Andreas Lipphaus

Dr. Andreas Lipphaus

Clinic of Pediatric Surgery, University Hospitals of the Ruhr-University of Bochum, Bochum, North Rhine-Westphalia, Germany
+1
orcid
Physician, engineer & scientist

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in The Anatomical Record
Verified
Journal Article
Closed access
PDF file
Andreas LipphausAndreas Lipphaus
Andreas Lipphaus
UWUlrich Witzel
Ulrich Witzel

7 August 2021 in Materials
Verified
Journal Article
Open access
PDF file
Ana Rita PereiraAna Rita Pereira
Ana Rita Pereira
Andreas LipphausAndreas Lipphaus
Andreas Lipphaus
MEMert Ergin
Mert Ergin
SSSahar Salehi
Sahar Salehi
DGDominic Gehweiler
Dominic Gehweiler
MHMarietta Herrmann
Marietta Herrmann
In bone tissue engineering, the design of in vitro models able to recreate both the chemical composition, the structural architecture, and the overall mechanical environment of the native tissue is still often neglected. In this study, we apply a bioreactor system where human bone-marrow hMSCs are seeded in human femoral head-derived decellularized bone scaffolds and subjected to dynamic culture, i.e., shear stress induced by continuous cell culture medium perfusion at 1.7 mL/min flow rate and compressive stress by 10% uniaxial load at 1 Hz for 1 h per day. In silico modeling revealed that continuous medium flow generates a mean shear stress of 8.5 mPa sensed by hMSCs seeded on 3D bone scaffolds. Experimentally, both dynamic conditions improved cell repopulation within the scaffold and boosted ECM production compared with static controls. Early response of hMSCs to mechanical stimuli comprises evident cell shape changes and stronger integrin-mediated adhesion to the matrix. Stress-induced Col6 and SPP1 gene expression suggests an early hMSC commitment towards osteogenic lineage independent of Runx2 signaling. This study provides a foundation for exploring the early effects of external mechanical stimuli on hMSC behavior in a biologically meaningful in vitro environment, opening new opportunities to study bone development, remodeling, and pathologies.

31 October 2019 in The Anatomical Record
Verified
Journal Article
Open access
PDF file
AKAnna Krahl
Anna Krahl
Andreas LipphausAndreas Lipphaus
Andreas Lipphaus
MSMartin P. Sander
Martin P. Sander
FMFulvio Maffucci
Fulvio Maffucci
SHSandra Hochscheid
Sandra Hochscheid
UWUlrich Witzel
Ulrich Witzel
Adaptation of osteology and myology lead to the formation of hydrofoil foreflippers in Cheloniidae (all recent sea turtles except Dermochelys coriacea) which are used mainly for underwater flight. Recent research shows the biomechanical advantages of a complex system of agonistic and antagonistic tension chords that reduce bending stress in bones. Finite element structure analysis (FESA) of a cheloniid humerus is used to provide a better understanding of morphology and microanatomy and to link these with the main flipper function, underwater flight. Dissection of a Caretta caretta gave insights into lines of action, that is, the course that a muscle takes between its origin and insertion, of foreflipper musculature. Lines of action were determined by spanning physical threads on a skeleton of Chelonia mydas. The right humerus of this skeleton was micro‐CT scanned. Based on the scans, a finite element (FE) model was built and muscle force vectors were entered. Muscle forces were iteratively approximated until a uniform compressive stress distribution was attained. Two load cases, downstroke and upstroke, were computed. We found that muscle wrappings (m. coracobrachialis magnus and brevis, several extensors, humeral head of m. triceps) are crucial in addition to axial loading to obtain homogenous compressive loading in all bone cross‐sections. Detailed knowledge on muscle disposition leads to compressive stress distribution in the FE model which corresponds with the bone microstructure. The FE analysis of the cheloniid humerus shows that bone may be loaded mainly by compression if the bending moments are minimized.


10 April 2020 in The Anatomical Record
Verified
Journal Article
Open access
PDF file
Andreas LipphausAndreas Lipphaus
Andreas Lipphaus
UWUlrich Witzel
Ulrich Witzel
Bone and collagen fiber architecture adapt to external mechanical loads. In humans, due to the low insertion of the temporal muscle, mastication does not lead to a physiological loading of the calvaria. Forces applied to the skull by the dural folds can lead to compressive stresses in the calvaria. To investigate the relationship between mechanical loads and form in the skull and its membranes, in a finite element three‐dimensional model of the human skull, loads due to head acceleration in daily activities are applied to the falx cerebri and the tentorium cerebelli. The dural folds are modeled as membranes. The stress paths in the dural folds correlate with anatomical fiber direction. Head accelerations of 9 g lead to compressive stress in the calvaria. Finite element analysis of the falx cerebri and the tentorium cerebelli can be used to study the influence of mechanical stresses on the ossification of the dural folds and their impact on calvarial growth. This study presents an example of functional loading of bone by fibrous membranes and describes a possible mechanism by which Wolff's law works on the bone of the calvaria creating evolutionarily beneficial lightweight constructions.

5 November 2021 in Biomechanics
Verified
Journal Article
Open access
PDF file
Andreas LipphausAndreas Lipphaus
Andreas Lipphaus
MKMatthias Klimek
Matthias Klimek
UWUlrich Witzel
Ulrich Witzel
Open-book fractures are defined as the separation of the pubic symphysis or fractures of the rami and disruption of the anterior sacroiliac, sacrotuberous, and sacrospinal ligaments. They can be stabilized by fixation of the anterior arch. However, indications and advantages of additional placement of iliosacral screws remain unknown. A CT-based model of the healthy pelvis was created and ligaments were modeled as tension springs. Range of motion of the sacroiliac joint and the pubic symphysis, and bone and implant stresses were compared for the physiological model, anterior symphyseal plating alone, and additional posterior fixation using two iliosacral screws. The range of motion of the sacroiliac joint was reduced for anterior symphyseal plating alone and further decrease was noted with additional posterior fixation. Von Mises stresses acting on the symphyseal plate were 819.7 MPa for anterior fixation only and 711.56 MPa for additional posterior fixation equivalent with a safety factor of 1.1 and 1.26, respectively. Implant stresses were highest parasymphyseal. While bone stresses exhibited a more homogeneous distribution in the model of the healthy pelvis and the model with anterior and posterior fixation, pure symphyseal plating resulted in bending at the pelvic rami. The analysis does not indicate the superiority of either anterior plating alone or additional posterior fixation. In both cases, the physiological range of motion of the sacroiliac joint is permanently limited, which should be taken into account with regard to implant removal or more flexible techniques for stabilization of the sacroiliac joint.