Anika Steinert

Dr. Anika Steinert

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ASAnika Steinert
Anika Steinert
ISIgor Sattler
Igor Sattler
KOKaren Otte
Karen Otte
HRHanna Röhling
Hanna Röhling
SMSebastian Mansow-Model
Sebastian Mansow-Model
UMUrsula Müller-Werdan
Ursula Müller-Werdan
Various gait parameters can be used to assess the risk of falling in older adults. However, the state-of-the-art systems used to quantify gait parameters often come with high costs as well as training and space requirements. Gait analysis systems, which use mobile and commercially available cameras, can be an easily available, marker-free alternative. In a study with 44 participants (age ≥ 65 years), gait patterns were analyzed with three different systems: a pressure sensitive walkway system (GAITRite-System, GS) as gold standard, Motognosis Labs Software using a Microsoft Kinect Sensor (MKS), and a smartphone camera-based application (SCA). Intertrial repeatability showed moderate to excellent results for MKS (ICC(1,1) 0.574 to 0.962) for almost all measured gait parameters and moderate reliability in SCA measures for gait speed (ICC(1,1) 0.526 to 0.535). All gait parameters of MKS showed a high level of agreement with GS (ICC(2,k) 0.811 to 0.981). Gait parameters extracted with SCA showed poor reliability. The tested gait analysis systems based on different camera systems are currently only partially able to capture valid gait parameters. If the underlying algorithms are adapted and camera technology is advancing, it is conceivable that these comparatively simple methods could be used for gait analysis.

8 April 2017 in Universal Access in the Information Society
Verified
Journal Article
Closed access
PDF file
ASAnika Steinert
Anika Steinert
MHMarten Haesner
Marten Haesner
ESElisabeth Steinhagen-Thiessen
Elisabeth Steinhagen-Thiessen

10 January 2018 in Sport Sciences for Health
Verified
Journal Article
Closed access
PDF file
ASAnika Steinert
Anika Steinert
Ilona BuchemIlona Buchem
Ilona Buchem
AMAgathe Merceron
Agathe Merceron
JKJörn Kreutel
Jörn Kreutel
MHMarten Haesner
Marten Haesner

14 February 2020 in JMIR Aging
Verified
Journal Article
Open access
SRSophie Rabe
Sophie Rabe
AAArash Azhand
Arash Azhand
WPWolfgang Pommer
Wolfgang Pommer
SMSwantje Müller
Swantje Müller
ASAnika Steinert
Anika Steinert
Background: Fall-risk assessment is complex. Based on current scientific evidence, a multifactorial approach, including the analysis of physical performance, gait parameters, and both extrinsic and intrinsic risk factors, is highly recommended. A smartphone-based app was designed to assess the individual risk of falling with a score that combines multiple fall-risk factors into one comprehensive metric using the previously listed determinants. Objective: This study provides a descriptive evaluation of the designed fall-risk score as well as an analysis of the app’s discriminative ability based on real-world data. Methods: Anonymous data from 242 seniors was analyzed retrospectively. Data was collected between June 2018 and May 2019 using the fall-risk assessment app. First, we provided a descriptive statistical analysis of the underlying dataset. Subsequently, multiple learning models (Logistic Regression, Gaussian Naive Bayes, Gradient Boosting, Support Vector Classification, and Random Forest Regression) were trained on the dataset to obtain optimal decision boundaries. The receiver operating curve with its corresponding area under the curve (AUC) and sensitivity were the primary performance metrics utilized to assess the fall-risk score's ability to discriminate fallers from nonfallers. For the sake of completeness, specificity, precision, and overall accuracy were also provided for each model. Results: Out of 242 participants with a mean age of 84.6 years old (SD 6.7), 139 (57.4%) reported no previous falls (nonfaller), while 103 (42.5%) reported a previous fall (faller). The average fall risk was 29.5 points (SD 12.4). The performance metrics for the Logistic Regression Model were AUC=0.9, sensitivity=100%, specificity=52%, and accuracy=73%. The performance metrics for the Gaussian Naive Bayes Model were AUC=0.9, sensitivity=100%, specificity=52%, and accuracy=73%. The performance metrics for the Gradient Boosting Model were AUC=0.85, sensitivity=88%, specificity=62%, and accuracy=73%. The performance metrics for the Support Vector Classification Model were AUC=0.84, sensitivity=88%, specificity=67%, and accuracy=76%. The performance metrics for the Random Forest Model were AUC=0.84, sensitivity=88%, specificity=57%, and accuracy=70%. Conclusions: Descriptive statistics for the dataset were provided as comparison and reference values. The fall-risk score exhibited a high discriminative ability to distinguish fallers from nonfallers, irrespective of the learning model evaluated. The models had an average AUC of 0.86, an average sensitivity of 93%, and an average specificity of 58%. Average overall accuracy was 73%. Thus, the fall-risk app has the potential to support caretakers in easily conducting a valid fall-risk assessment. The fall-risk score’s prospective accuracy will be further validated in a prospective trial.

