C. Bor Fuh

Prof. Dr. C. Bor Fuh

Department of Applied Chemistry, National Chi Nan University, Nantou 545, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

15 August 2010 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
HTHweiyan Tsai
Hweiyan Tsai
JCJ.R. Chan
J.R. Chan
YLY.C. Li
Y.C. Li
FCF.C. Cheng
F.C. Cheng
CFC. Bor Fuh
C. Bor Fuh

21 August 2014 in The Analyst
Verified
Journal Article
Closed access
PDF file
SYS. F. Yang
S. F. Yang
BGB. Z. Gao
B. Z. Gao
HTHweiyan Tsai
Hweiyan Tsai
CFC. Bor Fuh
C. Bor Fuh
We report the preparation and application of biofunctional nanoparticles to detect C-reactive protein (CRP) in magnetic microplates. A CRP model biomarker was used to test the proposed detection method. Biofunctional magnetic nanoparticles, CRP, and biofunctional fluorescent nanoparticles were used in a sandwich nanoparticle immunoassay. The CRP concentrations in the samples were deduced from the reference plot, using the fluorescence intensity of the sandwich nanoparticle immunoassay. When biofunctional nanoparticles were used to detect CRP, the detection limit was 1.0 ng ml−1 and the linear range was between 1.18 ng ml−1 and 11.8 μg ml−1. The results revealed that the method involving biofunctional nanoparticles exhibited a lower detection limit and a wider linear range than those of the enzyme-linked immunosorbent assay (ELISA) and most other methods. For CRP measurements of serum samples, the differences between this method and ELISA in CRP measurements of serum samples were less than 13%. The proposed method can reduce the analysis time to one-third that of ELISA. This method demonstrates the potential to replace ELISA for rapidly detecting biomarkers with a low detection limit and a wide dynamic range.

1 December 1997 in Separation Science and Technology
Verified
Journal Article
Closed access
CFC. Bor Fuh
C. Bor Fuh
JGJ. C. Giddings
J. C. Giddings
Electric split-flow thin (SPLITT) fractionation permits the continuous separation of charged species, particularly proteins, at gram and subgram levels. We characterized this system and separated protein mixtures based on the difference between protein isoelectric points (pI). For characterization, we examined seven variables. Buffer stability was determined by measuring pH changes per hour and the UV spectrum before and after an electrical potential of 50 V was applied. The electrical field across the channel was determined by measuring the buffer conductivity and the current passed through it. The experimental and theoretical (calculated) fractional retrieval of proteins was determined by the relative magnitude of field-induced and outlet flow rates. The protein response at various electrical fields (0, 10, 20, 30 V) and solution pHs (4.85, 5.60, 6.87, and 7.80) was examined, as were the effects of the ionic strength of the buffer, protein recovery, and protein separation with pulsed sample injection. To separate protein mixtures after the system was characterized, we ran continuous SPLITT fractionation of five protein mixtures for more than 8 hours. Characterization results show that 1) buffer stability was good for acetate and phosphate buffers, 2) the electrical field across the channel was about 60% of that predicted by a geometric estimation, 3) experimental retrieval of four proteins (ferritin, BSA, hemoglobin, and cytochrome c) agreed well with calculated retrieval, 4) protein response at the four electrical fields and four solution pHs corresponded to the difference between protein pI and solution pH, 5) lower buffer ionic strength was better for protein separation, 6) protein sample recovery was reasonable from 78 to 90% (mean 85%) for six proteins, and 7) pulsed sample injection led to successful separation of five protein mixtures. In the second part of the study, three protein mixtures were successfully separated using continuous separation over 8 hours. The collected fractions showed clean separation as confirmed by flow field-flow fractionation and spectrophotometer analysis. The throughput was around 15 mg/h and the minimum difference between protein pIs that permitted separation was about two units. We conclude that isoelectric SPLITT fractionation has potential for use in protein purification.

16 July 2019 in Journal of the Chinese Chemical Society
Verified
Journal Article
Closed access
PDF file
HTHweiyan Tsai
Hweiyan Tsai
HHHsiao‐Ching Hu
Hsiao‐Ching Hu
CHChih‐Chung Hsieh
Chih‐Chung Hsieh
YLYi‐Hsuan Lu
Yi‐Hsuan Lu
CCChien‐Hong Chen
Chien‐Hong Chen
CFC. Bor Fuh
C. Bor Fuh

2 January 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
LRLingaraj Ryavanaki
Lingaraj Ryavanaki
HTHweiyan Tsai
Hweiyan Tsai
CFC. Bor Fuh
C. Bor Fuh
Novel bovine serum albumin (BSA)-gold nanoclusters with garlic extract modifications (mw_G-BSA-AuNCs) were prepared through microwave-assisted rapid synthesis. The modified nanoclusters were characterized and used for the simple and sensitive detection of Pb2+ ions. Both turn-on and turn-off methods were used and compared for Pb2+ ion detection. For Pb2+ ions, the preparation time for the modified nanoclusters was 10 min, and the detection time for the nanoclusters was 6 min. The modified nanoclusters were stable, and their fluorescence intensities changed by less than 10% in 60 days. The detection limit and linear range for the “off-on” method of mw_G-BSA-AuNCs for Pb2+ ion detection were 0.28 and 1–20 nM, respectively. The recoveries of the mw_G-BSA-AuNCs probe used for the detection of the Pb(II) ion in tap water ranged from 93.8% to 102.2%, with an average of 97.1%. The “off-on” method of mw_G-BSA-AuNCs can provide a lower detection limit, higher selectivity, and better recovery than the commonly used “turn-off” methods of mw_BSA-AuNCs for Pb2+ ion detection. The proposed method is superior to other methods proposed from 2018 to 2019 because it can provide a shorter preparation time and a lower detection limit with good selectivity. The microwave-assisted novel compound, mw_G-BSA-AuNCs, can be rapidly synthesized in a green manner and can provide a low detection limit, good selectivity, and a simple and fast reaction for Pb2+ ion detection.