The building and service sector accounts for nearly 40% of total energy use in Sweden. The existing, historic building stock accounts for large part of this energy use and comprises an important part of the national pursuit to increase energy efficiency. One main problem for decreasing energy use in the existing building stock is the lack of data describing thermal performance characteristics. This paper presents a novel development of the change-point model for predicting the thermal performance of buildings using selected time periods based on time-dependent variations in climate and user behavior. The predicted thermal power characteristics include total specific heat losses (Qtotal), energy use for hot water circulation (HWC) and hot tap water (HTW), and balance temperature. A residential district with 73 historic buildings in Linköping, Sweden, has been used as the study object. The developed model is shown to be effective and robust for describing building thermal performance. The average R2 was 0.70 for predictions of specific heat losses. The sensitivity analyses conclude that the selected time steps and months correspond to the highest R2 value. The average variation width for prediction of the balance temperature is 0.9 °C for buildings in the interquartile range based on a three-year comparison of hourly heating power supply data. Moreover, from a property owner perspective, the model is shown to be useful for identifying deviating thermal power characteristics and can easily be used to get an overview of a district.
The economic and environmental performance of a district heating (DH) system is to a great extent affected by the size and dynamic behavior of the DH load. By implementing energy efficiency measures (EEMs) to increase a building’s thermal performance and by performing cost-optimal energy renovation, the operation of the DH system will be altered. This study presents a systematic approach consisting of building categorization, life cycle cost (LCC) optimization, building energy simulation and energy system optimization procedures, investigating the profitability and environmental performance of cost-optimal energy renovation of a historic building district on the DH system. The results show that the proposed approach can successfully be used to predict the economic and environmental effects of cost-optimal energy renovation of a building district on the local DH system. The results revealed that the financial gains of the district are between 186 MSEK (23%) and 218 MSEK (27%) and the financial losses for the DH system vary between 117–194 MSEK (5–8%). However, the suggested renovation measures decrease the local and global CO2 emissions by 71–75 metric ton of CO2eq./year (4%) and 3545–3727 metric ton of CO2eq./year (41–43%), respectively. Total primary energy use was decreased from 57.2 GWh/year to 52.0–52.2 GWh/year.
Direct Air Capture (DAC) technologies have emerged as a promising solution to address climate change and meet global climate goals. However, despite the importance of DAC in designing carbon-negative buildings, there is a lack of research focusing on the energy and cost aspects in building ventilation systems. The objective of this research is to investigate the CO2 capture potential and economic viability of integrating small-scale DAC into a building ventilation system integrated within a gym space. A gym space located in the city of Linköping, Sweden, is used as the research object. Furthermore, the study investigates the CO2 capture potential across a portfolio of gym spaces corresponding to an area of 24,760 m2. The results show that the CO2 capture potential varies between 54 kg/day and 83 kg/day for the investigated gym space. Moreover, the total CO2 capture potential is between 588 ton CO2/year and 750 ton CO2/year for the portfolio of gym spaces. The results also demonstrate that regenerating the sorbent during non-operating hours is more energy-efficient and economically advantageous compared to performing four complete regeneration cycles during operating hours. Based on a sorbent capture potential of 0.2 mmol/g and 2.0 mmol/g, and a CO2 price of 1,000 SEK, the break-even price for energy is 0.25–0.53 SEK/kWh. Lastly, the research shows that, among the investigated cases, the only economically viable solution corresponds to sorbent capture potential 2.0 mmol/g and utilizing low-grade heat for the generation process, resulting in a total cost of 663 SEK/ton CO2.
In the era of society’s ongoing digitization and the exponential growth in data volume, alongside a growing energy demand, energy management plays an integral role in data centers (DCs) and is a key factor in the quest for decarbonization. In light of the complex nature of DCs, traditional energy management strategies are inadequate. This research introduces a data-driven decision-making framework for DCs, grounded in the OODA (Observation, Orientation, Decision, and Action) loop and based on insights from an Ericsson-operated DC in Linköping, Sweden. The developed framework enables DCs to enhance energy efficiency effectively. Rooted in the OODA loop and leveraging extensive datasets from DCs’ building management systems, this framework aids in decreasing cooling energy usage through strategic, data-driven decision-making. By adopting AI methods, specifically K-means clustering in this research, for continuous monitoring and fine-tuning (Proportional, Integral, Derivative) PID parameters, the framework aids in improving operational efficiency.
2 March 2023 in Advances in Building Energy Research
By identifying buildings with poor thermal performance and prioritizing these in terms of energy efficiency potential, a sustainable transformation of the building stock may be accelerated. However, there is currently a lack of thermal characteristics (TCs) differentiating total energy use from hot water circulation (HWC), hot tap water (HTW) and space heating in large building portfolios. This research demonstrates a methodology based on a change-point model for identifying and prioritizing TCs, which also enables prediction of the Comparative Energy Efficiency Potential (CEEP). The change-point model allows for the differentiation of various processes, i.e. space heating, HWC and HTW, using only heating supply data and outdoor temperature. The studied district consists of 70 multi-family buildings in the Vasastaden district in Linköping, Sweden. The findings demonstrate that the proposed methodology allows for identifying and prioritizing TCs connected to HWC, HTW and space heating. The highest CEEP is in space heating, corresponding to a maximum of 2,016 MWh (16% of the district’s energy use), followed by HWC, 699 MWh (6% of the district’s energy use) and HTW, 520 MWh (4% of the district’s energy use). Consequently, a total decrease of 3,235 MWh (26%) is made possible according to the studied energy efficiency targets.
Increased use of cogeneration in district heating (DH) systems is important in the pursuit towards a low-carbon society, particularly in light of the ongoing electrification across multiple sectors. Apart from reducing CO2 emissions, cogeneration also contributes to additional income for the DH system owner. Nonetheless, it is important to be aware that the economic and environmental performance of DH systems are directly connected to the energy use within DH networks. This research investigates sector interactions associated with the introduction of a biomass combined heat and power (CHP) and residential energy renovation according to (life cycle cost) LCC optimum and Swedish energy targets, with a focus on CO2 emissions and the system cost of the energy utility company. The study object consists of a DH system in Visby, Sweden, and 920 historic residential building undergoing energy renovation. The results show a profitability of 905–915 MSEK for the DH system with the integration of a CHP. Global CO2 emissions decrease by 32.6–33.1 ktonnes/year, 9.0–9.2 ktonnes/year, and 19.9–20.1 ktonnes/year, for marginal coal-condensing power (limited biofuel), natural gas combined cycle power (limited biofuel), and European average production, respectively. In addition, sensitivity analyses confirm the benefits of cogeneration related to both economics and CO2 emissions based on changes in key parameters of the DH system.