Sören Backhaus

Dr. Sören Backhaus


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Radiology
Verified
Journal Article
Closed access
ASAndreas Schuster
Andreas Schuster
SBSören Backhaus
Sören Backhaus
TSThomas Stiermaier
Thomas Stiermaier
JNJenny-Lou Navarra
Jenny-Lou Navarra
JUJohannes Uhlig
Johannes Uhlig
IEIngo Eitel
Ingo Eitel
Atrial function provided incremental prognostic value for major adverse cardiovascular event prediction beyond established clinical and cardiac MRI parameters, including ventricular function and in... Background The role of left atrial (LA) performance in acute myocardial infarction (AMI) remains controversial. Cardiac MRI myocardial feature tracking (hereafter, MRI-FT) is a method used to quant...

1 March 2021 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
SBSören Backhaus
Sören Backhaus
GMGeorg Metschies
Georg Metschies
MBMarcus Billing
Marcus Billing
JSJonas Schmidt-Rimpler
Jonas Schmidt-Rimpler
JKJohannes T. Kowallick
Johannes T. Kowallick
ASAndreas Schuster
Andreas Schuster
Myocardial deformation analyses using cardiovascular magnetic resonance (CMR) feature tracking (CMR-FT) have incremental value in the assessment of cardiac function beyond volumetric analyses. Since guidelines do not recommend specific imaging parameters, we aimed to define optimal spatial and temporal resolutions for CMR cine images to enable reliable post-processing. Intra- and inter-observer reproducibility was assessed in 12 healthy subjects and 9 heart failure (HF) patients. Cine images were acquired with different temporal (20, 30, 40 and 50 frames/cardiac cycle) and spatial resolutions (high in-plane 1.5 × 1.5 mm through-plane 5 mm, standard 1.8 × 1.8 x 8mm and low 3.0 × 3.0 x 10mm). CMR-FT comprised left ventricular (LV) global and segmental longitudinal/circumferential strain (GLS/GCS) and associated systolic strain rates (SR), and right ventricular (RV) GLS. Temporal but not spatial resolution did impact absolute strain and SR. Maximum absolute changes between lowest and highest temporal resolution were as follows: 1.8% and 0.3%/s for LV GLS and SR, 2.5% and 0.6%/s for GCS and SR as well as 1.4% for RV GLS. Changes of strain values occurred comparing 20 and 30 frames/cardiac cycle including LV and RV GLS and GCS (p < 0.001–0.046). In contrast, SR values (LV GLS/GCS SR) changed significantly comparing all successive temporal resolutions (p < 0.001–0.013). LV strain and SR reproducibility was not affected by either temporal or spatial resolution, whilst RV strain variability decreased with augmentation of temporal resolution. Temporal but not spatial resolution significantly affects strain and SR in CMR-FT deformation analyses. Strain analyses require lower temporal resolution and 30 frames/cardiac cycle offer consistent strain assessments, whilst SR measurements gain from further increases in temporal resolution.

1 January 2019 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
SBSören Backhaus
Sören Backhaus
WSWieland Staab
Wieland Staab
MSMichael Steinmetz
Michael Steinmetz
CRChristian O. Ritter
Christian O. Ritter
JLJoachim Lotz
Joachim Lotz
JKJohannes T. Kowallick
Johannes T. Kowallick
Cardiovascular magnetic resonance (CMR) represents the clinical gold standard for the assessment of biventricular morphology and function. Since manual post-processing is time-consuming and prone to observer variability, efforts have been directed towards automated volumetric quantification. In this study, we sought to validate the accuracy of a novel approach providing fully automated quantification of biventricular volumes and function in a “real-world” clinical setting. Three-hundred CMR examinations were randomly selected from the local data base. Fully automated quantification of left ventricular (LV) mass, LV and right ventricular (RV) end-diastolic and end-systolic volumes (EDV/ESV), stroke volume (SV) and ejection fraction (EF) were performed overnight using commercially available software (suiteHEART®, Neosoft, Pewaukee, Wisconsin, USA). Parameters were compared to manual assessments (QMass®, Medis Medical Imaging Systems, Leiden, Netherlands). Sub-group analyses were further performed according to image quality, scanner field strength, the presence of implanted aortic valves and repaired Tetralogy of Fallot (ToF). Biventricular automated segmentation was feasible in all 300 cases. Overall agreement between fully automated and manually derived LV parameters was good (LV-EF: intra-class correlation coefficient [ICC] 0.95; bias − 2.5% [SD 5.9%]), whilst RV agreement was lower (RV-EF: ICC 0.72; bias 5.8% [SD 9.6%]). Lowest agreement was observed in case of severely altered anatomy, e.g. marked RV dilation but normal LV dimensions in repaired ToF (LV parameters ICC 0.73–0.91; RV parameters ICC 0.41–0.94) and/or reduced image quality (LV parameters ICC 0.86–0.95; RV parameters ICC 0.56–0.91), which was more common on 3.0 T than on 1.5 T. Fully automated assessments of biventricular morphology and function is robust and accurate in a clinical routine setting with good image quality and can be performed without any user interaction. However, in case of demanding anatomy (e.g. repaired ToF, severe LV hypertrophy) or reduced image quality, quality check and manual re-contouring are still required.