21 December 2020 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
OSOskar Stamm
Oskar Stamm
ASAnika Steinert
Anika Steinert
Background: Expensive optoelectronic systems, considered the gold standard, require a laboratory environment and the attachment of markers, and they are therefore rarely used in everyday clinical practice. Two-dimensional (2D) human pose estimations for clinical purposes allow kinematic analyses to be carried out via a camera-based smartphone app. Since clinical specialists highly depend on the validity of information, there is a need to evaluate the accuracy of 2D pose estimation apps. Objective: The aim of the study was to investigate the accuracy of the 2D pose estimation of a mobility analysis app (Lindera-v2), using the PanopticStudio Toolbox data set as a reference standard. The study aimed to assess the differences in joint angles obtained by 2D video information generated with the Lindera-v2 algorithm and the reference standard. The results can provide an important assessment of the adequacy of the app for clinical use. Methods: To evaluate the accuracy of the Lindera-v2 algorithm, 10 video sequences were analyzed. Accuracy was evaluated by assessing a total of 30,000 data pairs for each joint (10 joints in total), comparing the angle data obtained from the Lindera-v2 algorithm with those of the reference standard. The mean differences of the angles were calculated for each joint, and a comparison was made between the estimated values and the reference standard values. Furthermore, the mean absolute error (MAE), root mean square error, and symmetric mean absolute percentage error of the 2D angles were calculated. Agreement between the 2 measurement methods was calculated using the intraclass correlation coefficient (ICC[A,2]). A cross-correlation was calculated for the time series to verify whether there was a temporal shift in the data. Results: The mean difference of the Lindera-v2 data in the right hip was the closest to the reference standard, with a mean value difference of –0.05° (SD 6.06°). The greatest difference in comparison with the baseline was found in the neck, with a measurement of –3.07° (SD 6.43°). The MAE of the angle measurement closest to the baseline was observed in the pelvis (1.40°, SD 1.48°). In contrast, the largest MAE was observed in the right shoulder (6.48°, SD 8.43°). The medians of all acquired joints ranged in difference from 0.19° to 3.17° compared with the reference standard. The ICC values ranged from 0.951 (95% CI 0.914-0.969) in the neck to 0.997 (95% CI 0.997-0.997) in the left elbow joint. The cross-correlation showed that the Lindera-v2 algorithm had no temporal lag. Conclusions: The results of the study indicate that a 2D pose estimation by means of a smartphone app can have excellent agreement compared with a validated reference standard. An assessment of kinematic variables can be performed with the analyzed algorithm, showing only minimal deviations compared with data from a massive multiview system.

5 January 2024 in Zeitschrift für Gerontologie und Geriatrie
Verified
Journal Article
Open access
PDF file
NSNicole Strutz
Nicole Strutz
LPLuis Perotti
Luis Perotti
ASAnika Steinert
Anika Steinert
RKRobert Klebbe
Robert Klebbe
Background and objective: One possible approach to counter singularization and loneliness of older adults is the development and implementation of socially interactive robots. Little is known about the expectations and experiences of older adults with socially interactive humanoid robots. Material and methods: In a mixed-methods design study, user expectations before interaction and the experience and evaluation of verbal and non-verbal communication after interaction with a robot were assessed. Semi-structured interviews were conducted after the interaction. Results: The majority of older adults expected verbal communication. After the interaction the evaluation of the quality of verbal communication differed. Participants did not expect any form of nonverbal communication. Nonverbal communication was highlighted as particularly positive. Gestures, facial expressions, and body movements were described as confidence building. Conclusion: The robot’s ability to communicate nonverbally might positively influence older adults’ experience of communication with the robot. In the development of socially interactive robots non-verbal communication should be given more consideration in order to contribute to successful human-robot interaction.