Fabien SAUVET

Dr. Fabien SAUVET

IRBA, Unité de Toxicologie Analytique, D19, 91220 BRETIGNY-SUR-ORGE (France)
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2020 in SLEEP
Verified
Journal Article
Open access
PDF file
PAPierrick J Arnal
Pierrick J Arnal
VTValentin Thorey
Valentin Thorey
EDEden Debellemaniere
Eden Debellemaniere
MBMichael E Ballard
Michael E Ballard
AHAlbert Bou Hernandez
Albert Bou Hernandez
FSFabien SAUVET
Fabien SAUVET
Study Objectives: The development of ambulatory technologies capable of monitoring brain activity during sleep longitudinally is critical for advancing sleep science. The aim of this study was to assess the signal acquisition and the performance of the automatic sleep staging algorithms of a reduced-montage dry-electroencephalographic (EEG) device (Dreem headband, DH) compared to the gold-standard polysomnography (PSG) scored by five sleep experts. Methods: A total of 25 subjects who completed an overnight sleep study at a sleep center while wearing both a PSG and the DH simultaneously have been included in the analysis. We assessed (1) similarity of measured EEG brain waves between the DH and the PSG; (2) the heart rate, breathing frequency, and respiration rate variability (RRV) agreement between the DH and the PSG; and (3) the performance of the DH’s automatic sleep staging according to American Academy of Sleep Medicine guidelines versus PSG sleep experts manual scoring. Results: The mean percentage error between the EEG signals acquired by the DH and those from the PSG for the monitoring of α was 15 ± 3.5%, 16 ± 4.3% for β, 16 ± 6.1% for λ, and 10 ± 1.4% for θ frequencies during sleep. The mean absolute error for heart rate, breathing frequency, and RRV was 1.2 ± 0.5 bpm, 0.3 ± 0.2 cpm, and 3.2 ± 0.6%, respectively. Automatic sleep staging reached an overall accuracy of 83.5 ± 6.4% (F1 score: 83.8 ± 6.3) for the DH to be compared with an average of 86.4 ± 8.0% (F1 score: 86.3 ± 7.4) for the 5 sleep experts. Conclusions: These results demonstrate the capacity of the DH to both monitor sleep-related physiological signals and process them accurately into sleep stages. This device paves the way for, large-scale, longitudinal sleep studies. Clinical Trial Registration: NCT03725943.

1 October 2020 in Sleep Medicine
Verified
Journal Article
Closed access
Damien LEGERDamien LEGER
Damien LEGER
JRJean-Baptiste Richard
Jean-Baptiste Richard
OCOlivier Collin
Olivier Collin
FSFabien SAUVET
Fabien SAUVET
BFBrice Faraut
Brice Faraut

1 July 2015 in International Journal of Cardiology
Verified
Journal Article
Closed access
FSFabien SAUVET
Fabien SAUVET
CDCatherine Drogou
Catherine Drogou
CBClément Bougard
Clément Bougard
PAPierrick J. Arnal
Pierrick J. Arnal
GDGarance Dispersyn
Garance Dispersyn
MCMounir Chennaoui
Mounir Chennaoui

3 March 2017 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
MEMAXIME ELBAZ
MAXIME ELBAZ
Damien LEGERDamien LEGER
Damien LEGER
FSFabien SAUVET
Fabien SAUVET
BCBenoit Champigneulle
Benoit Champigneulle
SRStéphane Rio
Stéphane Rio
JMJean Paul Mira
Jean Paul Mira
It is well recognized that sleep is severely disturbed in patients in intensive care units (ICU) and that this can compromise their rehabilitation potential. However, it is still difficult to objectively assess sleep quantity and quality and the determinants of sleep disturbance remain unclear. The aim of this study was therefore to evaluate carefully the impact of ICU sound intensity levels and their sources on ICU patients’ sleep over a 24-h period. Sleep and sound levels were recorded in 11 ICU intubated patients who met the criteria. Sleep was recorded using a miniaturized multi-channel ambulatory recording device. Sound intensity levels and their sources were recorded with the Nox-T3 monitor. A 30-s epoch-by-epoch analysis of sleep stages and sound data was carried out. Multinomial and binomial logistic regressions were used to associate sleep stages, wakefulness and sleep–wake transitions with sound levels and their sources. The subjects slept a median of 502.2 [283.2–718.9] min per 24 h; 356.9 [188.6–590.9] min at night (22.00–08.00) and 168.5 [142.5–243.3] during daytime (8 am–10 pm). Median sound intensity level reached 70.2 [65.1–80.3] dBC at night. Sound thresholds leading to disturbed sleep were 63 dBC during the day and 59 dBC during the night. With levels above 77 dBC, the incidence of arousals (OR 3.9, 95% CI 3.0–5.0) and sleep-to-wake transitions (OR 7.6, 95% CI 4.1–14) increased. The most disturbing noises sources were monitor alarms (OR 4.5, 95% CI 3.5–5.6) and ventilator alarms (OR 4.2, 95% CI 2.9–6.1). We have shown, in a small group of 11 non-severe ICU patients, that sound level intensity, a major disturbance factor of sleep continuity, should be strictly controlled on a 24-h profile.

