Lyes DOUADJI

Prof. Lyes DOUADJI

Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XWXiaodong Wang
Xiaodong Wang
HCHui Chen
Hui Chen
MSMingquan Shi
Mingquan Shi
LDLyes DOUADJI
Lyes DOUADJI
The accurate calculation of inductance is the most basic problem of inductor design. Based on finite element method (FEM) analysis of the flux density distribution in the corner of the core, a local corner magnetic equivalent circuit (MEC) model is proposed for a core-type inductor. In this model, the corner is divided into three parallel branches, and the joint part of the corner and the core limb are divided into two branches, one of which is continuously divided into three branches. In addition, a flux leakage branch of the core window inner corner is modeled. These branches form a local corner MEC by series and parallel to describe the flux distribution of the corner. The calculation results show that, in the local corner MEC model, the core flux density distribution is consistent with the FEM simulation. The maximum relative error of the inductance is less than 6% and the average relative error is less than 4% compared to the physical prototype measured data with the range of current from 20 A to 1000 A, which shows that the local corner MEC model has a high accuracy inductance calculation.

27 July 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
KDKhouloud Djebbi
Khouloud Djebbi
YXYang Xiang
Yang Xiang
BSBiao Shi
Biao Shi
LDLyes DOUADJI
Lyes DOUADJI
XIAOHAN CHENXIAOHAN CHEN
XIAOHAN CHEN
DWDeqiang Wang
Deqiang Wang
The human Tau protein stands for one of the most conspicuous and crucial hallmarks of Alzheimer’s disease (AD) diagnosis, along with other tauopathies. However, the assay for direct detection of tiny Tau protein concentrations in human samples continues to pose a significant challenge for the early diagnosis of AD. Thus, an amplification-based strategy is required. In this proposed work, we established an impedimetric immunosensor to detect human Tau-441 protein in PBS buffer using a sandwich approach, wherein we employed two distinct monoclonal antibodies (HT7 and BT2) that specifically recognize the amino acids 159–198 of the target protein. Through this strategy, we were able to detect as low as 0.08 pg/mL. These findings were attributed to the use of a biotinylated antibody (BT2)-streptavidin complex, which facilitated the amplification of the normalized signal, resulting in a lower limit of detection in comparison to the directly based immunosensors. Subsequently, we investigated the designed immunosensor to assess the assay’s selectivity in the presence of different off-targets, and no cross-interaction was recorded. The outcomes of our study provide valuable new insights into the application of sandwich-based assay as a highly sensitive and selective immunosensor for the detection of small protein.