David P. Arnold

Prof. Dr. David P. Arnold

Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL 32611-6200, USA
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2018 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
HBHunter C. Burch
Hunter C. Burch
AGAlexandra Garraud
Alexandra Garraud
MMMichael F. Mitchell
Michael F. Mitchell
RMRobert C. Moore
Robert C. Moore
David P. ArnoldDavid P. Arnold
David P. Arnold
This paper presents a simple, compact, and low-power method for generating extremely low-frequency radio signals below ~500 Hz. This paper is motivated by the prohibitively large size and low efficiency of conventional antennas operating in this frequency range. The successful generation of time-varying magnetic fields produced by the physical rotation of a 3 cm 3 permanent magnet is demonstrated. Ground plane and receiver orientation effects are analyzed both theoretically and experimentally. Observations as a function of distance from the source indicate that the fields are dominated by the static component, rather than by the radiation component, of the generated field. Based on these observations, the electromagnetic radiation emitted by a spinning magnet source is predicted to be weak. Nevertheless, static magnetic signaling using this technique is proven to be both possible and practical at frequencies below ~500 Hz and at distances in excess of 100 m.

25 January 2023 in Science Robotics
Verified
Journal Article
Closed access
EMErfan Mohagheghian
Erfan Mohagheghian
JLJunyu Luo
Junyu Luo
FYF. Max Yavitt
F. Max Yavitt
FWFuxiang Wei
Fuxiang Wei
PBParth Bhala
Parth Bhala
NWNing Wang
Ning Wang
Stiffness and forces are two fundamental quantities essential to living cells and tissues. However, it has been a challenge to quantify both 3D traction forces and stiffness (or modulus) using the same probe in vivo. Here, we describe an approach that overcomes this challenge by creating a magnetic microrobot probe with controllable functionality. Biocompatible ferromagnetic cobalt-platinum microcrosses were fabricated, and each microcross (about 30 micrometers) was trapped inside an arginine–glycine–aspartic acid–conjugated stiff poly(ethylene glycol) (PEG) round microgel (about 50 micrometers) using a microfluidic device. The stiff magnetic microrobot was seeded inside a cell colony and acted as a stiffness probe by rigidly rotating in response to an oscillatory magnetic field. Then, brief episodes of ultraviolet light exposure were applied to dynamically photodegrade and soften the fluorescent nanoparticle–embedded PEG microgel, whose deformation and 3D traction forces were quantified. Using the microrobot probe, we show that malignant tumor–repopulating cell colonies altered their modulus but not traction forces in response to different 3D substrate elasticities. Stiffness and 3D traction forces were measured, and both normal and shear traction force oscillations were observed in zebrafish embryos from blastula to gastrula. Mouse embryos generated larger tensile and compressive traction force oscillations than shear traction force oscillations during blastocyst. The microrobot probe with controllable functionality via magnetic fields could potentially be useful for studying the mechanoregulation of cells, tissues, and embryos.

26 April 2019 in Journal of Microelectromechanical Systems
Verified
Journal Article
Open access
ATAnthony P. Taylor
Anthony P. Taylor
CCCamilo Velez Cuervo
Camilo Velez Cuervo
David P. ArnoldDavid P. Arnold
David P. Arnold
Luis Fernando Velásquez-GarcíaLuis Fernando Velásquez-García
Luis Fernando Velásquez-García
We report the design, fabrication, and experimental characterization of the first fully 3D-printed, multi-material miniature magnetic actuators for compact systems in the literature. The actuator design integrates a bonded hard magnet made of NdFeB microparticles embedded in a Nylon 12 matrix (55% by volume) with structural and support elements made of pure Nylon 12. The device is a 10 mm-diameter, 1.2 mm wall-thick, and 9 mm tall cylindrical frame that mounts on an off-the-shelf solenoid and a 10 mm diameter, 100 μm-thick, leak-tight membrane connected at its center to a 4 mm diameter, 4.95 mm tall hard magnet. The actuators are monolithically printed in layers as thin as 100 μm using 600 μm-wide strokes via fused filament fabrication (FFF) -a low-cost 3D printing technology capable of processing high-performance thermoplastics to create monolithic objects made of a plurality of distinctive feedstock. The average surface roughness, Young's modulus, and hardness of the FFF-printable hard-magnetic filament were estimated at 58.55 μm, 3.59 GPa, and Shore D 71.5, respectively, while the average surface roughness, Young's modulus, and yield strength of FFF-printed magnetic material were estimated at 5.79 μm, 2.02 GPa, and 55.99 MPa ± 4.59 MPa, respectively. Magnetic characterization of the FFF-printed NdFeB-embedded Nylon 12 feedstock demonstrates the fabrication of isotropic hard magnets with an intrinsic coercivity of ~ 700 kA/m, remanence of ~ 395 mT, and a maximum energy product of 27 kJ/m³. Simulations of the stray magnetic field produced by a printed sample made of NdFeB-embedded Nylon 12 were validated using a scanning Hall probe. The vertical displacement of a miniature 3D-printed magnetic actuator was characterized with a solenoid for various coil bias voltages; a maximum displacement equal to 50 μm was obtained with 3.1 V DC applied to the driving coil. Finite element simulations of the actuator design estimate at 2.38 MPa the maximum stress on the membrane at 50 μm actuation (i.e., below the fatigue limit of Nylon 12), and at 592.61 Hz the natural frequency of the device, which was corroborated via experiment. [2018-0288]

