Reena Mehra

Dr. Reena Mehra


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2012 in Journal of Clinical Sleep Medicine
Verified
Journal Article
Closed access
PDF file
RBRichard B. Berry
Richard B. Berry
RBRohit Budhiraja
Rohit Budhiraja
DGDaniel J. Gottlieb
Daniel J. Gottlieb
DGDavid Gozal
David Gozal
CIConrad Iber
Conrad Iber
MTMichelle M. Tangredi
Michelle M. Tangredi
The American Academy of Sleep Medicine (AASM) Sleep Apnea Definitions Task Force reviewed the current rules for scoring respiratory events in the 2007 AASM Manual for the Scoring and Sleep and Associated Events to determine if revision was indicated. The goals of the task force were (1) to clarify and simplify the current scoring rules, (2) to review evidence for new monitoring technologies relevant to the scoring rules, and (3) to strive for greater concordance between adult and pediatric rules. The task force reviewed the evidence cited by the AASM systematic review of the reliability and validity of scoring respiratory events published in 2007 and relevant studies that have appeared in the literature since that publication. Given the limitations of the published evidence, a consensus process was used to formulate the majority of the task force recommendations concerning revisions.The task force made recommendations concerning recommended and alternative sensors for the detection of apnea and hypopnea to be used during diagnostic and positive airway pressure (PAP) titration polysomnography. An alternative sensor is used if the recommended sensor fails or the signal is inaccurate. The PAP device flow signal is the recommended sensor for the detection of apnea, hypopnea, and respiratory effort related arousals (RERAs) during PAP titration studies. Appropriate filter settings for recording (display) of the nasal pressure signal to facilitate visualization of inspiratory flattening are also specified. The respiratory inductance plethysmography (RIP) signals to be used as alternative sensors for apnea and hypopnea detection are specified. The task force reached consensus on use of the same sensors for adult and pediatric patients except for the following: (1) the end-tidal PCO(2) signal can be used as an alternative sensor for apnea detection in children only, and (2) polyvinylidene fluoride (PVDF) belts can be used to monitor respiratory effort (thoracoabdominal belts) and as an alternative sensor for detection of apnea and hypopnea (PVDFsum) only in adults.The task force recommends the following changes to the 2007 respiratory scoring rules. Apnea in adults is scored when there is a drop in the peak signal excursion by ≥ 90% of pre-event baseline using an oronasal thermal sensor (diagnostic study), PAP device flow (titration study), or an alternative apnea sensor, for ≥ 10 seconds. Hypopnea in adults is scored when the peak signal excursions drop by ≥ 30% of pre-event baseline using nasal pressure (diagnostic study), PAP device flow (titration study), or an alternative sensor, for ≥ 10 seconds in association with either ≥ 3% arterial oxygen desaturation or an arousal. Scoring a hypopnea as either obstructive or central is now listed as optional, and the recommended scoring rules are presented. In children an apnea is scored when peak signal excursions drop by ≥ 90% of pre-event baseline using an oronasal thermal sensor (diagnostic study), PAP device flow (titration study), or an alternative sensor; and the event meets duration and respiratory effort criteria for an obstructive, mixed, or central apnea. A central apnea is scored in children when the event meets criteria for an apnea, there is an absence of inspiratory effort throughout the event, and at least one of the following is met: (1) the event is ≥ 20 seconds in duration, (2) the event is associated with an arousal or ≥ 3% oxygen desaturation, (3) (infants under 1 year of age only) the event is associated with a decrease in heart rate to less than 50 beats per minute for at least 5 seconds or less than 60 beats per minute for 15 seconds. A hypopnea is scored in children when the peak signal excursions drop is ≥ 30% of pre-event baseline using nasal pressure (diagnostic study), PAP device flow (titration study), or an alternative sensor, for ≥ the duration of 2 breaths in association with either ≥ 3% oxygen desaturation or an arousal. In children and adults, surrogates of the arterial PCO(2) are the end-tidal PCO(2) or transcutaneous PCO(2) (diagnostic study) or transcutaneous PCO(2) (titration study). For adults, sleep hypoventilation is scored when the arterial PCO(2) (or surrogate) is > 55 mm Hg for ≥ 10 minutes or there is an increase in the arterial PCO(2) (or surrogate) ≥ 10 mm Hg (in comparison to an awake supine value) to a value exceeding 50 mm Hg for ≥ 10 minutes. For pediatric patients hypoventilation is scored when the arterial PCO(2) (or surrogate) is > 50 mm Hg for > 25% of total sleep time. In adults Cheyne-Stokes breathing is scored when both of the following are met: (1) there are episodes of ≥ 3 consecutive central apneas and/or central hypopneas separated by a crescendo and decrescendo change in breathing amplitude with a cycle length of at least 40 seconds (typically 45 to 90 seconds), and (2) there are five or more central apneas and/or central hypopneas per hour associated with the crescendo/decrescendo breathing pattern recorded over a minimum of 2 hours of monitoring.

