The eicosanoid metabolic pathway is responsible for mediating the production of various inflammatory factors that are closely related to the development and resolution of inflammation. In biological matrices, the major quantifying obstacles were shown to be the oxidation and low quantities of eicosanoids and their metabolites. This study aimed to develop a reliable, sensitive ultrahigh-performance liquid chromatography coupled to a tandem mass spectrometry (UPLC–MS/MS) method to quantify eicosanoids in human serum. Solid-phase extraction (SPE) was used for sample preparation. The approach employed continuous ionization polarity switching. The target eicosanoids showed good linearity over the investigated concentration range (r2 > 0.99). The recovery rates were over 64.5%, and the matrix effects ranged from 73.0 to 128.0%. The limits of quantification were 0.048 ~ 0.44 ng/mL. For the broad concentration range, the CV % for accuracy and precision were less than ± 20%. We successfully applied this method to rapidly analyse 74 serum samples from severe influenza pneumonia, severe bacterial pneumonia and healthy individuals. Eicosanoid-related metabolite concentrations were quantified within a range similar to those of previously published articles. Compared to healthy individuals, our application found that 20-HETE, 14,15-EET and 11,12-EET were upregulated in severe influenza pneumonia patients, while LTB4 was downregulated. 8-HETE and 5-HETE were upregulated in severe bacterial pneumonia patients, while LTE4 was downregulated. This approach provides a means for monitoring the low quantities of eicosanoids in biological matrices, and our finding that different characteristic metabolite profiles may help discriminate the induction of severe pneumonia patients.
For patients who treated with tacrolimus after kidney transplant, therapeutic drug monitoring is essential to improve their prognosis. However, previous detection methods have limitations, such as the overestimation and unacceptable bias in the immunoassays. Precision medicine has been challenged. The liquid chromatography-tandem mass spectrometry (LC-MS/MS) method is recognized as the gold standard due to its accuracy and specificity, but lack of throughput and complex process limits its clinical application. Therefore, an accurate, simple and high throughput method for tacrolimus monitoring is needed for clinical practice. A modified LC-MS/MS method was introduced and validated. Whole blood samples were prepared by a one-step protein precipitation method. Chromatographic separation was achieved using a Phenomenex Kinetex 2.6 μm XB-C18 2.1 × 50 mm column with a total run time of 3.5 min to avoid matrix effect. An electrospray ionization source (ESI) was used in positive ion multiple reaction monitoring (MRM) mode for mass spectrometric detection. In order to protect the mass spectrometer, only part of the sample after LC separation was allowed to enter the mass spectrum, through a two HPLC systems coupled one mass spectrometry design. In this way, the instrument throughput is also improved and realizing the detection of 2 samples within 3.5 min and carried out a shorter analyzing time for each sample of 1.75 min. Additionally, we calculated tacrolimus-intrapatient variant (Tac-IPV) based on this modified method and assessed the prognostic value of Tac-IPV in Chinese kidney transplant patients. The LC-MS/MS was modified by streamlining the procedure and increasing the throughput. The method proved to be accurate and reproducible with all performance parameters suitably meeting the clinical requirements over a calibration ranged from 0.37 to 42.90 ng/mL. Parameters such as linearity, limit of quantification (LoQ) and dilution integrity were validated with a clinical reportable range from 0.37 to 343.20 ng/mL, which was particularly useful for high drug concentrations patients (rare but very serious). Both cross-contamination and matrix effects were negligible. Clinical data of 83 patients showed that Tac-IPV was associated with poor kidney transplant outcome in Chinese (Hazard Ratio (HR) = 3.96, 4.75; 95% Cl: 1.10–14.21, 1.23–18.36; P < 0.05). This modified LC-MS/MS method possessed high throughput and simple sample preparation, allowing it to meet daily clinical needs. At the same time, Tac-IPV based on this modified LC-MS/MS had excellent prognostic value in kidney transplantation. These advantages have great significance for the individualized treatment of Chinese kidney transplant patients and broad application of Tac-IPV.
