Inductor coils are integrated in many wearable garments for EM wave screening, heating and health monitoring. This paper presents a critical evaluation of the inductor characteristics of circular weft knitted coils for applications in etextiles. Inductors are knitted using circular needles with thin insulated metal wire and yarn knitted together. The resulting helical coils are characterized as a function of number of turns, coil diameter, needle size and insulated metal wire material. The results are compared to wound coils. Simulations of the knitted and wound coils show close agreement with the experimental results and confirm a higher inductance for the knits compared to the wound coils with the same pitch between turns. The parasitic coil capacitance is higher in the knit due to the vertical legs of the stitches, absent in wound coils. Knits with thin Cu and Litz wires result in flexible and wearable textile coils.
We demonstrate a novel low power inductive wearable plethysmography system. This consists of ultra-sensitive 3D knitted helical coils integrated in a garment and an oscillator circuit with high quality factor. The low power oscillator is built using two cross coupled FET pairs with low capacitance drawing only 95 μA during operation and with a response time smaller than 10 μs. The sensor system is linear, with negligible hysteresis. The best compromise in sensitivity and power consumption is obtained with a 3D knitted helical coil using jersey knit with elastic yarn, a lower knitting needle size than recommended for the yarn and minimizing both the number of stitches per winding as well as the stitches containing metal. A sensitivity of 2.7 kHz per mm change in circumference with a power consumption of 6.85 mW per 30 ms measurement time is reported. This system can be used for long term breathing monitoring using a garment indistinguishable from everyday clothing.
A wide range of signal quality indices (SQIs) related to statistical methods, are used to guide the optimisation process of knitted textile electrodes for ECG recordings. The electrode structure and composition as well as their integration into a garment are evaluated in view of a fully knitted garment. The dry electrodes with the best SQIs are obtained by using conductive yarn only with a compact knit structure and a medium level of roughness. The best SQIs for the e-garment were obtained by sewing electrodes at their edges only, into the knitted garment. This implementation outperforms the intarsia and double-knit method as it allows the garment some independent movement from the electrodes, reducing motion artifacts. Tests done on a healthy volunteer demonstrate excellent system performance under gentle ambulation. The advantage of using SQIs in the optimisation process of dry textile ECG electrodes is that they offer a quantitative benchmark against which to compare other approaches. The fully knitted clothing allows for more relaxed e-garments when gentle ambulation is considered.
21 September 2017 in Journal of Physics D: Applied Physics
Three TiO 2 deposition processes are used to coat the surface of Si nanowire array electrodes for electrochemical double layer capacitors in room temperature ionic liquid [Bmim][NTF 2 ]. The fabrication processes are based on wet chemistry only and temperature treatments are kept below 450 °C. Successful TiO 2 coatings are found to be those that are carried out at low pressure and with low TiO 2 coverage to avoid nanowires breakage. The best TiO 2 coated Si nanowire array electrode in [Bmim][NTF 2 ] showed energy densities of 0.9 Wh•kg-1 and power densities of 2.2 kW•kg-1 with a nanowire length of ~10 µm.
Reduction of drift in Complementary Metal Oxide-Semiconductor (CMOS) Ion-Sensitive Field-Effect Transistor (ISFET) pH sensors is demonstrated using monolayer and multilayer graphene sheets. Graphene blocks the ion penetration in the CMOS passivation layers and provides the physisorption sites needed for electrical double layer formation allowing sensing. With an in-house polymer-assisted graphene transfer (PAGT) process, monolayer and multilayer graphene sheets were manually transferred on top of the sensing membrane of CMOS ISFET sensors on a 2 by 4 mm chip. Experiments with pH buffers on five different chips were performed to extract the average performance parameters of capacitive attenuation, trapped charge, sensitivity, drift and noise. The stretched exponential function, that describes dispersion processes in amorphous solids such as silicon dioxide and silicon nitride, was modified to model the dynamic drift behaviour and analyse the effect of graphene on the performance of the sensors. The results show that on average the graphene coated ISFET sensors experience about 50% reduction in drift amplitude, up to 3 times slower surface modification and perform overall better compared to the plain unmodified devices.