Sunsook Kim

Prof. Sunsook Kim

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2015 in Sustainability
Verified
Journal Article
Open access
PDF file
DPDuk Joon Park
Duk Joon Park
KYKihyung Yu
Kihyung Yu
YYYong Sang Yoon
Yong Sang Yoon
KKKee Han Kim
Kee Han Kim
Sunsook KimSunsook Kim
Sunsook Kim
The Korean government has established a national plan for the promotion of zero energy buildings to respond to climate change and energy crises. To achieve this plan, several energy efficiency policies for new and existing buildings have been developed. The Building Energy Efficiency Certification System (BEECS) aims to promote the spread of high energy-efficient buildings by evaluating and certifying building energy performance. This study discussed Korean building energy efficiency policies and analyzed especially the influence of the BEECS on the actual energy consumption of a residential building and calculated energy performance of non-residential buildings. The BEECS was evaluated to have influence on gas and district heating consumption in residential buildings. For non-residential buildings, a decreasing trend was shown in calculated primary energy consumption in the years since the BEECS has been enacted. Appropriate improvements of the certification system were also discussed by analyzing relationship between building characteristics and their energy consumptions.

10 May 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
HYHwang Yi
Hwang Yi
KMKim mijin
Kim mijin
YKYuri Kim
Yuri Kim
Sunsook KimSunsook Kim
Sunsook Kim
KLKyuin Lee
Kyuin Lee
Operation of environmentally responsive building components requires rapid prediction of the optimal adaptation of geometric shapes and positions, and such responsive configuration needs to be identified during the design process as early as possible. However, building simulation practices to characterize optimized shapes of various geometric design candidates are limited by complex simulation procedures, slow optimization, and lack of site information. This study suggests a practical approach to the design of responsive building façades by integrating on-site sensors, building performance simulation (BPS), machine-learning, and 3D geometry modeling on a unified design interface. To this end, a novel and efficient hybrid optimization algorithm, tabu-based adaptive pattern search simulated annealing (T-APSSA), was developed and integrated with wireless sensor data communication (using nRF24L01 and ESP8266 WiFi modules) on a parametric visual programming language (VPL) interface Rhino Grasshopper (0.9.0076, McNeel, Seattle, USA). The effectiveness of T-APSSA for early-stage BPS and optimal design is compared with other metaheuristic algorithms, and the proposed framework is validated by experimental optimal envelope (window shading) designs for single (daylight) and multiple (daylight and energy) objectives. Test results demonstrate the improved efficiency of T-APSSA in calculations (two to four times faster than other algorithms). This T-APSSA-integrated sensor-enabled design optimization practice supports rapid BPS and digital prototyping of responsive building façade design.

25 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
KCkyunghwa cho
kyunghwa cho
Sunsook KimSunsook Kim
Sunsook Kim
Existing buildings are likely to consume more energy and emit more greenhouse gases than new buildings because of inevitable deteriorations in physical performance. Accordingly, retrofitting of existing buildings is considered essential to reduce energy consumption and greenhouse gas emissions from the building sector. However, assessing the energy performance of existing buildings accurately has limitations because building materials undergo physical deterioration and the actual operational conditions differ from as-built documentation. There is also a difference in the level of data acquisition required for building energy performance assessment depending on the conditions of the building. The aim of this paper is to present types of methods for energy performance assessment of existing buildings considering this data acquisition level. We analyzed various assessment methods, which were classified into three prototypes of methods according to the required level of data acquisition. Type 1 assessed the target building based on literature sources. Type 2 conducted on-site audit and assessed the target building based on additional collected data. Type 3 assessed the target building by further estimating the building properties through analysis of the measured energy data. The applicability of the proposed methods were demonstrated using case studies of three buildings located in Seoul, South Korea.

20 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
HKHye Gi Kim
Hye Gi Kim
Sunsook KimSunsook Kim
Sunsook Kim
In an effort to improve the energy efficiency of existing buildings, it is necessary to first evaluate the energy performance of those buildings. Since it is difficult to obtain detailed information on existing buildings, the challenge is how to conduct reliable energy performance assessments with this limited information. As a result, many countries have adopted evaluation systems based on measured energy consumption data for existing buildings. This study aims to analyze the building energy consumption and characteristics using Korea’s national building database and provide an energy performance benchmark for continuous management of the energy performance of existing buildings. We analyzed the relationship between the basic statistical characteristics of the information collected from the national integrated energy database and energy consumption. The total floor area was found to be closely related to energy consumption, and various regression analysis methods were applied and compared to develop a benchmark to explain the trends of energy consumption according to the increase in total floor area. Finally, the developed benchmarks were used to evaluate energy consumption and examine the feasibility of the benchmarks.

14 December 2016 in Energies
Verified
Journal Article
Open access
PDF file
JOJi Hyun Oh
Ji Hyun Oh
HYHyun Jung Yoo
Hyun Jung Yoo
Sunsook KimSunsook Kim
Sunsook Kim
Recently, metal curtain wall systems have been widely used in high-rise buildings due to many advantages, including being lightweight, rapid construction, and aesthetic features. Since the metal frame may lead to lower energy performance, thermal discomfort, and condensation risk due to the high thermal conductivity, its thermal performance can be important for the improvement of the overall thermal performance of the curtain wall system, as well as the energy efficiency of the building envelope. This study aims to evaluate variety of design strategies to improve the thermal performance of steel curtain wall frames. Five base cases and three further steps were selected for two different head profile shapes based on a state-of-the art technology review, and their thermal transmittances were calculated through simulations according to the ISO 12631 standard which is an international standard for calculating thermal transmittance of curtain wall system. Measured results that were obtained from hot-box tests were compared with the calculated results to validate the simulation method of this study. The shape of the head profile did not strongly influence the overall thermal transmittance, and the choice of strategies for the rabbet space was more important. More effective strategies could be decided according to the steps for variation development. This result can serve as a guideline for the design of high-performance curtain wall frames.

21 December 2022 in Buildings
Verified
Journal Article
Open access
PDF file
HKHyegi Kim
Hyegi Kim
DJDawoon Jeong
Dawoon Jeong
SKSoon Jung Kwon
Soon Jung Kwon
Sunsook KimSunsook Kim
Sunsook Kim
The energy consumption of existing buildings depends on their physical features, climatic conditions, and business activities, such as operating hours and occupancy characteristics. It is necessary to perform a fair assessment of building energy performance considering the business activities. It has become especially necessary to collect and manage information on business activities in hospitals since hospitals operate continuously throughout the year, treating patients and using various medical equipment. This study aimed to develop a benchmark that considers business activities and to perform building energy performance assessments in hospitals using the developed benchmark. Initially, the necessary data from hospitals for assessing energy performance and developing an energy benchmark were identified. Then, survey items regarding the business activities and energy consumption of buildings were designed, and a survey was conducted at 48 general hospitals. Secondly, multiple linear regression was used to identify and normalize the major business activities affecting energy use and to develop a benchmark for energy performance assessment. Thereafter, the Energy Efficiency Ratio (EER), the result of comparing the actual energy consumption with the benchmark, was used as an index for the energy performance assessment. Thirdly, additional general hospitals were surveyed to validate the benchmark. The EER of the additional surveyed hospitals was calculated with the developed benchmark. The Energy Use Intensity (EUI) and EER of buildings were reviewed, and analysis was performed to identify why some buildings had a similar EUI but a different EER. Finally, a method to improve the benchmark is presented, and the improved benchmark model is compared with the existing model.