15 March 2017 in Journal of Clinical Sleep Medicine
Verified
Journal Article
Closed access
VKVishesh K. Kapur
Vishesh K. Kapur
DADennis H. Auckley
Dennis H. Auckley
SCSusmita Chowdhuri
Susmita Chowdhuri
DKDavid C. Kuhlmann
David C. Kuhlmann
RMReena Mehra
Reena Mehra
CHChristopher G. Harrod
Christopher G. Harrod
This guideline establishes clinical practice recommendations for the diagnosis of obstructive sleep apnea (OSA) in adults and is intended for use in conjunction with other American Academy of Sleep Medicine (AASM) guidelines on the evaluation and treatment of sleep-disordered breathing in adults. The AASM commissioned a task force of experts in sleep medicine. A systematic review was conducted to identify studies, and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) process was used to assess the evidence. The task force developed recommendations and assigned strengths based on the quality of evidence, the balance of benefits and harms, patient values and preferences, and resource use. In addition, the task force adopted foundational recommendations from prior guidelines as "good practice statements", that establish the basis for appropriate and effective diagnosis of OSA. The AASM Board of Directors approved the final recommendations. The following recommendations are intended as a guide for clinicians diagnosing OSA in adults. Under GRADE, a STRONG recommendation is one that clinicians should follow under most circumstances. A WEAK recommendation reflects a lower degree of certainty regarding the outcome and appropriateness of the patient-care strategy for all patients. The ultimate judgment regarding propriety of any specific care must be made by the clinician in light of the individual circumstances presented by the patient, available diagnostic tools, accessible treatment options, and resources. Good Practice Statements: Diagnostic testing for OSA should be performed in conjunction with a comprehensive sleep evaluation and adequate follow-up. Polysomnography is the standard diagnostic test for the diagnosis of OSA in adult patients in whom there is a concern for OSA based on a comprehensive sleep evaluation.Recommendations: We recommend that clinical tools, questionnaires and prediction algorithms not be used to diagnose OSA in adults, in the absence of polysomnography or home sleep apnea testing. (STRONG). We recommend that polysomnography, or home sleep apnea testing with a technically adequate device, be used for the diagnosis of OSA in uncomplicated adult patients presenting with signs and symptoms that indicate an increased risk of moderate to severe OSA. (STRONG). We recommend that if a single home sleep apnea test is negative, inconclusive, or technically inadequate, polysomnography be performed for the diagnosis of OSA. (STRONG). We recommend that polysomnography, rather than home sleep apnea testing, be used for the diagnosis of OSA in patients with significant cardiorespiratory disease, potential respiratory muscle weakness due to neuromuscular condition, awake hypoventilation or suspicion of sleep related hypoventilation, chronic opioid medication use, history of stroke or severe insomnia. (STRONG). We suggest that, if clinically appropriate, a split-night diagnostic protocol, rather than a full-night diagnostic protocol for polysomnography be used for the diagnosis of OSA. (WEAK). We suggest that when the initial polysomnogram is negative and clinical suspicion for OSA remains, a second polysomnogram be considered for the diagnosis of OSA. (WEAK).

