Keisuke Sugahara

Dr. Keisuke Sugahara

Department of Oral Pathobiological Science and Surgery, Tokyo Dental College, 2-9-18, Kandamisaki-Cho, Chiyoda-Ku, Tokyo 101-0061, Japan
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in International Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Open access
MKMasahide Koyachi
Masahide Koyachi
Keisuke SugaharaKeisuke Sugahara
Keisuke Sugahara
Kento OdakaKento Odaka
Kento Odaka
Satoru MatsunagaSatoru Matsunaga
Satoru Matsunaga
SAShinichi Abe
Shinichi Abe
AKA. Katakura
A. Katakura
The aim of this study was to verify the reproducibility and accuracy of preoperative planning in maxilla repositioning surgery performed with the use of computer-aided design/manufacturing technologies and mixed reality surgical navigation, using new registration markers and the HoloLens headset. Eighteen patients with a mean age of 26.0 years were included. Postoperative evaluations were conducted by comparing the preoperative virtual operation three-dimensional image (Tv) with the 1-month postoperative computed tomography image (T1). The three-dimensional surface analysis errors ranged from 79.9% to 97.1%, with an average error of 90.3%. In the point-based analysis, the errors at each point on the XYZ axes were calculated for Tv and T1 in all cases. The median signed value deviation of all calculated points on the XYZ axes was -0.03mm (range -2.93mm to 3.93mm). The median absolute value deviation of all calculated points on the XYZ axes was 0.38mm (range 0mm to 3.93mm). There were no statistically significant differences between any of the points on any of the axes. These values indicate that the method used was able to reproduce the maxilla position with high accuracy.

1 May 2021 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
Keisuke SugaharaKeisuke Sugahara
Keisuke Sugahara
MKMasahide Koyachi
Masahide Koyachi
YKYu Koyama
Yu Koyama
MSMaki Sugimoto
Maki Sugimoto
SMSatoru Matsunaga
Satoru Matsunaga
AKAkira Katakura
Akira Katakura
In the field of oral and maxillofacial surgery, many institutions have recently begun using three-dimensional printers to create three-dimensional models and mixed reality in a variety of diseases. Here, we report the actual situation model which we made using three-dimensional printer from virtual operation data and the resection that was performed while grasping a maxillary benign tumor and neighboring three-dimensional structure by designing an application for Microsoft® HoloLens, and using Mixed Reality surgery support during the procedure.

5 January 2023 in Maxillofacial Plastic and Reconstructive Surgery
Verified
Journal Article
Open access
PDF file
YKYu Koyama
Yu Koyama
Keisuke SugaharaKeisuke Sugahara
Keisuke Sugahara
MKMasahide Koyachi
Masahide Koyachi
KTKotaro Tachizawa
Kotaro Tachizawa
AIAkira Iwasaki
Akira Iwasaki
AKAkira Katakura
Akira Katakura
Background: Mesiodentes are the most common supernumerary teeth. The cause is not fully understood, although proliferations of genetic factors and the dental lamina have been implicated. Mesiodentes can cause delayed or ectopic eruption of permanent incisors, which can further alter occlusion and appearance. Careful attention should be paid to the position and direction of the mesiodentes because of possible damage to adjacent roots in the permanent dentition period, errant extraction in the deciduous and mixed dentition periods, and damage to the permanent tooth embryo. To avoid these complications, we applied mixed reality (MR) technology using the HoloLens® (Microsoft, California). In this study, we report on three cases of mesiodentes extraction under general anesthesia using MR technology. Results: The patients ranged in age from 6 to 11 years, all three were boys, and the direction of eruption was inverted in all cases. The extraction approach was palatal in two cases and labial in one case. The average operative time was 32 min, and bleeding was minimal in all cases. No intraoperative or postoperative complications occurred. An image was shared preoperatively with all the surgeons using an actual situation model. Three surgeons used Microsoft HoloLens® during surgery, shared MR, and operated while superimposing the application image in the surgical field. Conclusions: The procedure was performed safely; further development of MR surgery support systems in the future is suggested.