22 September 2020 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
RBRenuka Bowrothu
Renuka Bowrothu
HKHae-In Kim
Hae-In Kim
CSConnor S. Smith
Connor S. Smith
David P. ArnoldDavid P. Arnold
David P. Arnold
YYYong-Kyu Yoon
Yong-Kyu Yoon
We report a self-biased, low-profile circulator operating in the Ka-band fabricated by an entirely low-temperature (70 °C) screen-printing approach on printed circuit board (PCB). The magnetic material for the circulator is a barium hexaferrite BaFe12O19 (BaM)/polydimethylsiloxane (PDMS) nanocomposite that exhibits a zero-bias ferromagnetic resonance frequency (fFMR) at 46.6 GHz. Using this material, a microstrip-based circulator operating at 35 GHz is designed, fabricated, and characterized. A combination of mechanical milling, screen printing, photolithography, and electroplating is used for fabricating the circulator, in which the circulator disk (diameter of 2 mm and thickness of 250 μm) is completely embedded in the PCB, realizing a packaging compatible low-profile architecture with the total device area of 33 mm². The measured isolation (IS) and insertion loss (IL) of the fabricated circulator at 35 GHz is 3.9 and 8.7 dB, respectively. When the additional magnetic bias is applied to the circulator using external permanent magnets, the IS and IL performance is improved to be 7.4 and 8.4 dB, respectively. The impact of the loss factors associated with dielectric loss and surface roughness on the device performance is analyzed using High Frequency Structural Simulator (HFSS).

24 September 2015 in ACS Nano
Verified
Journal Article
Closed access
CCCamilo Velez Cuervo
Camilo Velez Cuervo
ITIsaac Torres-Díaz
Isaac Torres-Díaz
LMLorena Maldonado-Camargo
Lorena Maldonado-Camargo
CRCarlos Rinaldi
Carlos Rinaldi
David P. ArnoldDavid P. Arnold
David P. Arnold

1 January 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
ZZZhiyuan Zhao
Zhiyuan Zhao
NGNicolas Garraud
Nicolas Garraud
David P. ArnoldDavid P. Arnold
David P. Arnold
CRCarlos Rinaldi
Carlos Rinaldi
The dynamic magnetization of immobilized spherical single-domain magnetic nanoparticles (MNPs) with uniaxial or cubic magnetocrystalline anisotropy was studied computationally by executing simulations based on the Landau–Lifshitz–Gilbert (LLG) equation. For situations when a static magnetic field was suddenly applied and then removed, the effects of particle diameter and anisotropy (considering both type of symmetry and characteristic energy) on the characteristic magnetic relaxation time were studied parametrically. The results, for both anisotropy symmetries, show that when a static magnetic field is suddenly turned on or off the MNPs undergo a successive two-step or combined one-step relaxation. Whether a MNP relaxes with one or two steps when the field is turned on is determined by the competition between the energy of the applied magnetic field, the magnetic anisotropy energy, and thermal energy. When the applied magnetic field is suddenly turned off, our results show good agreement with theoretical predictions for the cases of and , where represents the magnetic anisotropy energy barrier, is the Boltzmann constant and represents the absolute temperature. For the case of an applied alternating magnetic field (AMF) that is typical of magnetic particle imaging (MPI) applications, the effects of particle diameter and anisotropy symmetry were studied in terms of time-domain magnetization dynamics, dynamic hysteresis loops, harmonic spectra, and x-space point spread functions (PSFs). Results illustrate that the type of magnetocrystalline anisotropy (uniaxial versus cubic) has a significant effect on the MPI performance of the nanoparticles. These computational studies provide insight into the role of particle diameter and magnetic anisotropy on the performance of MNPs for applications in magnetorelaxometry and MPI.