2 July 2022 in Journal of Clinical Laboratory Analysis
Background: Eighteen‐hydroxycortisol (18‐OHF) is a potential biomarker for differential diagnosis of the two major primary aldosteronism subtypes, aldosterone‐producing adenoma, and idiopathic hyperaldosteronism.Methods: Urine samples were processed, and the 18‐OHF in urine samples were successfully quantified by in‐house established dilute‐and‐shoot liquid chromatography–tandem mass spectrometry (LC–MS/MS) method. Separation was accomplished on a Sigma Ascentis Express C18 column with a gradient mixture of phase (A) 0.2% formic acid in water and phase (B) 0.2% formic acid in methanol at a flow rate of 0.4 ml/min. Mass spectrometric detection was performed in positive electrospray ionization mode via a mass spectrometer.Results: The linearity of urinary 18‐OHF ranged from 4.28 to 8.77 × 103 nmol/L, with a lower limit of quantification at 4.28 nmol/L. The intra‐ and inter‐precision were both below 3%. The range of analytical recovery was 97.8%–109.2%. The validated dilute‐and‐shoot LC–MS/MS method was compared with the SPE LC–MS/MS method modified from the one reported in 2013. The results by Passing–Bablok regression analysis and Bland–Altman plotting demonstrated a good agreement between the two methods. The presented method was then applied to establish sex‐specific reference intervals from 62 males and 62 females, respectively. The calculated 2.5%–97.5% reference intervals for 24‐h urinary 18‐OHF were 113–703 nmol/day for males and 71.2–450 nmol/day for females.Conclusion: The presented dilute‐and‐shoot LC–MS/MS method for 18‐OHF quantification showed a good performance in the clinical application. Furthermore, the sex‐specific reference intervals for 24‐h urinary 18‐OHF were first established and quite important for its application in primary aldosteronism subtyping.
23 May 2023 in Experimental and Therapeutic Medicine
With time, the number of samples in clinical laboratories from therapeutic drug monitoring has increased. Existing analytical methods for blood cyclosporin A (CSA) monitoring, such as high‑performance liquid chromatography (HPLC) and immunoassays, have limitations including cross‑reactivity, time consumption, and the complicated procedures involved. Liquid chromatography‑tandem mass spectrometry (LC‑MS/MS) has long been considered the reference standard owing to its high accuracy, specificity, and sensitivity. However, large numbers of blood samples, multi‑step preparation procedures, and longer analytical times (2.5‑20 min) are required as a consequence of the different technical strategies, to ensure good analytical performance and routine quality assurance. A stable, reliable, and high throughput detection method will save personnel time and reduce laboratory costs. Therefore, a high throughput and simple LC‑MS/MS method was developed and validated for the detection of whole‑blood CSA with CSA‑d12 as the internal standard in the present study. Whole blood samples were prepared through a modified one‑step protein precipitation method. A C18 column (50x2.1 mm, 2.7 µm) with a mobile phase flow rate of 0.5 ml/min was used for chromatographic separation with a total running time of 4.3 min to avoid the matrix effect. To protect the mass spectrometer, only part of the sample after LC separation was allowed to enter the mass spectrum, using two HPLC systems coupled to one mass spectrometry. In this way, throughput was improved with detection of two samples possible within 4.3 min using a shorter analytical time for each sample of 2.15 min. This modified LC‑MS/MS method showed excellent analytical performance and demonstrated less matrix effect and a wide linear range. The design of multi‑LC systems coupled with one mass spectrometry may play a notable role in the improvement of daily detection throughput, speeding up LC‑MS/MS, and allowing it to be an integral part of continuous diagnostics in the near future.
Backgrounds: Systemic amyloidosis is classified according to the deposited amyloid fibril protein (AFP), which determines its best therapeutic scheme. The most common type of AFP found are immunoglobulin light chains. The laser microdissection combined with mass spectrometry (LMD-MS) technique is a promising approach for precise typing of amyloidosis, however, the major difficulty in interpreting the MS data is how to accurately identify the precipitated AFP from background. Objectives: The objective of the present study is to establish a complete data interpretation procedure for LMD-MS based amyloidosis typing. Methods: Formalin-fixed paraffin-embedded specimens from patients with renal amyloidosis and non-amyloid nephropathies (including diabetic nephropathy, fibrillary glomerulonephritis, IgA nephropathy, lupus nephritis, membranous nephropathy, and normal tissue adjacent to tumors) were analyzed by LMD-MS. Forty-two specimens were used to train the data interpretation procedure, which was validated by another 50 validation specimens. Area under receiver operating curve (AUROC) analysis of amyloid accompanying proteins (AAPs, including apolipoprotein A-IV, apolipoprotein E and serum amyloid P-component) for discriminating amyloidosis from non-amyloid nephropathies was performed. Results: A stepwise data interpretation procedure that includes or excludes the types of amyloidosis group by group was established. The involvement of AFPs other than immunoglobulin was determined by P-score, as well as immunoglobulin light chain by variable of λ-κ, and immunoglobulin heavy chain by H-score. This achieved a total of 88% accuracy in 50 validation specimens. The AAPs showed significantly different expression levels between amyloidosis specimens and non-amyloid nephropathies. Each of the single AAP had a AUROC value more than 0.9 for diagnosis of amyloidosis from non-amyloid control, and the averaged level of the three AAPs showed the highest AUROC (0.966), which might be an alternative indicator for amyloidosis diagnosis. Conclusions: The proteomic data interpretation procedure for LMD-MS based amyloidosis typing was established successfully that has a high practicability in clinical application.