Marko Tapani

Dr. Marko Tapani

Centre for Wireless Communications, University of Oulu, Oulu, Finland
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2023 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Open access
ZSZeeshan Siddiqui
Zeeshan Siddiqui
Marko TapaniMarko Tapani
Marko Tapani
KRKimmo Rasilainen
Kimmo Rasilainen
JCJiangcheng Chen
Jiangcheng Chen
MBMarkus Berg
Markus Berg
APAarno Pärssinen
Aarno Pärssinen
This paper presents a dual-band, dual-polarized antenna operating from 24GHz up to 40 GHz at 5G New Radio (NR) millimeter-wave Frequency Range 2 (FR2) bands. A novel stacking arrangement of ring patches is proposed to achieve wide dual-band operation with stable gain. Two pairs of stacked ring patches operating at lower (24.25 to 29.5 GHz) and upper (37 to 40 GHz) FR2 bands are alternately integrated at four metal layers. The antenna offers a sharp roll-off and a filter-like response with radiation nulls between the operating bands due to the stacking configuration. The antenna is aperture-coupled and stripline-fed, and it conforms to the Antenna-in-Package (AiP) requirements. The proposed single antenna element and a 2×2 array are fabricated utilizing a standard commercial PCB fabrication facility. The measurement results show a decent agreement with the simulations in terms of impedance matching, isolation, radiation patterns, and realized gain. The proposed design is a promising candidate for 5G millimeter-wave base station antenna arrays.

6 September 2021 in Telecom
Verified
Journal Article
Open access
PDF file
Mariella SärestöniemiMariella Särestöniemi
Mariella Särestöniemi
Marko TapaniMarko Tapani
Marko Tapani
sami myllymäkisami myllymäki
sami myllymäki
CPCarlos Pomalaza-Raez
Carlos Pomalaza-Raez
This paper describes the development and evaluation of an on-body flexible antenna designed for an in-body application, as well as on-body communications at ISM and UWB frequency bands. The evaluation is performed via electromagnetic simulations using the Dassault Simulia CST Studio Suite. A planar tissue layer model, as well as a human voxel model from the human abdominal area, are used to study the antenna characteristics next to human tissues. Power flow analysis is presented to understand the power flow on the body surface as well as within the tissues. Simulation results show that this wearable flexible antenna is suitable for in-body communications in the intestinal area, e.g., for capsule endoscopy, in the industrial, scientific, and medical (ISM) band and at lower ultra-wideband (UWB). At higher frequencies, the antenna is suitable for on-body communications as well as in-body communications with lower propagation depth requirements. Additionally, an antenna prototype has been prepared and the antenna performance is verified with several on-body measurements. The measurement results show a good match with the simulation results. The novelty of the proposed antenna is a compact size and the flexible substrate material, which makes it feasible and practical for several different medical diagnosis and monitoring applications.

15 February 2018 in ETRI Journal
Verified
Journal Article
Closed access
PDF file
MLMarko E. Leinonen
Marko E. Leinonen
GDGiuseppe Destino
Giuseppe Destino
OKOlli Kursu
Olli Kursu
Marko TapaniMarko Tapani
Marko Tapani
APAarno Pärssinen
Aarno Pärssinen

28 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JJJanne Janhunen
Janne Janhunen
Konstantin MikhaylovKonstantin Mikhaylov
Konstantin Mikhaylov
JPJuha Petäjäjärvi
Juha Petäjäjärvi
Marko TapaniMarko Tapani
Marko Tapani
The number of IoT (Internet of Things) devices is predicted to increase dramatically in the years to come and their manufacturing and maintenance, including both commercial and ecological aspects associated with these, are gaining substantial attention. One of the effective ways of addressing both these issues at a time is the energy-neutral systems, which operate with the energy harvested from their environment. To address the major problem of this system, namely the low reliability, in the current paper, we develop and study the utility of a system powered solely with the wireless power transfer (WPT) over a radio frequency (RF) channel. In the article, we propose a methodology for developing and implementing a real-life IoT application based on RF WPT. We employ the proposed methodology to develop a WPT-powered solution to sense the temperature and the angular velocity in the rotating industrial environment. First, we discuss the key trade-offs arising when selecting and developing the new components for a WPT system. Then, we present and detail our solutions and describe the results of their evaluations. Finally, we instrument and evaluate the complete system, proving that it is capable of meeting all the design goals and requirements. The results reported in this paper can be of interest to the practitioners, for whom they provide a step-by-step methodology of WPT application development with a practical example. In addition, these results may be valuable for analysts, as they demonstrate many practical interrelations and effects specific to the real-life WPT applications.

1 November 2020 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
ZSZeeshan Siddiqui
Zeeshan Siddiqui
Marko TapaniMarko Tapani
Marko Tapani
MTMarko Tuhkala
Marko Tuhkala
sami myllymäkisami myllymäki
sami myllymäki
A novel technique to periodically modulate the aperture of a coupled mode leaky coaxial cable (LCX) is presented in this communication. The surface wave (monofilar mode) over the cable is modulated by periodically slotted aperture, converting it to a leaky wave. This leaky wave due to periodic modulation complements the leaked bifilar mode, thus enhancing the radiation efficiency of the LCX. The numerical results obtained through CST simulation are presented to prove the co-existence of a complex surface wave and a leaky wave over the surface of periodically modulated cable. As a proof of concept, a periodically slotted LCX operating at 4.5 GHz is designed and fabricated. Parametric studies are performed to observe the influence of the key parameters on the radiation performance. The measured results reasonably agree with the simulations.

30 September 2019 in International Journal of Wireless Information Networks
Verified
Journal Article
Open access
PDF file
CKChaïmaâ Kissi
Chaïmaâ Kissi
Mariella SärestöniemiMariella Särestöniemi
Mariella Särestöniemi
TKTimo Kumpuniemi
Timo Kumpuniemi
Marko TapaniMarko Tapani
Marko Tapani
sami myllymäkisami myllymäki
sami myllymäki
CPCarlos Pomalaza-Raez
Carlos Pomalaza-Raez
The paper presents a novel antenna operating at the lower UWB band (3.75–4.25 GHz), defined originally in IEEE 802.15.6 standard for Body Area Networks (BAN) applications. The proposed antenna is designed for biomedical application, wireless capsule endoscopy localization. In other words, the concerned application is dedicated to track a capsule, by means of an external device, swallowed by the patient to provide captured images of the Small Intestine (SI), essential part of the GastroIntestinal (GI) tract, and transfer them in real-time to the external device. In this context, antenna with and without cavity-backed structures, are presented and compared with the requirements for a receiving antenna in terms of directivity and bandwidth coverage in question. It was revealed that the cavity approach improved the antenna gain up to 8 dBi, at the 4 GHz center frequency, compared to 6 dBi without the cavity presence. Simulations were carried out using CST Microwave Studio, and the results were validated by measurements in proximity to human body. The antenna safety issue was assessed with CST SAR (Specific Absorption Rate) calculation, in compliance with IEEE/IEC 62704-1 standard. Results showed a maximum SAR of 0.112 W/kg and 0.005 W/kg at 4 mm and 30 mm antenna-skin distance, in the range of the SAR limit guidelines defined by safety standards. The cavity-backed antenna ability to penetrate the human tissues, to reach the small intestine layer was studied by means of CST voxel model and compared to a multi-layer model emulating the dielectric properties of the human tissues at 4 GHz. This analysis was conducted using power flow results and completed by the power field probes at the several tissue interfaces.