Shah Mukim Uddin

Mr. Shah Mukim Uddin

Department of Medicine, The University of Melbourne, Royal Melbourne Hospital, Victoria 3050, Australia
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
ASAbkar Sayad
Abkar Sayad
FIFatimah Ibrahim
Fatimah Ibrahim
SUShah Mukim Uddin
Shah Mukim Uddin
JCJongman Cho
Jongman Cho
Marc MadouMarc Madou
Marc Madou
KTKwai Lin Thong
Kwai Lin Thong

1 May 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ASAbkar Ahmed Sayad
Abkar Ahmed Sayad
FIFatimah Ibrahim
Fatimah Ibrahim
SUShah Mukim Uddin
Shah Mukim Uddin
KPKoh Xiu Pei
Koh Xiu Pei
MMMas S. Mohktar
Mas S. Mohktar
KTKwai Lin Thong
Kwai Lin Thong

9 November 2015 in Scientific Reports
Verified
Journal Article
Open access
SHSamira Hosseini
Samira Hosseini
MAMohammad M. Aeinehvand
Mohammad M. Aeinehvand
SUShah Mukim Uddin
Shah Mukim Uddin
ABAbderazak Benzina
Abderazak Benzina
HRHussin A. Rothan
Hussin A. Rothan
FIFatimah Ibrahim
Fatimah Ibrahim
The application of microfluidic devices in diagnostic systems is well-established in contemporary research. Large specific surface area of microspheres, on the other hand, has secured an important position for their use in bioanalytical assays. Herein, we report a combination of microspheres and microfluidic disk in a unique hybrid platform for highly sensitive and selective detection of dengue virus. Surface engineered polymethacrylate microspheres with carefully designed functional groups facilitate biorecognition in a multitude manner. In order to maximize the utility of the microspheres’ specific surface area in biomolecular interaction, the microfluidic disk was equipped with a micromixing system. The mixing mechanism (microballoon mixing) enhances the number of molecular encounters between spheres and target analyte by accessing the entire sample volume more effectively, which subsequently results in signal amplification. Significant reduction of incubation time along with considerable lower detection limits were the prime motivations for the integration of microspheres inside the microfluidic disk. Lengthy incubations of routine analytical assays were reduced from 2 hours to 5 minutes while developed system successfully detected a few units of dengue virus. Obtained results make this hybrid microsphere-microfluidic approach to dengue detection a promising avenue for early detection of this fatal illness.

20 May 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
ASAbkar Sayad
Abkar Sayad
SUShah Mukim Uddin
Shah Mukim Uddin
SYScarlett Yao
Scarlett Yao
HWHarold Wilson
Harold Wilson
JCJianxiong Chan
Jianxiong Chan
Patrick KwanPatrick Kwan
Patrick Kwan

5 March 2015 in Sensors
Verified
Journal Article
Open access
PDF file
SUShah Mukim Uddin
Shah Mukim Uddin
FIFatimah Ibrahim
Fatimah Ibrahim
ASAbkar Ahmed Sayad
Abkar Ahmed Sayad
ATAung Thiha
Aung Thiha
KPKoh Xiu Pei
Koh Xiu Pei
KTKwai Lin Thong
Kwai Lin Thong
In recent years, many improvements have been made in foodborne pathogen detection methods to reduce the impact of food contamination. Several rapid methods have been developed with biosensor devices to improve the way of performing pathogen detection. This paper presents an automated endpoint detection system for amplicons generated by loop mediated isothermal amplification (LAMP) on a microfluidic compact disk platform. The developed detection system utilizes a monochromatic ultraviolet (UV) emitter for excitation of fluorescent labeled LAMP amplicons and a color sensor to detect the emitted florescence from target. Then it processes the sensor output and displays the detection results on liquid crystal display (LCD). The sensitivity test has been performed with detection limit up to 2.5 × 10−3 ng/µL with different DNA concentrations of Salmonella bacteria. This system allows a rapid and automatic endpoint detection which could lead to the development of a point-of-care diagnosis device for foodborne pathogens detection in a resource-limited environment.

25 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GSGita V. Soraya
Gita V. Soraya
CAChathurika D. Abeyrathne
Chathurika D. Abeyrathne
CBChristelle Buffet
Christelle Buffet
DHDuc H. Huynh
Duc H. Huynh
SUShah Mukim Uddin
Shah Mukim Uddin
SRStephen J Rogerson
Stephen J Rogerson
Malaria elimination is a global public health priority. To fulfil the demands of elimination diagnostics, we have developed an interdigitated electrode sensor platform targeting the Plasmodium falciparum Histidine Rich Protein 2 (PfHRP2) protein in saliva samples. A protocol for frequency-specific PfHRP2 detection in phosphate buffered saline was developed, yielding a sensitivity of 2.5 pg/mL based on change in impedance magnitude of the sensor. This protocol was adapted and optimized for use in saliva with a sensitivity of 25 pg/mL based on change in resistance. Further validation demonstrated detection in saliva spiked with PfHRP2 from clinical isolates in 8 of 11 samples. With a turnaround time of ~2 hours, the label-free platform based on impedance sensors has the potential for miniaturization into a point-of-care diagnostic device for malaria elimination.