator optimization algorithm (MPA), and a performance comparison was carried out with several objective functions. After comparing the settling times, overshoot, undershoot, oscillation of frequency deviation, and tie-line power of the single and dual-area hybrid power systems (SAHPS & DAHPS), it is possible to conclude that, in the occurrence of load disturbance changes and the widespread use of RESs, the suggested FOPID controller performs more effectively and is more robust than the conventional controller. It minimized the ISE after 32 iterations with 83.73%, IAE with 75%, ITSE with 93.77%, and ITAE with 83.58% compared to the PID controller at load variation.