With the aging of the social population structure, the number of empty-nesters is also increasing. Therefore, it is necessary to manage empty-nesters with data mining technology. This paper proposed an empty-nest power user identification and power consumption management method based on data mining. Firstly, an empty-nest user identification algorithm based on weighted random forest was proposed. Compared with similar algorithms, the results indicate that the performance of the algorithm is the best, and the identification accuracy of empty-nest users is 74.2%. Then a method for analyzing the electricity consumption behavior of empty-nest users based on fusion clustering index adaptive cosine K-means was proposed, which can adaptively select the optimal number of clusters. Compared with similar algorithms, the algorithm has the shortest running time, the smallest Sum of the Squared Error (SSE), and the largest mean distance between clusters (MDC), which are 3.4281 s, 31.6591 and 13.9513, respectively. Finally, an anomaly detection model with an Auto-regressive Integrated Moving Average (ARIMA) algorithm and an isolated forest algorithm was established. The case analysis shows that the recognition accuracy of abnormal electricity consumption for empty-nest users was 86%. The results indicate that the model can effectively detect the abnormal behavior of empty-nest power users and help the power department to better serve empty-nest users.
In this paper, a new calibration device for an air flow sensor of the VAV terminal unit is designed. Multi-aperture air outlets are designed to meet the calibration requirements of the air flow sensor in a variety of measurement range. The device can calibrate the air flow sensors of different types of VAV terminal unit by a movable flow rectifier without repeating the design of a different calibration pipeline. The Raspberry PI is used to design the high-performance GUI interface and controlling algorithm to achieve a one-button intelligent calibration. The air flow sensors in three different types of VAV terminal units are used to calibrate the experiment. After testing, the differential pressure value measured by the air flow sensor can accurately measure the air flow within the accuracy of 5% after the formula conversion. The conversion from differential pressure values to air flow values requires precise calibration in order to establish an accurate air flow equation, and here the calibration device plays a key role. The negative effect caused by the distance between the flow rectifiers and the VAV terminal unit is discovered. In other words, the distance between the inlet flow rectifier and the air inlet of VAV terminal unit should be kept as close as possible, or within a range of 2~3 cm. Moreover, the distance between the air outlet of VAV terminal unit and the middle-flow rectifier should be kept as close as possible; otherwise, any slight gap will cause a huge error in the calibration result. The research contributes to the further study of airflow sensing technology through the conversion and calibration of differential pressure measurements to accurate air flow values.
One time radial vibration, mostly caused by rotary eccentric load, may reduce the reliability and operating life of motors. In order to mitigate the one time radial vibration in permanent magnet motors, a real time detection method for rotary eccentric load based on the theoretical analysis of the motor vibration and the mechanical analysis was given, and a novel control strategy based on FOC (field oriented control) was proposed, which could produce the artificial pulsating torque to suppress the impact of vibration cause by the eccentric load. The control algorithm was investigated and tested on a real time permanent magnet motor drive system platform. The experimental results indicate that the proposed methods are simple and easy to be applied in the digital control system and the control strategy is practical.