David Fleming

Prof. David Fleming


Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Metallomics
Verified
Journal Article
Open access
PDF file
OPOlena Ponomarenko
Olena Ponomarenko
PPPaul F. La Porte
Paul F. La Porte
SSSatya P. Singh
Satya P. Singh
GLGeorge Langan
George Langan
DFDavid Fleming
David Fleming
IPIngrid J. Pickering
Ingrid J. Pickering
Organ and tissue-level studies demonstrate selenium binding to arsenic in vivo in mammals, facilitating excretion.

17 September 2007 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DFDavid Fleming
David Fleming
MGMihai Raul Gherase
Mihai Raul Gherase
Using a portable x-ray tube and silicon PiN diode detector, an improved approach to the measurement of arsenic in skin phantoms was demonstrated. Skin phantoms of 8 mm thickness were made from polyester resin, with arsenic concentrations ranging from 0 to 30 microg g(-1). The excitation of characteristic arsenic x-rays was performed with the x-ray tube and K(alpha) x-rays were used as an indicator of arsenic concentration. From repeated phantom measurements, an instrumental minimum detection limit of 0.446 +/- 0.006 microg g(-1) was found, using an acquisition time of 120 s (real time). This compares with previously reported approaches having instrumental minimum detection limits of 3.5 +/- 0.2 microg g(-1) (1800 s real time), 2.3 +/- 0.1 microg g(-1) (1000 s live time) and 0.40 +/- 0.06 microg g(-1) (1000 s live time).

1 October 2015 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
DFDavid Fleming
David Fleming
KFKelly A. Foran
Kelly A. Foran
JKJong Sung Kim
Jong Sung Kim
JGJudy R. Guernsey
Judy R. Guernsey

20 June 2013 in X-Ray Spectrometry
Verified
Journal Article
Closed access
PDF file
DFDavid Fleming
David Fleming
MGMihai R. Gherase
Mihai R. Gherase
MAMadeleine Anthonisen
Madeleine Anthonisen

1 January 2021 in Applied Radiation and Isotopes
Verified
Journal Article
Open access
DFDavid Fleming
David Fleming
SCSamantha L. Crook
Samantha L. Crook
CEColby T. Evans
Colby T. Evans
MNMichel N. Nader
Michel N. Nader
MAManuel Atia
Manuel Atia
AAAnil Adisesh
Anil Adisesh
Arsenic is a toxic metalloid which has been associated with a wide range of health effects in humans including skin abnormalities and an elevated risk of skin, bladder, kidney, and lung cancer, diabetes, and cardiovascular disease. The measurement of arsenic concentration in nail clippings is often used in population studies as an indicator of arsenic exposure. Portable X-ray fluorescence (XRF) is an emerging technique for measuring arsenic in nail clippings. In the current study, single toenail clippings from 60 Atlantic Canadian participants were assessed for arsenic using a new portable XRF approach. A mono-energetic portable XRF system using doubly curved crystal optics was used to measure each clipping for a total of 900 s. Energy spectra from each clipping were analyzed for arsenic characteristic X-rays to provide a normalized arsenic signal. The same clippings were then analyzed for arsenic concentration using a "gold standard" method of inductively coupled plasma mass spectrometry (ICP-MS). Nail clipping arsenic concentrations measured by ICP-MS ranged from 0.030 μg/g to 2.57 μg/g, with a median result of 0.14 μg/g. Portable XRF results for arsenic were compared against ICP-MS arsenic concentrations, with a linear equation of best fit determined between the two variables. A correlation coefficient of r = 0.77 was found from the 59 nail clippings returning an ICP-MS arsenic concentration above the limit of quantitation. When the comparison was limited to the 20 clippings having an XRF normalized signal at least twice as large as the associated uncertainty of measurement, the correlation coefficient was r = 0.89. With the selection of an arsenic concentration of 0.1 μg/g as a cut-off value between "exposed" and "non-exposed" individuals, the XRF method provided a test sensitivity of 76% and a specificity of 81%. The corresponding positive predictive value was 88% and the negative predictive value was 65%. The portable XRF technique used in this study shows promise as a means of assessing arsenic concentration in toenail clippings.

1 February 2017 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
DFDavid Fleming
David Fleming
MNMichel N. Nader
Michel N. Nader
KFKelly A. Foran
Kelly A. Foran
CGCraig Groskopf
Craig Groskopf
MRMichael C. Reno
Michael C. Reno
PPPatrick J. Parsons
Patrick J. Parsons