Tobias Broger

Mr. Tobias Broger

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2019 in Nature Microbiology
Verified
Journal Article
Closed access
PDF file
EMEmily L. MacLean
Emily L. MacLean
TBTobias Broger
Tobias Broger
SYSeda Yerlikaya
Seda Yerlikaya
BFB. Leticia Fernandez-Carballo
B. Leticia Fernandez-Carballo
MPMadhukar Pai
Madhukar Pai
CDClaudia Denkinger
Claudia Denkinger

31 December 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MBMichelle A. Bulterys
Michelle A. Bulterys
BWBradley Wagner
Bradley Wagner
MRMaël Redard-Jacot
Maël Redard-Jacot
ASAnita Suresh
Anita Suresh
NPNira Pollock
Nira Pollock
TBTobias Broger
Tobias Broger
Most diagnostic tests for tuberculosis (TB) rely on sputum samples, which are difficult to obtain and have low sensitivity in immunocompromised patients, patients with disseminated TB, and children, delaying treatment initiation. The World Health Organization (WHO) calls for the development of a rapid, biomarker-based, non-sputum test capable of detecting all forms of TB at the point-of-care to enable immediate treatment initiation. Lipoarabinomannan (LAM) is the only WHO-endorsed TB biomarker that can be detected in urine, an easily collected sample. This status update discusses the characteristics of LAM as a biomarker, describes the performance of first-generation urine LAM tests and reasons for slow uptake, and presents considerations for developing the next generation of more sensitive and impactful tests. Next-generation urine LAM tests have the potential to reach adult and pediatric patients regardless of HIV status or site of infection and facilitate global TB control. Implementation and scale-up of existing LAM tests and development of next-generation assays should be prioritized.

1 December 2018 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
PDF file
GSGeorge B. Sigal
George B. Sigal
APAbraham Pinter
Abraham Pinter
TLTodd L. Lowary
Todd L. Lowary
MKMasanori Kawasaki
Masanori Kawasaki
ALAndra Li
Andra Li
TBTobias Broger
Tobias Broger
The only currently commercialized point-of-care assay for tuberculosis (TB) that measures lipoarabinomannan (LAM) in urine (Alere LF-LAM) has insufficient sensitivity. We evaluated the potential of 100 novel monoclonal antibody pairs targeting a variety of LAM epitopes on a sensitive electrochemiluminescence platform to improve the diagnostic accuracy.

28 September 2020 in Journal of Clinical Investigation
Verified
Journal Article
Open access
PDF file
TBTobias Broger
Tobias Broger
MNMark P. Nicol
Mark P. Nicol
GSGeorge B. Sigal
George B. Sigal
Eduardo GotuzzoEduardo Gotuzzo
Eduardo Gotuzzo
AZAlexandra J. Zimmer
Alexandra J. Zimmer
CDClaudia Denkinger
Claudia Denkinger
BACKGROUND. Inadequate tuberculosis (TB) diagnostics are a major hurdle in the reduction of disease burden, and accurate point-of-care tests (POCTs) are urgently needed. We assessed the diagnostic accuracy of Fujifilm SILVAMP TB lipoarabinomannan (FujiLAM) POCT for TB diagnosis in HIV-negative outpatients and compared it with Alere Determine TB LAM Ag (AlereLAM) POCT and a laboratory-based ultrasensitive electrochemiluminescence LAM research assay (EclLAM). METHODS. In this multicenter diagnostic test accuracy study, we recruited HIV-negative adults with symptoms suggestive of pulmonary TB presenting to outpatient health care centers in Peru and South Africa. Urine samples were tested using FujiLAM, AlereLAM, and EclLAM, and the diagnostic accuracy was assessed against a microbiological reference standard (MRS) and a composite reference standard. RESULTS. Three hundred seventy-two HIV-negative participants were included and the prevalence of microbiologically confirmed TB was 30%. Compared with the MRS, the sensitivities of AlereLAM, FujiLAM, and EclLAM were 10.8% (95% confidence interval [CI] 6.3%–18.0%), 53.2% (95% CI 43.9%–62.1%), and 66.7% (95% CI 57.5%–74.7%), respectively. The specificities of AlereLAM, FujiLAM, and EclLAM were 92.3% (95% CI 88.5%–95.0%), 98.9% (95% CI 96.7%–99.6%), and 98.1% (95% CI 95.6%–99.2%), respectively. Positive likelihood ratios of AlereLAM, FujiLAM, and EclLAM were 1.4, 46.2, and 34.8, respectively, and positive predictive values were 37.5%, 95.2%, and 93.7%, respectively. CONCLUSION. Compared with AlereLAM, FujiLAM detected 5 times more patients with TB in HIV-negative participants, had a high positive predictive value, and has the potential to improve rapid diagnosis of TB at the point-of-care. EclLAM demonstrated that additional sensitivity gains are possible, which highlights LAM’s potential as a biomarker. Additional research is required to assess FujiLAM’s performance in prospective cohorts, its cost-effectiveness, and its impact in real-world clinical settings. FUNDING. Global Health Innovative Technology Fund, the UK Department for International Development, the Dutch Ministry of Foreign Affairs, the Bill and Melinda Gates Foundation, the Australian Department of Foreign Affairs and Trade, the German Federal Ministry of Education and Research through Kreditanstalt für Wiederaufbau, and the NIH and National Institute of Allergy and Infectious Diseases.