6 December 2019 in Genes
Verified
Journal Article
Open access
PDF file
EMERBLANG Mégane
ERBLANG Mégane
CDCatherine DROGOU
Catherine DROGOU
DGdanielle gomez-merino
danielle gomez-merino
AMarnaud Metlaine
arnaud Metlaine
ABAnne Boland
Anne Boland
MCMounir Chennaoui
Mounir Chennaoui
ADORA2A has been shown to be responsible for the wakefulness-promoting effect of caffeine and the 1976T>C genotype (SNP rs5751876, formerly 1083T>C) to contribute to individual sensitivity to caffeine effects on sleep. We investigate the association between six single nucleotide polymorphisms (SNP) from ADORA2A and self-reported sleep characteristics and caffeine consumption in 1023 active workers of European ancestry aged 18–60 years. Three groups of caffeine consumers were delineated: low (0–50 mg/day, less than one expresso per day), moderate (51–300 mg/day), and high (>300 mg/day). We found that at caffeine levels higher than 300 mg/day, total sleep time (TST) decreased (F = 13.9, p < 0.01), with an increase of insomnia (ORa [95%CI] = 1.5 [1.1–1.9]) and sleep complaints (ORa [95%CI] = 1.9 [1.1–3.3]), whatever the ADORA2A polymorphism. Odds ratios were adjusted (ORa) for sex, age, and tobacco. However, in low caffeine consumers, lower TST was observed in the T allele compared to homozygote rs5751876 and rs3761422 C carriers. Conversely, higher TST was observed in rs2298383 T allele compared to C and in rs4822492G allele compared to the homozygote C (p < 0.05). These 4 SNPs are in strong linkage disequilibrium. Haplotype analysis confirmed the influence of multiple ADORA2a SNPs on TST. In addition, the rs2298383 T and rs4822492 G alleles were associated with higher risk of sleep complaints (Ora = 1.9 [1.2–3.1] and Ora = 1.5 [1.1–2.1]) and insomnia (Ora = 1.5 [1.3–2.5] and Ora = 1.9 [1.3–3.2). The rs5751876 T allele was associated with a decreased risk of sleep complaints (Ora = 0.7 [0.3–0.9]) and insomnia (Ora = 0.5 [0.3–0.9]). Our results identified ADORA2A polymorphism influences in the less-than-300-mg-per-day caffeine consumers. This opens perspectives on the diagnosis and pharmacology of sleep complaints and caffeine chronic consumption.

1 October 2021 in Brain Sciences
Verified
Journal Article
Open access
PDF file
ESEmeric SAGUIN
Emeric SAGUIN
DGdanielle gomez-merino
danielle gomez-merino
FSFabien SAUVET
Fabien SAUVET
Damien LEGERDamien LEGER
Damien LEGER
MCMounir Chennaoui
Mounir Chennaoui
Sleep disturbances are well-recognised symptoms of Post-Traumatic Stress Disorder (PTSD). This review updates knowledge regarding the relationship between sleep during deployment, combat-related trauma, and PTSD in military personnel, from which the importance of restorative sleep results. The description of the characteristics of sleep in military forces with the considerable roles of the operational and training contexts highlights the important consequences of degraded sleep. Indeed, a lot of data suggest a dynamic link between sleep and the onset and chronicity of PTSD. We propose a reciprocal relationship model with strategies strongly recommended or already adopted by the military to promote restorative sleep before and after combat exposure. Among the alterations in a variety of sleep architecture and sleep patterns described in PTSD, the physiological hypothesis of REM sleep fragmentation in the development of PTSD symptoms may be important because REM sleep is generally associated with emotional memory. Finally, we address clinical and research perspectives that could be used to detect or restore sleep continuity before and during military deployment to possibly alleviate nightmares and insomnia related to combat exposure and PTSD occurrence and improve our understanding of sleep in PTSD.