Katya Arquilla

Ms. Katya Arquilla

University of Colorado Boulder, USA
+1
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
KAKatya Arquilla
Katya Arquilla
AWAndrea K. Webb
Andrea K. Webb
AHAllison P Hayman
Allison P Hayman
Wearable health-monitoring systems should be comfortable, non-stigmatizing, and able to achieve high data quality. Smart textiles with electronic elements integrated directly into fabrics offer a way to embed sensors into clothing seamlessly to serve these purposes. In this work, we demonstrate the feasibility of electrocardiogram (ECG) monitoring with sewn textile electrodes instead of traditional gel electrodes in a 3-lead, chest-mounted configuration. The textile electrodes are sewn with silver-coated thread in an overlapping zig zag pattern into an inextensible fabric. Sensor validation included ECG monitoring and comfort surveys with human subjects, stretch testing, and wash cycling. The electrodes were tested with the BIOPAC MP160 ECG data acquisition module. Sensors were placed on 8 subjects (5 males and 3 females) with double-sided tape. To detect differences in R peak detectability between traditional and sewn sensors, effect size was set at 10% of a sample mean for heart rate (HR) and R-R interval. Paired student’s t-tests were run between adhesive and sewn electrode data for R-R interval and average HR, and a Wilcoxon signed-rank test was run for comfort. No statistically significant difference was found between the traditional and textile electrodes (R-R interval: t = 1.43, p > 0.1; HR: t = −0.70, p > 0.5; comfort: V = 15, p > 0.5).

13 September 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
KAKatya Arquilla
Katya Arquilla
LDLaura Devendorf
Laura Devendorf
AWAndrea K. Webb
Andrea K. Webb
AHAllison P Hayman
Allison P Hayman
Wearable physiological monitoring systems are becoming increasingly prevalent in the push toward autonomous health monitoring and offer new modalities for playful and purposeful interaction within human computer interaction (HCI). Sensing systems that can be integrated into garments and, therefore, daily activities offer promising pathways toward ubiquitous integration. The electrocardiogram (ECG) signal is commonly monitored in healthcare and is increasingly utilized as a method of determining emotional and psychological state; however, the complete ECG waveform with the P, Q, R, S, and T peaks is not commonly used, due to the challenges associated with collecting the full waveform with wearable systems. We present woven textile electrodes as an option for garment-integrated ECG monitoring systems that are capable of capturing the complete ECG waveform. In this work, we present the changes in the peak detection performance caused by different sizes, patterns, and thread types with data from 10 human participants. These testing results provide empirically-derived guidelines for future woven textile electrodes, present a path forward for assessing design decisions, and highlight the importance of testing novel wearable sensor systems with more than a single individual.

17 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KAKatya Arquilla
Katya Arquilla
AWAndrea K. Webb
Andrea K. Webb
AHAllison P Hayman
Allison P Hayman
The detection of psychological stress using the electrocardiogram (ECG) signal is most commonly based on the detection of the R peak—the most prominent part of the ECG waveform—and the heart rate variability (HRV) measurements derived from it. For stress detection algorithms focused on short-duration time windows, there is potential benefit in including HRV features derived from the detection of smaller peaks within the ECG waveform: the P, Q, S, and T waves. However, the potential drawback of using these small peaks is their smaller magnitude and subsequent susceptibility to noise, making them more difficult to reliably detect. In this work, we demonstrate the potential benefits of including smaller waves within binary stress classification using a pre-existing data set of ECG recordings from 57 participants (aged 18–40) with a self-reported fear of spiders during exposure to videos of spiders. We also present an analysis of the performance of an automated peak detection algorithm and the reliability of detection for each of the smaller parts of the ECG waveform. We compared two models, one with only R peak features and one with small peak features. They were similar in precision, recall, F1, area under ROC curve (AUC), and accuracy, with the greatest differences less than the standard deviations of each metric. There was a significant difference in the Akaike Information Criterion (AIC), which represented the information loss of the model. The inclusion of novel small peak features made the model 4.29×1028 times more probable to minimize the information loss, and the small peak features showed higher regression coefficients than the R peak features, indicating a stronger relationship with acute psychological stress. This difference and further analysis of the novel features suggest that small peak intervals could be indicative of independent processes within the heart, reflecting a psychophysiological response to stress that has not yet been leveraged in stress detection algorithms.

1 March 2018
Verified
Conference Paper
Closed access
YSYoung-Young Shen
Young-Young Shen
ABAbhishektha Boppana
Abhishektha Boppana
KAKatya Arquilla
Katya Arquilla
AHAllison P Hayman
Allison P Hayman
One major challenge in designing a spacesuit to safely accommodate its wearer is the inability to study interactions between the wearer and the suit. The current work presents requirements and a preliminary system design for a wearable sensor system capable of observing the dynamics and kinematics of human-spacesuit interaction, as well as characterizing wearer physiological responses and the suit environment during performance of suited tasks. The system will measure contact pressures, joint kinematics, temperature, humidity, and heart rate over most of the wearer's body, and accommodate anthropometries in the range between fifth percentile female to ninety-fifth percentile male in stature. Justifications for each requirement are presented, and applications of the system are discussed.

29 April 2022 in Acta Astronautica
Verified
Journal Article
Closed access
KAKatya Arquilla
Katya Arquilla
AWAndrea K Webb
Andrea K Webb
AAAllison P. Anderson
Allison P. Anderson

18 December 2023 in Acta Astronautica
Verified
Journal Article
Closed access
GNGolda Nguyen
Golda Nguyen
ASAleksandra Stankovic
Aleksandra Stankovic
RBRachel Bellisle
Rachel Bellisle
JTJessica Todd
Jessica Todd
RBRebecca Browder
Rebecca Browder
KAKatya Arquilla
Katya Arquilla