Jaesung Jang

Dr. Jaesung Jang

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RSRenu Singh
Renu Singh
SHSeongkyeol Hong
Seongkyeol Hong
JJJaesung Jang
Jaesung Jang
Reduced graphene oxide (RGO) has recently gained considerable attention for use in electrochemical biosensing applications due to its outstanding conducting properties and large surface area. This report presents a novel microfluidic chip integrated with an RGO-based electrochemical immunosensor for label-free detection of an influenza virus, H1N1. Three microelectrodes were fabricated on a glass substrate using the photolithographic technique, and the working electrode was functionalized using RGO and monoclonal antibodies specific to the virus. These chips were integrated with polydimethylsiloxane microchannels. Structural and morphological characterizations were performed using X-ray photoelectron spectroscopy and scanning electron microscopy. Electrochemical studies revealed good selectivity and an enhanced detection limit of 0.5 PFU mL−1, where the chronoamperometric current increased linearly with H1N1 virus concentration within the range of 1 to 104 PFU mL−1 (R2 = 0.99). This microfluidic immunosensor can provide a promising platform for effective detection of biomolecules using minute samples.

1 February 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
JBJyoti Bhardwaj
Jyoti Bhardwaj
ASAbhinav Sharma
Abhinav Sharma
JJJaesung Jang
Jaesung Jang

1 August 2019 in Analytica Chimica Acta
Verified
Journal Article
Closed access
JBJyoti Bhardwaj
Jyoti Bhardwaj
NCNarendra Chaudhary
Narendra Chaudhary
HKHajin Kim
Hajin Kim
JJJaesung Jang
Jaesung Jang

1 October 2021 in Journal of Hazardous Materials
Verified
Journal Article
Open access
JBJyoti Bhardwaj
Jyoti Bhardwaj
SHSeongkyeol Hong
Seongkyeol Hong
JJJunbeom Jang
Junbeom Jang
CHChang-Ho Han
Chang-Ho Han
JLJaegil Lee
Jaegil Lee
JJJaesung Jang
Jaesung Jang
Air-transmissible pathogenic viruses, such as influenza viruses and coronaviruses, are some of the most fatal strains and spread rapidly by air, necessitating quick and stable measurements from sample air volumes to prevent further spread of diseases and to take appropriate steps rapidly. Measurements of airborne viruses generally require their collection into liquids or onto solid surfaces, with subsequent hydrosolization and then analysis using the growth method, nucleic-acid-based techniques, or immunoassays. Measurements can also be performed in real time without sampling, where species-specific determination is generally disabled. In this review, we introduce some recent advancements in the measurement of pathogenic airborne viruses. Air sampling and measurement technologies for viral aerosols are reviewed, with special focus on the effects of air sampling on damage to the sampled viruses and their measurements. Measurement of pathogenic airborne viruses is an interdisciplinary research area that requires understanding of both aerosol technology and biotechnology to effectively address the issues. Hence, this review is expected to provide some useful guidelines regarding appropriate air sampling and virus detection methods for particular applications.

1 March 2020 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
SJShalik R. Joshi
Shalik R. Joshi
ASAbhinav Sharma
Abhinav Sharma
GKGun-Ho Kim
Gun-Ho Kim
JJJaesung Jang
Jaesung Jang

11 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
SDSivaranjani Devarakonda
Sivaranjani Devarakonda
RSRenu Singh
Renu Singh
JBJyoti Bhardwaj
Jyoti Bhardwaj
JJJaesung Jang
Jaesung Jang
Although many studies concerning the detection of influenza virus have been published, a paper-based, label-free electrochemical immunosensor has never been reported. Here, we present a cost-effective, handmade paper-based immunosensor for label-free electrochemical detection of influenza virus H1N1. This immunosensor was prepared by modifying paper with a spray of hydrophobic silica nanoparticles, and using stencil-printed electrodes. We used a glass vaporizer to spray the hydrophobic silica nanoparticles onto the paper, rendering it super-hydrophobic. The super-hydrophobicity, which is essential for this paper-based biosensor, was achieved via 30–40 spray coatings, corresponding to a 0.39–0.41 mg cm−2 coating of nanoparticles on the paper and yielding a water contact angle of 150° ± 1°. Stencil-printed carbon electrodes modified with single-walled carbon nanotubes and chitosan were employed to increase the sensitivity of the sensor, and the antibodies were immobilized via glutaraldehyde cross-linking. Differential pulse voltammetry was used to assess the sensitivity of the sensors at various virus concentrations, ranging from 10 to 104 PFU mL−1, and the selectivity was assessed against MS2 bacteriophages and the influenza B viruses. These immunosensors showed good linear behaviors, improved detection times (30 min), and selectivity for the H1N1 virus with a limit of detection of 113 PFU mL−1, which is sufficiently sensitive for rapid on-site diagnosis. The simple and inexpensive methodologies developed in this study have great potential to be used for the development of a low-cost and disposable immunosensor for detection of pathogenic microorganisms, especially in developing countries.