18 April 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TBTobias Broger
Tobias Broger
MTMichael Tsionksy
Michael Tsionksy
AMAnu Mathew
Anu Mathew
TLTodd L. Lowary
Todd L. Lowary
APAbraham Pinter
Abraham Pinter
GSGeorge B. Sigal
George B. Sigal
Tuberculosis (TB) infection was responsible for an estimated 1.3 million deaths in 2017. Better diagnostic tools are urgently needed. We sought to determine whether accurate TB antigen detection in blood or urine has the potential to meet the WHO target product profiles for detection of active TB. We developed Electrochemiluminescence (ECL) immunoassays for Lipoarabinomannan (LAM) and ESAT-6 detection with detection limits in the pg/ml range and used them to compare the concentrations of the two antigens in the urine and serum of 81 HIV-negative and -positive individuals with presumptive TB enrolled across diverse geographic sites. LAM and ESAT-6 overall sensitivities in urine were 93% and 65% respectively. LAM and ESAT-6 overall sensitivities in serum were 55% and 46% respectively. Overall specificity was ≥97% in all assays. Sensitivities were higher in HIV-positive compared to HIV-negative patients for both antigens and both sample types, with signals roughly 10-fold higher on average in urine than in serum. The two antigens showed similar concentration ranges within the same sample type and correlated. LAM and ESAT-6 can be detected in the urine and serum of TB patients, regardless of the HIV status and further gains in clinical sensitivity may be achievable through assay and reagent optimization. Accuracy in urine was higher with current methods and has the potential to meet the WHO accuracy target if the findings can be transferred to a point-of-care TB test.

1 May 2020 in PLOS Medicine
Verified
Journal Article
Open access
PDF file
TBTobias Broger
Tobias Broger
MNMark P. Nicol
Mark P. Nicol
RSRita Székely
Rita Székely
SBStephanie Bjerrum
Stephanie Bjerrum
BSBianca Sossen
Bianca Sossen
SSSamuel G. Schumacher
Samuel G. Schumacher
Tuberculosis (TB) is the most common cause of death in people living with HIV (PLHIV), yet TB often goes undiagnosed since many patients are not able to produce a sputum specimen, and traditional diagnostics are costly or unavailable. A novel, rapid lateral flow assay, Fujifilm SILVAMP TB LAM (SILVAMP-LAM), detects the presence of TB lipoarabinomannan (LAM) in urine, and is substantially more sensitive for diagnosing TB in PLHIV than an earlier LAM assay (Alere Determine TB LAM lateral flow assay [LF-LAM]). Here, we present an individual participant data meta-analysis of the diagnostic accuracy of SILVAMP-LAM in adult PLHIV, including both published and unpublished data. Adult PLHIV (≥18 years) were assessed in 5 prospective cohort studies in South Africa (3 cohorts), Vietnam, and Ghana, carried out during 2012 to 2017. Of the 1,595 PLHIV who met eligibility criteria, the majority (61%) were inpatients, median age was 37 years (IQR 30–43), 43% had a CD4 count ≤ 100 cells/μl, and 35% were receiving antiretroviral therapy. Most participants (94%) had a positive WHO symptom screen for TB on enrollment, and 45% were diagnosed with microbiologically confirmed TB, using mycobacterial culture or Xpert MTB/RIF testing of sputum, urine, or blood. Previously published data from inpatients were combined with unpublished data from outpatients. Biobanked urine samples were tested, using blinded double reading, with SILVAMP-LAM and LF-LAM. Applying a microbiological reference standard for assessment of sensitivity, the overall sensitivity for TB detection was 70.7% (95% CI 59.0%–80.8%) for SILVAMP-LAM compared to 34.9% (95% CI 19.5%–50.9%) for LF-LAM. Using a composite reference standard (which included patients with both microbiologically confirmed as well as clinically diagnosed TB), SILVAMP-LAM sensitivity was 65.8% (95% CI 55.9%–74.6%), and that of LF-LAM 31.4% (95% CI 19.1%–43.7%). In patients with CD4 count ≤ 100 cells/μl, SILVAMP-LAM sensitivity was 87.1% (95% CI 79.3%–93.6%), compared to 56.0% (95% CI 43.9%–64.9%) for LF-LAM. In patients with CD4 count 101–200 cells/μl, SILVAMP-LAM sensitivity was 62.7% (95% CI 52.4%–71.9%), compared to 25.3% (95% CI 15.8%–34.9%) for LF-LAM. In those with CD4 count > 200 cells/μl, SILVAMP-LAM sensitivity was 43.9% (95% CI 34.3%–53.9%), compared to 10.9% (95% CI 5.2%–18.4%) for LF-LAM. Using a microbiological reference standard, the specificity of SILVAMP-LAM was 90.9% (95% CI 87.2%–93.7%), and that of LF-LAM 95.3% (95% CI 92.2%–97.7%). Limitations of this study include the use of biobanked, rather than fresh urine samples, and testing by skilled laboratory technicians in research laboratories, rather than at the point of care. In this study, we found that SILVAMP-LAM identified a substantially higher proportion of TB patients in PLHIV than LF-LAM. The sensitivity of SILVAMP-LAM was highest in patients with CD4 count ≤ 100 cells/μl. Further work is needed to demonstrate accuracy when implemented as a point-of-care test.