Sebastian Bürklein

Prof. Dr. Sebastian Bürklein

Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, Münster, Germany
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2019 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
Sebastian BürkleinSebastian Bürklein
Sebastian Bürklein
ESEdgar Schäfer
Edgar Schäfer
HJHans-Peter Jöhren
Hans-Peter Jöhren
DDDavid Donnermeyer
David Donnermeyer

19 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
David DonnermeyerDavid Donnermeyer
David Donnermeyer
PSPatrick Schemkämper
Patrick Schemkämper
Sebastian BürkleinSebastian Bürklein
Sebastian Bürklein
Edgar SchäferEdgar Schäfer
Edgar Schäfer
This study aimed to investigate the short- and long-term solubility, alkalizing potential, and suitability for warm-vertical compaction of AH Plus Bioceramic Sealer (AHBC), and Total Fill BC Sealer (TFBC) compared to the epoxy-resin sealer AH Plus (AHP). A solubility test was performed according to ISO specification 6876 and further similar to ISO requirements over a period of 1 month in distilled water (AD) and 4 months in phosphate-buffered saline (PBS). The pH of the immersion solution was determined weekly. Sealers were exposed to thermal treatment at 37, 57, 67, and 97 °C for 30 s. Furthermore, heat treatment at 97 °C was performed for 180 s to simulate inappropriate implementation of warm vertical filling techniques. Physical properties (setting time, flow, film thickness according to ISO 6876) and chemical properties (Fourier transformed infrared spectroscopy) were assessed. AHBC and TFBC were associated with significantly higher solubility than AHP over 1 month in AD and 4 months in PBS (p < 0.05). AHBC and TFBC both reached high initial alkaline pH, while TFBC was associated with a longer-lasting alkaline potential than AHBC. Initial pH of AHBC and TFBC was higher in AD than in PBS. None of the sealers were compromised by thermal treatment.

10 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
David DonnermeyerDavid Donnermeyer
David Donnermeyer
SSSina Schmidt
Sina Schmidt
ARArno Rohrbach
Arno Rohrbach
JBJohannes Berlandi
Johannes Berlandi
Sebastian BürkleinSebastian Bürklein
Sebastian Bürklein
Edgar SchäferEdgar Schäfer
Edgar Schäfer
The aim of this study was to investigate the suitability of rhodamine B dye staining of an epoxy resin sealer (AH Plus) and calcium-silicate-based sealers (Total Fill BC Sealer, BioRoot RCS) to represent the penetration depth of the sealers into dentinal tubules after root canal obturation. In a three-step process, (1) leaching of rhodamine B from sealers into a buffer solution, (2) passive penetration of leached rhodamine B into dentinal tubules, and (3) conformity of rhodamine B penetration assessed by confocal laser scanning microscopy (CLSM), and sealer penetration assessed by scanning electron microscopy (SEM), in root-canal-filled teeth, were evaluated. Rhodamine B dye massively leached out of Total Fill BC Sealer and BioRoot RCS into the phosphate-buffered saline (PBS). A pinkish coloration of AH Plus was found after contact with PBS. Leached rhodamine B dye passively penetrated dentinal tubules from all three sealers when placed on root dentin. No correlation was observed between sealer penetration in SEM and rhodamine B penetration in CLSM. Staining of sealers using rhodamine B is an inadequate method with which to evaluate sealer penetration depth into dentinal tubules, as it overestimates the penetration of sealers into root dentin tubules.

27 March 2020 in International Endodontic Journal
Verified
Journal Article
Open access
PDF file
AHA. Hanafi
A. Hanafi
David DonnermeyerDavid Donnermeyer
David Donnermeyer
Edgar SchäferEdgar Schäfer
Edgar Schäfer
Sebastian BürkleinSebastian Bürklein
Sebastian Bürklein
Aim: To evaluate a modular 3D print training dental model with embedded human teeth and electronic working length determination for undergraduate endodontic education.Methodology: Cone‐beam volume tomography data of a human skull were transferred into stereolithographic (STL) data, and a customizable modular 3D print model with individually removable sextants and teeth was generated for the use in commercially available phantom heads. Each of sixty‐eight students performed a complete root canal treatment on an extracted human tooth. Working lengths were determined with electronic apex locators (EAL) and verified radiographically. Subsequently, an evaluation was carried out with regard to the difficulty of the working steps access cavity preparation, working length determination, root canal preparation/irrigation and canal filling, and these steps were compared to commonly used benchtop models. Additionally, the agreement of electronic and radiographic working length determination was assessed and analysed statistically with the chi‐square test.Results: A total of 68 teeth (20 incisors, 26 premolars and 22 molars) with 127 root canals were treated. In total, 87% of the students considered the modular 3D print model considerably more demanding than the conventional benchtop model. Overall, 96% felt better prepared for the clinical situation, 92% felt markedly reduced stress levels during endodontic practice in the subsequent clinical courses, and 93% of the students suggested the model should be used in future preclinical endodontic training. The preradiographic use of EAL resulted in 85% of the cases having radiographically acceptable working length determination within 0–2 mm from the radiographic apex. Readings more than 2 mm from the apex or beyond were significantly more common in molars than in premolars and incisors (P < 0.05).Conclusions: The vast majority of students rated the modular 3D print training model positively despite it being more demanding. They also recommended its use in preclinical teaching and training. The model allowed a more realistic simulation of the clinical situation with a simultaneous use of EALs and led to reduced stress levels in endodontic treatment in the subsequent clinical courses.

