Scott Tyler

Dr. Scott Tyler

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2009 in Water Resources Research
Verified
Journal Article
Closed access
PDF file
STScott Tyler
Scott Tyler
JSJohn Selker
John Selker
MHMark B. Hausner
Mark B. Hausner
CHChristine E. Hatch
Christine E. Hatch
TTThomas Torgersen
Thomas Torgersen
SSS. Geoffrey Schladow
S. Geoffrey Schladow

21 November 2011 in Sensors
Verified
Journal Article
Open access
PDF file
MHMark Hausner
Mark Hausner
FSFrancisco Suárez
Francisco Suárez
KGKenneth E. Glander
Kenneth E. Glander
NGNick Van De Giesen
Nick Van De Giesen
JSJohn Selker
John Selker
STScott Tyler
Scott Tyler
Hydrologic research is a very demanding application of fiber-optic distributed temperature sensing (DTS) in terms of precision, accuracy and calibration. The physics behind the most frequently used DTS instruments are considered as they apply to four calibration methods for single-ended DTS installations. The new methods presented are more accurate than the instrument-calibrated data, achieving accuracies on the order of tenths of a degree root mean square error (RMSE) and mean bias. Effects of localized non-uniformities that violate the assumptions of single-ended calibration data are explored and quantified. Experimental design considerations such as selection of integration times or selection of the length of the reference sections are discussed, and the impacts of these considerations on calibrated temperatures are explored in two case studies.

27 April 2012 in Sensors
Verified
Journal Article
Open access
PDF file
NGNick Van De Giesen
Nick Van De Giesen
SSSusan Steele-Dunne
Susan Steele-Dunne
JJJop Jansen
Jop Jansen
OHOlivier Hoes
Olivier Hoes
MHMark Hausner
Mark Hausner
JSJohn Selker
John Selker
Over the past five years, Distributed Temperature Sensing (DTS) along fiber optic cables using Raman backscattering has become an important tool in the environmental sciences. Many environmental applications of DTS demand very accurate temperature measurements, with typical RMSE < 0.1 K. The aim of this paper is to describe and clarify the advantages and disadvantages of double-ended calibration to achieve such accuracy under field conditions. By measuring backscatter from both ends of the fiber optic cable, one can redress the effects of differential attenuation, as caused by bends, splices, and connectors. The methodological principles behind the double-ended calibration are presented, together with a set of practical considerations for field deployment. The results from a field experiment are presented, which show that with double-ended calibration good accuracies can be attained in the field.

1 January 2013 in Journal of Glaciology
Verified
Journal Article
Open access
PDF file
STScott Tyler
Scott Tyler
DHD.M. Holland
D.M. Holland
VZV. Zagorodnov
V. Zagorodnov
ASA.A. Stern
A.A. Stern
CSC. Sladek
C. Sladek
JBJ. Bryenton
J. Bryenton
Monitoring of ice-shelf and sub-ice-shelf ocean temperatures represents an important component in understanding ice-sheet stability. Continuous monitoring is challenging due to difficult surface access, difficulties in penetrating the ice shelf, and the need for long-term operation of non-recoverable sensors. We aim to develop rapid lightweight drilling and near-continuous fiber-optic temperature-monitoring methods to meet these challenges. During November 2011, two instrumented moorings were installed within and below the McMurdo Ice Shelf (a sub-region of the Ross Ice Shelf, Antarctica) at Windless Bight. We used a combination of ice coring for the upper portion of each shelf borehole and hot-point drilling for penetration into the ocean. The boreholes provided temporary access to the ice-shelf cavity, into which distributed temperature sensing (DTS) fiber-optic cables and conventional pressure/temperature transducers were installed. The DTS moorings provided near-continuous (in time and depth) observations of ice and ocean temperatures to a depth of almost 800 m beneath the ice-shelf surface. Data received document the presence of near-freezing water throughout the cavity from November through January, followed by an influx of warmer water reaching ∼150 m beneath the ice-shelf base during February and March. The observations demonstrate prospects for achieving much higher spatial sampling of temperature than more conventional oceanographic moorings.

16 November 2013 in Plant and Soil
Verified
Journal Article
Closed access
PDF file
JAJazmín E. Aravena
Jazmín E. Aravena
MBMarkus Berli
Markus Berli
SRSiul Ruiz
Siul Ruiz
FSFrancisco Suárez
Francisco Suárez
TGTeamrat Ghezzehei
Teamrat Ghezzehei
STScott Tyler
Scott Tyler

8 September 2014 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
SKScott Kobs
Scott Kobs
DHDavid M. Holland
David M. Holland
VZVictor Zagorodnov
Victor Zagorodnov
ASAlon Stern
Alon Stern
STScott Tyler
Scott Tyler
Measuring basal melting of ice shelves is challenging and represents a critical component toward understanding ocean-ice interactions and climate change. In November 2011, moorings containing fiber-optic cables for distributed temperature sensing (DTS) were installed through the McMurdo Ice Shelf, Antarctica, (~200 m) and extending ~600 m into the ice shelf cavity. The high spatial resolution of DTS allows for transient monitoring of the thermal gradient within the ice shelf. The gradient near the ice-ocean interface is extrapolated to the in situ freezing temperature in order to continuously track the ice-ocean interface. Seasonal melt rates are calculated to be ~1.0 mm d−1 and 8.6 mm d−1, and maximum melting corresponds to the arrival of seasonal warm surface water in the ice shelf cavity between January and April. The development of continuous, surface-based techniques for measuring basal melting represents a significant advance in monitoring ice shelf stability and ice-ocean interactions.