Jean-Sébastien Boisvert

Dr. Jean-Sébastien Boisvert

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2021 in Cancers
Verified
Journal Article
Open access
PDF file
JLJulie Lafontaine
Julie Lafontaine
GCGuillaume B. Cardin
Guillaume B. Cardin
NMNicolas Malaquin
Nicolas Malaquin
JBJean-Sébastien Boisvert
Jean-Sébastien Boisvert
FRFrancis Rodier
Francis Rodier
PWPhilip Wong
Philip Wong
Radiotherapy (RT) is a key component of cancer treatment. Most of the time, radiation is given after surgery but for soft-tissue sarcomas (STS), pre-surgical radiation is commonly utilized. However, despite improvements in RT accuracy, the rate of local recurrence remains high and is the major cause of death for patients with STS. A better understanding of cell fates in response to RT could provide new therapeutic options to enhance tumour cell killing by RT and facilitate surgical resection. Here, we showed that irradiated STS cell cultures do not die but instead undergo therapy-induced senescence (TIS), which is characterized by proliferation arrest, senescence-associated β-galactosidase activity, secretion of inflammatory cytokines and persistent DNA damage. STS-TIS was also associated with increased levels of the anti-apoptotic Bcl-2 family of proteins which rendered cells targetable using senolytic Bcl-2 inhibitors. As oppose to radiation alone, the addition of senolytic agents Venetoclax (ABT-199) or Navitoclax (ABT-263) after irradiation induced a rapid apoptotic cell death in STS monolayer cultures and in a more complex three-dimensional culture model. Together, these data suggest a new promising therapeutic approach for sarcoma patients who receive neoadjuvant RT. The addition of senolytic agents to radiation treatments may significantly reduce tumour volume prior to surgery and thereby improve the clinical outcome of patients.

4 February 2020 in Cancers
Verified
Journal Article
Open access
PDF file
JLJulie Lafontaine
Julie Lafontaine
JBJean-Sébastien Boisvert
Jean-Sébastien Boisvert
AGAudrey Glory
Audrey Glory
SCSylvain Coulombe
Sylvain Coulombe
PWPhilip Wong
Philip Wong
Cancer therapy has evolved to a more targeted approach and often involves drug combinations to achieve better response rates. Non-thermal plasma (NTP), a technology rapidly expanding its application in the medical field, is a near room temperature ionized gas capable of producing reactive species, and can induce cancer cell death both in vitro and in vivo. Here, we used proliferation assay to characterize the plasma sensitivity of fourteen breast cancer cell lines. These assays showed that all tested cell lines were sensitive to NTP. In addition, a good correlation was found comparing cell sensitivity to NTP and radiation therapy (RT), where cells that were sensitive to RT were also sensitive to plasma. Moreover, in some breast cancer cell lines, NTP and RT have a synergistic effect. Adding a dose of PARP-inhibitor olaparib to NTP treatment always increases the efficacy of the treatment. Olaparib also exhibits a synergistic effect with NTP, especially in triple negative breast cancer cells. Results presented here help elucidate the position of plasma use as a potential breast cancer treatment.

1 March 2018 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
PDF file
JBJean-Sébastien Boisvert
Jean-Sébastien Boisvert
LSLuc Stafford
Luc Stafford
NNNicolas Naudé
Nicolas Naudé
JMJoelle Margot
Joelle Margot
FMFrancoise Massines
Francoise Massines
Diffuse dielectric barrier discharges are generated over a very wide range of frequencies. According to the targeted frequency, the glow, Townsend-like, hybrid, Ω and RF- α modes are sustained. In this paper, the electrical characterization of the discharge cell together with an electrical model are used to estimate the electron density from current and voltage measurements for excitation frequencies ranging from 50 kHz to 15 MHz. The electron density is found to vary from 10 14 to 10 17 m −3 over this frequency range. In addition, a collisional-radiative model coupled with optical emission spectroscopy is used to evaluate the electron temperature (assuming Maxwellian electron energy distribution function) in the same conditions. The time and space-averaged electron temperature is found to be about 0.3 eV in both the low-frequency and high-frequency ranges. However, in the medium-frequency range, it reaches almost twice this value as the discharge is in the hybrid mode. The hybrid mode is similar to the atmospheric-pressure glow discharge usually observed in helium DBDs at low frequency with the major difference being that the plasma is continuously sustained and is characterized by a higher power density.