23 June 2022 in International Endodontic Journal
Verified
Journal Article
Open access
Sebastian BürkleinSebastian Bürklein
Sebastian Bürklein
AAAna Arias
Ana Arias
Background: The development of endodontic instruments has rapidly advanced, but their impact on endodontic outcome parameters remains unclear.Objectives: This systematic review aimed to answer the following PICOT questions: In patients with apical periodontitis (P) what is the effectiveness of root canal instrumentation ([Q1] performed with contemporary techniques [I] in comparison with ‘traditional’ techniques [C]] and ([Q2] performed with contemporary engine‐driven NiTi instruments [I] compared with other types of contemporary engine‐driven NiTi instruments [with different design and/or technology] [C]) in terms of clinical and patient‐related outcomes (O)?Methods: After PROSPERO protocol registration, a literature search was conducted using Clarivate Analytics' Web of Science, Scopus, PubMed and Cochrane Central Register of Controlled Trials. Grey literature and major journal contents were examined. Two independent reviewers performed the study selection, data extraction and appraisal of included studies. A quantitative meta‐analysis was considered, and statistical heterogeneity and overall quality of evidence were assessed.Results: Nine studies were identified showing substantial methodological differences. Five studies addressed PICOT 1 and three PICOT 2, whereas one study aimed both. A random‐effects meta‐analysis model was considered for the outcome ‘radiographic evidence of normal periodontal ligament space or reduction of apical lesion size’ (PICOT 1) based on three studies with 332 evaluable participants and showed that contemporary instrumentation was associated with a more favourable outcome (p = .005) compared with root canal preparation with stainless steel instruments (odds ratio = 2.07 [95%‐confidence interval = 1.25–3.44]) with no evidence of statistical heterogeneity (I2 = 0%) but low quality of evidence.Discussion: Albeit a few studies fulfilled eligible criteria, no study had a low risk of bias. Compelling evidence indicating significantly different outcome rates using different endodontic instruments when treating teeth with apical periodontitis is lacking.Conclusions: In terms of healing, the results of the meta‐analysis determined the higher effectiveness of root canal instrumentation performed with contemporary techniques in comparison with conventional stainless steel instruments in patients with apical periodontitis followed for a minimum of 1 year with low quality of evidence. No differences could be demonstrated between preparations with traditional stainless steel and contemporary NiTi instruments for other clinical and patient‐related outcomes.Registration: PROSPERO (CRD42021274642).

1 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
Sebastian BürkleinSebastian Bürklein
Sebastian Bürklein
LZLennart Zupanc
Lennart Zupanc
David DonnermeyerDavid Donnermeyer
David Donnermeyer
KTKarsten Tegtmeyer
Karsten Tegtmeyer
Edgar SchäferEdgar Schäfer
Edgar Schäfer
Instrument failure during root canal preparation is still a concern among endodontists. However, it remains unclear whether the use of more martensitic alloys or the cross-sectional design parameters (i.e., core mass) significantly improve fracture resistance. The aim of the study was to evaluate the impact of core mass and alloy on dynamic cyclic fatigue resistance of nickel-titanium endodontic instruments in matching artificial canals at body temperature. Two groups were tested. (A) taper 0.04: F360 (Komet, Lemgo, Germany), Twisted file (Sybron Endo, Glendora, CA, USA) (=TF), JIZAI (Mani, Tochigi, Japan) (=J_04) (all size #25) and the variable tapered TruNatomy (Dentsply, Ballaigues, Switzerland) (size #26) (=TN). (B) size #25; taper 0.06: (Mtwo (VDW, Munich, Germany), JIZAI (Mani) (=J_06), and variable tapered Hyflex EDM OneFile (Coltene Whaledent, Altstätten, Switzerland) (=HF). Time, number of cycles to fracture (NCF), and number and length of fractured fragments were recorded and statistically analysed using ANOVA Student-Newman-Keuls, Kruskal–Wallis or Chi-square test (significance level = 0.05). (A) TN showed the significantly shortest time until fracture, followed by TF, F360 and J_04 which also differed significantly, while NCF showed the following order: F360 < TN < TF < J_04 (p < 0.05). Only one J_04 but all instruments of the other groups fractured within the test-limit of 10 min. (B) Mtwo was significantly inferior concerning time until fracture and NCF, compared to J_06 and HF (p < 0.05), which did not differ significantly (p > 0.05). While all Mtwo instruments fractured, only four instruments failed in the other groups (p < 0.05). Within the limitations of this study, alloy and cross-sectional design (i.e., core mass) were critical factors regarding instrument failure, but none of these factors could be determined as a main parameter for increased or decreased time, and cycles to fracture. Rather, it seemed to be the interaction of multiple factors (e.g., longitudinal and cross-sectional design, alloy, and rotational speed) that was responsible for differences in the time and cycles to fracture. Nonetheless, all instruments had lifetimes that allow safe clinical use. However, the superiority or inferiority of an instrument with regard to cyclic fatigue based on laboratory results—even when identical trajectories are guaranteed—may be considered questionable, as the characteristics and design parameters of the instruments vary considerably, and the experimental setups lack additional clinical parameters and thus clinical relevance.