1 February 2017 in JACC
Verified
Journal Article
Closed access
SJShahrokh Javaheri
Shahrokh Javaheri
FBFerran Barbe
Ferran Barbe
FGFrancisco Garcia-Rio
Francisco Garcia-Rio
JDJerome A. Dempsey
Jerome A. Dempsey
RKRami Khayat
Rami Khayat
VSVirend K. Somers
Virend K. Somers

15 April 2006 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
RMReena Mehra
Reena Mehra
Emelia J. BenjaminEmelia J. Benjamin
Emelia J. Benjamin
ESEyal Shahar
Eyal Shahar
DGDaniel J. Gottlieb
Daniel J. Gottlieb
RNRawan Nawabit
Rawan Nawabit
SRSusan Redline
Susan Redline
Rationale: Sleep-disordered breathing recurrent intermittent hypoxia and sympathetic nervous system activity surges provide the milieu for cardiac arrhythmia development. Objective: We postulate that the prevalence of nocturnal cardiac arrhythmias is higher among subjects with than without sleep-disordered breathing. Methods: The prevalence of arrhythmias was compared in two samples of participants from the Sleep Heart Health Study frequency-matched on age, sex, race/ethnicity, and body mass index: (1) 228 subjects with sleep-disordered breathing (respiratory disturbance index ⩾ 30) and (2) 338 subjects without sleep-disordered breathing (respiratory disturbance index < 5). Results: Atrial fibrillation, nonsustained ventricular tachycardia, and complex ventricular ectopy (nonsustained ventricular tachycardia or bigeminy or trigeminy or quadrigeminy) were more common in subjects with sleep-disordered breathing compared with those without sleep-disordered breathing: 4.8 versus 0.9% (p = 0.003) for atrial fibrillation; 5.3 versus 1.2% (p = 0.004) for nonsustained ventricular tachycardia; 25.0 versus 14.5% (p = 0.002) for complex ventricular ectopy. Compared with those without sleep-disordered breathing and adjusting for age, sex, body mass index, and prevalent coronary heart disease, individuals with sleep-disordered breathing had four times the odds of atrial fibrillation (odds ratio [OR], 4.02; 95% confidence interval [CI], 1.03–15.74), three times the odds of nonsustained ventricular tachycardia (OR, 3.40; 95% CI, 1.03–11.20), and almost twice the odds of complex ventricular ectopy (OR, 1.74; 95% CI, 1.11–2.74). A significant relation was also observed between sleep-disordered breathing and ventricular ectopic beats/h (p < 0.0003) considered as a continuous outcome. Conclusions: Individuals with severe sleep-disordered breathing have two- to fourfold higher odds of complex arrhythmias than those without sleep-disordered breathing even after adjustment for potential confounders.