10 February 2017 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
JBJean-Sébastien Boisvert
Jean-Sébastien Boisvert
JMJ Margot
J Margot
FMF Massines
F Massines
Recent studies have shown that tuning a dielectric barrier discharge (DBD) in the medium-frequency range (MF: from 0.3 to 3 MHz) allows a low-power and a high-power mode to be sustained. In the present article the effect of the driving frequency on a DBD is studied from the low-frequency range (LF: from 30 to 300 kHz) to the high-frequency range (HF: from 3 to 30 MHz). This is achieved using fast imaging together with electrical and spectroscopic diagnostics. At every frequency, a diffuse discharge is sustained. It is observed that at 25 kHz the discharge is an atmospheric-pressure glow discharge (APGD) while at 15 MHz the discharge behaves as a capacitive discharge in the RF- α mode. The usual LF APGD behavior is observed up to 100 kHz. Above 200 kHz, the positive column remains during the whole cycle so that the hybrid mode is sustained. At 5 MHz, the hybrid mode finally turns into the RF- α mode. In addition to the LF APGD, RF- α and hybrid modes obtained when the applied voltage is significantly higher than the ignition value, two other modes can be reached at low applied voltage. A Townsend-like mode is achieved from 50 to 100 kHz while in the medium-frequency range, the Ω mode is sustained. Moreover, only from 1.0 to 2.7 MHz there is a large hysteresis occurring when the discharge transits back and forth from the Ω to the hybrid mode. It is also found that when the frequency increases from 25 kHz to 15 MHz, the rms current increases over two orders of magnitudes while the rms voltage decreases by about 60%. The gas temperature estimated from N 2 rotational spectra is always close to room temperature but the discharge is more energy efficient (in the HF range) as a lower fraction of energy turns into gas heating.

26 January 2017 in Journal of Applied Physics
Verified
Journal Article
Closed access
JBJean-Sébastien Boisvert
Jean-Sébastien Boisvert
NSN. Sadeghi
N. Sadeghi
JMJ. Margot
J. Margot
FMF. Massines
F. Massines
Diffuse dielectric barrier discharges in atmospheric-pressure helium can be sustained over a wide range of excitation frequencies (from, but not restricted, 25 kHz to 15 MHz). The aim of the present paper is to identify the specific characteristics of the discharge modes that can be sustained in this frequency range, namely, the atmospheric-pressure Townsend-like discharge (APTD-L) mode, the atmospheric-pressure glow discharge (APGD) mode, the Ω mode, the hybrid mode, and the RF-α mode. This is achieved experimentally, by measuring the density of helium metastable atoms, which are known to play a driving role on the discharge kinetics. This density is measured by means of two absorption spectroscopy methods, one using a spectral lamp and the other one using a diode laser as a light source. The first one provides the time-averaged atom densities in the singlet He(21S) and triplet He(23S) metastable states, while with the second one we access the time-resolved density of He(23S) atoms. Time-averaged measurements indicate that the He(23S) density is relatively low in the APTD-L, the Ω and the RF-α modes (<4×1016 m−3 ) slightly higher in the APGD mode (2–7×1016 m−3 ), and still higher (>1×1017 m−3 ) in the hybrid mode. The hybrid mode is exclusively observed for frequencies from 0.2 to 3 MHz. However, time-resolved density measurement shows that at 1 MHz and below, the hybrid mode is not continuously sustained. Instead, the discharge oscillates between the Ω and the hybrid mode with a switching frequency about the kilohertz. This explains the significantly lower power required to sustain the plasma as compared to above 1 MHz.

18 July 2016 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
JBJean-Sébastien Boisvert
Jean-Sébastien Boisvert
JMJ Margot
J Margot
FMF Massines
F Massines
In this paper, we investigate DBDs in the medium frequency range (MF, 0.3–3 MHz). More precisely, for a 2 inter-dielectric gap in helium at atmospheric pressure, the frequency is varied from 1.0 to 2.7 MHz. The generated discharge shows similarities with both the low-frequency atmospheric-pressure glow discharge (APGD) and the atmospheric pressure capacitively coupled radio-frequency (CCRF) discharge. In the frequency range under investigation, two diffuse discharge modes can be observed depending on the voltage applied between the electrodes. At low applied voltage, the discharge emissions are barely visible and are concentrated in the center of the gas gap similarly to CCRF discharges in the mode where the electron density is concentrated in the bulk. Ohmic heating is the main power transfer mechanism. At higher applied voltage, the discharge emissions are 10 times more intense and are closer to the dielectric surfaces similarly to the more common radio-frequency α mode. These two discharge modes can be observed in the same experimental conditions with the amplitude of the applied voltage as sole control parameter. The gas temperature obtained from N2 impurities rotational spectrum increases from room temperature to about 500 K while the power density rises from 10−1 to 101 W cm−3 when the applied voltage is increased. In addition, when the discharge transits back and forth from the to the α mode, a hysteresis is observed. The transition from the to the α mode occurs abruptly with a large RMS current increase while the transition from the α to the mode is rather smooth with no significant discontinuity in the RMS current.