Pauline Dreesen

Ms. Pauline Dreesen

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2023 in Nature Medicine
Verified
Journal Article
Closed access
PDF file
MBMarie De Borre
Marie De Borre
HCHuiwen Che
Huiwen Che
QYQian Yu
Qian Yu
LLLore Lannoo
Lore Lannoo
KRKobe De Ridder
Kobe De Ridder
Bernard ThienpontBernard Thienpont
Bernard Thienpont

20 January 2020 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
TSTom Van Steenkiste
Tom Van Steenkiste
WGWillemijn Groenendaal
Willemijn Groenendaal
PDPauline Dreesen
Pauline Dreesen
SLSeulki Lee
Seulki Lee
SKSusie Klerkx
Susie Klerkx
TDTom Dhaene
Tom Dhaene
Sleep apnea is one of the most common sleep-related breathing disorders. It is diagnosed through an overnight sleep study in a specialized sleep clinic. This setup is expensive and the number of beds and staff are limited, leading to a long waiting time. To enable more patients to be tested, and repeated monitoring for diagnosed patients, portable sleep monitoring devices are being developed. These devices automatically detect sleep apnea events in one or more respiration-related signals. There are multiple methods to measure respiration, with varying levels of signal quality and comfort for the patient. In this study, the potential of using the bio-impedance (bioZ) of the chest as a respiratory surrogate is analyzed. A novel portable device is presented, combined with a two-phase Long Short-Term Memory (LSTM) deep learning algorithm for automated event detection. The setup is benchmarked using simultaneous recordings of the device and the traditional polysomnography in 25 patients. The results demonstrate that using only the bioZ, an area under the precision-recall curve of 46.9% can be achieved, which is on par with automatic scoring using a polysomnography respiration channel. The sensitivity, specificity and accuracy are 58.4%, 76.2% and 72.8% respectively. This confirms the potential of using the bioZ device and deep learning algorithm for automatically detecting sleep respiration events during the night, in a portable and comfortable setup.

1 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
WGWilfried Gyselaers
Wilfried Gyselaers
SVSharona Vonck
Sharona Vonck
ASAnneleen Simone Staelens
Anneleen Simone Staelens
DLDorien Lanssens
Dorien Lanssens
KTKathleen Tomsin
Kathleen Tomsin
LBLiesbeth Bruckers
Liesbeth Bruckers
To evaluate body water volumes and cardiac output in each trimester of pregnancies complicated with hypertension and/or poor fetal growth, relative to uncomplicated pregnancy. In this semi-longitudinal cohort study, a standardised non-invasive maternal hemodynamics assessment in first, second or third trimester was performed in 1068 women with uncomplicated pregnancy (UP), 75 with early onset (EPE) and 117 with late onset preeclampsia (LPE), 139 with gestational hypertension (GH), 129 with small for gestational age (SGA) neonates and 43 with essential hypertension (EH). Women with hypertension or SGA were included prior to onset of symptoms or at diagnosis of disease; 46% of women (758/1631) were assessed in ≥ 2 trimesters. Impedance cardiography and spectrum analysis were used to measure cardiac output, total body water (TBW), extracellular (ECW) and intracellular water (ICW). A linear mixed model was used for inter-trimestrial comparison of parity-, age- and BMI-corrected values within and between groups. For all pregnancies, TBW is higher in each consecutive trimester, mainly due to increasing fraction of ECW (ECW%). Compared to first trimester UP, ECW and ECW% are higher in EPE whereas TBW, ECW and ICW are lower in SGA. Compared to inter-trimestrial differences in UP, abnormal changes for body water volumes are observed in GH, EPE and LPE and for CO in EPE and LPE. Changes in EH are not different from UP. This study is the first to show that concomitant gestational changes of ECW and CO are different from UP already in preclinical stages of pregnancies complicated with hypertension and/or poor fetal growth, except EH. This finding highlights the relevance of early gestational assessment of maternal body fluid status in pregnancies at risk for hypertension or poor fetal growth.