5 March 2018 in Maxillofacial Plastic and Reconstructive Surgery
Verified
Journal Article
Open access
PDF file
Keisuke SugaharaKeisuke Sugahara
Keisuke Sugahara
YKYoshiharu Katsumi
Yoshiharu Katsumi
MKMasahide Koyachi
Masahide Koyachi
YKYu Koyama
Yu Koyama
SMSatoru Matsunaga
Satoru Matsunaga
AKAkira Katakura
Akira Katakura
Along with the advances in technology of three-dimensional (3D) printer, it became a possible to make more precise patient-specific 3D model in the various fields including oral and maxillofacial surgery. When creating 3D models of the mandible and maxilla, it is easier to make a single unit with a fused temporomandibular joint, though this results in poor operability of the model. However, while models created with a separate mandible and maxilla have operability, it can be difficult to fully restore the position of the condylar after simulation. The purpose of this study is to introduce and asses the novel condylar repositioning method in 3D model preoperational simulation. Our novel condylar repositioning method is simple to apply two irregularities in 3D models. Three oral surgeons measured and evaluated one linear distance and two angles in 3D models. This study included two patients who underwent sagittal split ramus osteotomy (SSRO) and two benign tumor patients who underwent segmental mandibulectomy and immediate reconstruction. For each SSRO case, the mandibular condyles were designed to be convex and the glenoid cavities were designed to be concave. For the benign tumor cases, the margins on the resection side, including the joint portions, were designed to be convex, and the resection margin was designed to be concave. The distance from the mandibular ramus to the tip of the maxillary canine, the angle created by joining the inferior edge of the orbit to the tip of the maxillary canine and the ramus, the angle created by the lines from the base of the mentum to the endpoint of the condyle, and the angle between the most lateral point of the condyle and the most medial point of the condyle were measured before and after simulations. Near-complete matches were observed for all items measured before and after model simulations of surgery in all jaw deformity and reconstruction cases. We demonstrated that 3D models manufactured using our method can be applied to simulations and fully restore the position of the condyle without the need for special devices.

1 June 2023 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
MKMasahide Koyachi
Masahide Koyachi
Keisuke SugaharaKeisuke Sugahara
Keisuke Sugahara
KTKotaro Tachizawa
Kotaro Tachizawa
ANAkihiro Nishiyama
Akihiro Nishiyama
Kento OdakaKento Odaka
Kento Odaka
AKAkira Katakura
Akira Katakura
Image in Medicine and Surgery Mixed-reality and computer-aided design/computer-aided manufacturing technology for mandibular reconstruction: a case description Masahide Koyachi, Keisuke Sugahara, Kotaro Tachizawa, Akihiro Nishiyama, Kento Odaka, Satoru Matsunaga, Maki Sugimoto, Akira Katakura

11 September 2020 in Maxillofacial Plastic and Reconstructive Surgery
Verified
Journal Article
Open access
PDF file
Keisuke SugaharaKeisuke Sugahara
Keisuke Sugahara
MKMasahide Koyachi
Masahide Koyachi
Kento OdakaKento Odaka
Kento Odaka
SMSatoru Matsunaga
Satoru Matsunaga
AKAkira Katakura
Akira Katakura
Background: Le Fort I osteotomy is a highly effective treatment for skeletal jaw deformities and is commonly performed. High Le Fort I osteotomy is a modified surgical procedure performed for improving the depression of the cheeks by setting the osteotomy higher than the conventional Le Fort I osteotomy. Developments in three-dimensional (3D) technology have popularized the use of 3D printers in various institutions, especially in orthognathic surgeries. In this study, we report a safe and inexpensive method of performing a high Le Fort I osteotomy using a novel 3D device and piezosurgery, which prevent tooth root injury without disturbing the operation field for patients with a short midface and long tooth roots. Results: A 17-year-old woman presented with facial asymmetry, mandibular protrusion, a short midface, and long tooth roots. We planned high Le Fort I osteotomy and bilateral sagittal split ramus osteotomy. Prevention of damage to the roots of the teeth and the infraorbital nerve and accurate determination of the posterior osteotomy line were crucial for clinical success. Le Fort I osteotomy using 3D devices has been reported previously but were particularly large in size for this case. Additionally, setting the fixing screw of the device was difficult, because of the risk of damage to the roots of the teeth. Therefore, a different surgical technique, other than the conventional Le Fort I osteotomy and 3D device, was required. The left and right parts of the 3D device were fabricated separately, to prevent any interference in the surgical field. Further, the 3D device was designed to accurately cover the bone surface from the piriform aperture to the infra-zygomatic crest with two fixation points (the anterior nasal spine and the piriform aperture), which ensured stabilization of the 3D device. The device is thin and does not interfere with the surgical field. Safe and accurate surgical performance is possible using this device and piezosurgery. The roots of the teeth and the infraorbital nerve were unharmed during the surgery. Conclusions: This device is considerably smaller than conventional devices and is a simple, low-cost, and efficient method for performing accurate high Le Fort I osteotomy.