27 August 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
SBSören Backhaus
Sören Backhaus
GMGeorg Metschies
Georg Metschies
VZVictoria Zieschang
Victoria Zieschang
JEJennifer Erley
Jennifer Erley
SZSeyedeh Mahsa Zamani
Seyedeh Mahsa Zamani
ASAndreas Schuster
Andreas Schuster

12 January 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ASAndreas Schuster
Andreas Schuster
SBSören Backhaus
Sören Backhaus
TSThomas Stiermaier
Thomas Stiermaier
JNJenny-Lou Navarra
Jenny-Lou Navarra
JUJohannes Uhlig
Johannes Uhlig
IEIngo Eitel
Ingo Eitel
Background: Right ventricular (RV) function is a known predictor of adverse events in heart failure and following acute myocardial infarction (AMI). While right atrial (RA) involvement is well characterized in pulmonary arterial hypertension, its relative contributions to adverse events following AMI especially in patients with heart failure and congestion need further evaluation. Methods: In this cardiovascular magnetic resonance (CMR)-substudy of AIDA STEMI and TATORT NSTEMI, 1235 AMI patients underwent CMR after primary percutaneous coronary intervention (PCI) in 15 centers across Germany (n = 795 with ST-elevation myocardial infarction and 440 with non-ST-elevation MI). Right atrial (RA) performance was evaluated using CMR myocardial feature tracking (CMR-FT) for the assessment of RA reservoir (total strain εs), conduit (passive strain εe), booster pump function (active strain εa), and associated strain rates (SR) in a blinded core-laboratory. The primary endpoint was the occurrence of major adverse cardiac events (MACE) 12 months post AMI. Results: RA reservoir (εs p = 0.061, SRs p = 0.049) and conduit functions (εe p = 0.006, SRe p = 0.030) were impaired in patients with MACE as opposed to RA booster pump (εa p = 0.579, SRa p = 0.118) and RA volume index (p = 0.866). RA conduit function was associated with the clinical onset of heart failure and MACE independently of RV systolic function and atrial fibrillation (AF) (multivariable analysis hazard ratio 0.95, 95% confidence interval 0.92 to 0.99, p = 0.009), while RV systolic function and AF were not independent prognosticators. Furthermore, RA conduit strain identified low- and high-risk groups within patients with reduced RV systolic function (p = 0.019 on log rank testing). Conclusions: RA impairment is a distinct feature and independent risk factor in patients following AMI and can be easily assessed using CMR-FT-derived quantification of RA strain.

1 May 2023 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
SBSören Backhaus
Sören Backhaus
TLTorben Lange
Torben Lange
ASAlexander Schulz
Alexander Schulz
RERuben Evertz
Ruben Evertz
SFSimon Frey
Simon Frey
ASAndreas Schuster
Andreas Schuster
Evaluation of the left atrioventricular coupling index (LACI) in a rest and exercise-stress cardiovascular magnetic resonance imaging protocol allows identification of patients with heart failure and preserved ejection fraction with high diagnostic accuracy. LACI holds similar diagnostic accuracy at rest compared with left atrial ejection fraction during exercise stress. This highlights the value of LACI as a widely available and cost-effective test for diastolic dysfunction, which may help to guide patient selection for referral to specialized testing/treatment.