5 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AYAhmed Youssef
Ahmed Youssef
FWFemke Wouters
Femke Wouters
JVJulie Vranken
Julie Vranken
PDPauline Dreesen
Pauline Dreesen
DBDianne de Korte-De Boer
Dianne de Korte-De Boer
Bart VanrumsteBart Vanrumste
Bart Vanrumste
This study introduces machine learning predictive models to predict the future values of the monitored vital signs of COVID-19 ICU patients. The main vital sign predictors include heart rate, respiration rate, and oxygen saturation. We investigated the performances of the developed predictive models by considering different approaches. The first predictive model was developed by considering the following vital signs: heart rate, blood pressure (systolic, diastolic and mean arterial, pulse pressure), respiration rate, and oxygen saturation. Similar to the first approach, the second model was developed using the same vital signs, but it was trained and tested based on a leave-one-subject-out approach. The third predictive model was developed by considering three vital signs: heart rate (HR), respiration rate (RR), and oxygen saturation (SpO2). The fourth model was a leave-one-subject-out model for the three vital signs. Finally, the fifth predictive model was developed based on the same three vital signs, but with a five-minute observation rate, in contrast with the aforementioned four models, where the observation rate was hourly to bi-hourly. For the five models, the predicted measurements were those of the three upcoming observations (on average, three hours ahead). Based on the obtained results, we observed that by limiting the number of vital sign predictors (i.e., three vital signs), the prediction performance was still acceptable, with the average mean absolute percentage error (MAPE) being 12%,5%, and 21.4% for heart rate, oxygen saturation, and respiration rate, respectively. Moreover, increasing the observation rate could enhance the prediction performance to be, on average, 8%,4.8%, and 17.8% for heart rate, oxygen saturation, and respiration rate, respectively. It is envisioned that such models could be integrated with monitoring systems that could, using a limited number of vital signs, predict the health conditions of COVID-19 ICU patients in real-time.

4 April 2018 in JMIR Cardio
Verified
Journal Article
Open access
CSChristophe Smeets
Christophe Smeets
VSValerie Storms
Valerie Storms
PVPieter M Vandervoort
Pieter M Vandervoort
PDPauline Dreesen
Pauline Dreesen
JVJulie Vranken
Julie Vranken
PDPaul Dendale
Paul Dendale
European Society of Cardiology guidelines for the treatment of heart failure (HF) prescribe uptitration of angiotensin-converting enzyme inhibitors (ACE-I) and β-blockers to the maximum-tolerated, evidence-based dose. Although HF prognosis can drastically improve when correctly implementing these guidelines, studies have shown that they are insufficiently implemented in clinical practice. The aim of this study was to verify whether supplementing the usual care with the CardioCoach follow-up tool is feasible and safe, and whether the tool is more efficient in implementing the guideline recommendations for β-blocker and ACE-I. A total of 25 HF patients were randomly assigned to either the usual care control group (n=10) or CardioCoach intervention group (n=15), and observed for 6 months. The CardioCoach follow-up tool is a two-way communication platform with decision support algorithms for semiautomatic remote medication uptitration. Remote monitoring sensors automatically transmit patient's blood pressure, heart rate, and weight on a daily basis. Patients' satisfaction and adherence for medication intake (10,018/10,825, 92.55%) and vital sign measurements (4504/4758, 94.66%) were excellent. However, the number of technical issues that arose was large, with 831 phone contacts (median 41, IQR 32-65) in total. The semiautomatic remote uptitration was safe, as there were no adverse events and no false positive uptitration proposals. Although no significant differences were found between both groups, a higher number of patients were on guideline-recommended medication dose in both groups compared with previous reports. The CardioCoach follow-up tool for remote uptitration is feasible and safe and was found to be efficient in facilitating information exchange between care providers, with high patient satisfaction and adherence. ClinicalTrials.gov NCT03294811; https://clinicaltrials.gov/ct2/show/NCT03294811 (Archived by WebCite at http://www.webcitation.org/6xLiWVsgM).

11 February 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PDPauline Dreesen
Pauline Dreesen
MSMelanie Schoutteten
Melanie Schoutteten
NVNele Vande Velde
Nele Vande Velde
IKIris Kaminski
Iris Kaminski
LHLine Heylen
Line Heylen
WGWilfried Gyselaers
Wilfried Gyselaers
Intra-abdominal hypertension (IAH) causes severe organ dysfunction. Our aim is to evaluate the effect of increased intra-abdominal pressure (IAP) on renal function, hypothesizing that venous congestion may increase proteinuria and fluid retention without endothelial dysfunction. Three urine samples were collected from 32 non-pregnant women undergoing laparoscopic-assisted vaginal hysterectomy (LAVH) and from 10 controls placed in Trendelenburg position for 60 min. Urine sampling was done before (PRE), during or immediately after (PER), and two hours after (POST) the procedure. Urinary albumin, protein and creatinine concentrations were measured in each sample, and ratios were calculated and compared within and between groups. During LAVH, the albumin/creatinine ratio (ACR) increased and persisted POST-procedure, which was not observed in controls. A positive correlation existed between the LAVH duration and the relative change in both ACR and protein/creatinine ratio (PCR) PER- and POST-procedure. Iatrogenic IAH increases urinary ACR and PCR in non-pregnant women via a process of venous congestion. This mechanism might explain the presentation of one specific subtype of late-onset preeclampsia, where no drop of maternal cardiac output is observed.