15 October 2011 in Journal of Clinical Sleep Medicine
Verified
Journal Article
Closed access
NCNancy A. Collop
Nancy A. Collop
STSharon L. Tracy
Sharon L. Tracy
VKVishesh Kapur
Vishesh Kapur
RMReena Mehra
Reena Mehra
DKDavid Kuhlmann
David Kuhlmann
JOJoseph M. Ojile
Joseph M. Ojile
Guidance is needed to help clinicians decide which out-of-center (OOC) testing devices are appropriate for diagnosing obstructive sleep apnea (OSA). A new classification system that details the type of signals measured by these devices is presented. This proposed system categorizes OOC devices based on measurements of Sleep, Cardiovascular, Oximetry, Position, Effort, and Respiratory (SCOPER) parameters.Criteria for evaluating the devices are also presented, which were generated from chosen pre-test and post-test probabilities. These criteria state that in patients with a high pretest probability of having OSA, the OOC testing device has a positive likelihood ratio (LR+) of 5 or greater coinciding with an in-lab-polysomnography (PSG)-generated apnea hypopnea index (AHI) ≥ 5, and an adequate sensitivity (at least 0.825).Since oximetry is a mandatory signal for scoring AHI using PSG, devices that do not incorporate oximetry were excluded. English peer-reviewed literature on FDA-approved devices utilizing more than 1 signal was reviewed according to the above criteria for 6 questions. These questions specifically addressed the adequacy of different respiratory and effort sensors and combinations thereof to diagnose OSA. In summary, the literature is currently inadequate to state with confidence that a thermistor alone without any effort sensor is adequate to diagnose OSA; if a thermal sensing device is used as the only measure of respiration, 2 effort belts are required as part of the montage and piezoelectric belts are acceptable in this context; nasal pressure can be an adequate measurement of respiration with no effort measure with the caveat that this may be device specific; nasal pressure may be used in combination with either 2 piezoelectric or respiratory inductance plethysmographic (RIP) belts (but not 1 piezoelectric belt); and there is insufficient evidence to state that both nasal pressure and thermistor are required to adequately diagnose OSA. With respect to alternative devices for diagnosing OSA, the data indicate that peripheral arterial tonometry (PAT) devices are adequate for the proposed use; the device based on cardiac signals shows promise, but more study is required as it has not been tested in the home setting; for the device based on end-tidal CO(2) (ETCO(2)), it appears to be adequate for a hospital population; and for devices utilizing acoustic signals, the data are insufficient to determine whether the use of acoustic signals with other signals as a substitute for airflow is adequate to diagnose OSA.Standardized research is needed on OOC devices that report LR+ at the appropriate AHI (≥ 5) and scored according to the recommended definitions, while using appropriate research reporting and methodology to minimize bias.

12 June 2014 in New England Journal of Medicine
Verified
Journal Article
Open access
PDF file
DGDaniel J. Gottlieb
Daniel J. Gottlieb
NPNaresh M. Punjabi
Naresh M. Punjabi
RMReena Mehra
Reena Mehra
SPSanjay Patel
Sanjay Patel
SQStuart F. Quan
Stuart F. Quan
SRSusan Redline
Susan Redline
Obstructive sleep apnea is associated with hypertension, inflammation, and increased cardiovascular risk. Continuous positive airway pressure (CPAP) reduces blood pressure, but adherence is often suboptimal, and the benefit beyond management of conventional risk factors is uncertain. Since intermittent hypoxemia may underlie cardiovascular sequelae of sleep apnea, we evaluated the effects of nocturnal supplemental oxygen and CPAP on markers of cardiovascular risk. We conducted a randomized, controlled trial in which patients with cardiovascular disease or multiple cardiovascular risk factors were recruited from cardiology practices. Patients were screened for obstructive sleep apnea with the use of the Berlin questionnaire, and home sleep testing was used to establish the diagnosis. Participants with an apnea–hypopnea index of 15 to 50 events per hour were randomly assigned to receive education on sleep hygiene and healthy lifestyle alone (the control group) or, in addition to education, either CPAP or nocturnal supplemental oxygen. Cardiovascular risk was assessed at baseline and after 12 weeks of the study treatment. The primary outcome was 24-hour mean arterial pressure. Of 318 patients who underwent randomization, 281 (88%) could be evaluated for ambulatory blood pressure at both baseline and follow-up. On average, the 24-hour mean arterial pressure at 12 weeks was lower in the group receiving CPAP than in the control group (−2.4 mm Hg; 95% confidence interval [CI], −4.7 to −0.1; P=0.04) or the group receiving supplemental oxygen (−2.8 mm Hg; 95% CI, −5.1 to −0.5; P=0.02). There was no significant difference in the 24-hour mean arterial pressure between the control group and the group receiving oxygen. A sensitivity analysis performed with the use of multiple imputation approaches to assess the effect of missing data did not change the results of the primary analysis. In patients with cardiovascular disease or multiple cardiovascular risk factors, the treatment of obstructive sleep apnea with CPAP, but not nocturnal supplemental oxygen, resulted in a significant reduction in blood pressure. (Funded by the National Heart, Lung, and Blood Institute and others; HeartBEAT ClinicalTrials.gov number, NCT01086800.)