Ali Shakeri Kahnamouei

Mr. Ali Shakeri Kahnamouei


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2021 in IEEE Systems Journal
Verified
Journal Article
Closed access
AKAli Shakeri Kahnamouei
Ali Shakeri Kahnamouei
SLSaeed Lotfifard
Saeed Lotfifard
In case of high-impact low-probability events, in order to restore the critical loads of the distribution network as much as possible, it is necessary to employ all available resources such as microgrids and distributed generations. This article presents a two-stage method for critical load restoration after an extreme event utilizing the coordination of all available distributed generations, microgrids, and demand response programs. In the first stage, the postdisaster reconfiguration of the network is determined, and in the second stage, the demand response outputs of the responsive loads and the restoration status of all critical loads are ascertained. In the first stage, an algorithm is proposed to determine electrical islands, and in the second stage, a new model based on the generalized Benders decomposition algorithm is proposed, which considers demand response programs and all operational constraints and aims to maximize the restored critical loads. The effectiveness of the proposed method is verified by simulating the 33- and 69-bus test systems.

20 June 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
AKAli Shakeri Kahnamouei
Ali Shakeri Kahnamouei
SLSaeed Lotfifard
Saeed Lotfifard
This article proposes a fault location identification method for radial power distribution systems with inverter-interfaced distributed generations (IIDGs). The proposed method is not restricted to any specific types of data. It can fully utilize all available data types in power distribution systems to enhance the accuracy of results. The dataset may include synchronized voltage and current measurements collected by micro-phasor measurement units (micro-PMUs) and/or unsynchronized measurements collected by legacy measuring devices, active and reactive power measurements, pseudo measurements of load values, and virtual measurements based on Kirchhoff's laws. The proposed method explicitly considers uncertainties in the dataset and is applicable to different load types. The article proposes a mathematical model for representing IIDGs in fault location identification applications that does not require any synchronized sampled data or during the fault period data collection. Simulation results on IEEE 34-node feeder demonstrate the accuracy of the proposed method.

1 January 2017
Verified
Conference Paper
Closed access
AKAli Shakeri Kahnamouei
Ali Shakeri Kahnamouei
TBT.G. Bolandi
T.G. Bolandi
MHM.-R. Haghifam
M.-R. Haghifam
The resilience assessment of complex and large-scale systems such as electrical power systems has becoming an inseparable part in analysing the reliable performance of the systems in the presence of high-impact, low-probability (HILP) incidents, such as extreme natural disasters. Considering the application of the resilience in various domains, the different definitions can be found for assessment of resilience in one system and several approaches can be applied to measure it. The necessity of increasing the resilience of power system infrastructures in response to HILP disasters for supplying at least emergency loads when facing unexpected and catastrophic events has becoming more and more clear. Reliability evaluation of power systems provides the likely behaviour of a system in normal condition but fails to model the high order contingencies which have low probabilities of occurrence. However, withstanding, absorbing and rapidly recovering from HILP events still remains a significant challenge which can be analysed in resilience assessment. This paper presents a conceptual framework of resilience domains and its measurement approaches, especially a thorough conceptual framework of resilience as a subcategory of vulnerability in electrical power systems. The conceptual difference between resilience and other indices of power system assessment such as reliability, risk and security are also presented in this research.

17 February 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
AKAli Shakeri Kahnamouei
Ali Shakeri Kahnamouei
SLSaeed Lotfifard
Saeed Lotfifard
MRMohammadali Rostami
Mohammadali Rostami
This paper presents a method for the optimized reconfiguration of radial distribution systems that explicitly considers the protection systems constraints. A fully automated method based on graph analysis is proposed to automatically identify the primary-backup relation between each pair of protection devices in different network topologies. Accordingly, protection systems constraints are derived automatically and incorporated into the optimization problem. The linearized and convexified nonlinear power flow equations, along with protection system coordination constraints, are solved using the second-order cone programming (SOCP) that assures the feasibility of the results while accelerating the convergence rate. The effectiveness of the proposed methodology is demonstrated through the simulation of the 33-node IEEE test system.

7 February 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
AKAli Shakeri Kahnamouei
Ali Shakeri Kahnamouei
SLSaeed Lotfifard
Saeed Lotfifard
This paper proposes a method for identifying fault locations in active distribution networks equipped with inverter-interfaced distributed generations (IIDGs). The proposed method is capable of utilizing all available mixed datasets of modern distribution networks to improve the performance and precision of the fault location identification results. The dataset may include analog/oscillography data and discrete/status data. A causal model for the faulted system based on probabilistic Petri-Nets and backward reachability analysis is developed that utilizes the collected discrete/status data to determine the faulted section of the system. The model accounts for possible failures of protective devices and false notifications from fault indicators. An enhanced impedance-based fault location identification method is proposed that utilizes analog data from micro-PMUs and/or legacy measuring devices to estimate the exact location of the fault within the identified faulted section. It explicitly accounts for the uncertainties in the collected data. The proposed method's performance is showcased by simulating the IEEE 34-node distribution test system.

21 October 2025 in arXiv
Verified
Preprint
Open access
PDF file
AKAli Shakeri Kahnamouei
Ali Shakeri Kahnamouei
SLSaeed Lotfifard
Saeed Lotfifard
This paper proposes graph analysis methods to fully automate the fault location identification task in power distribution systems. The proposed methods take basic unordered data from power distribution systems as input, including branch parameters, load values, and the location of measuring devices. The proposed data preparation and analysis methods automatically identify the system's topology and extract essential information, such as faulted paths, structures, loading of laterals and sublaterals, and estimate the fault location accordingly. The proposed graph analysis methods do not require complex node and branch numbering processes or renumbering following changes in the system topology. The proposed methods eliminate the need for human intervention at any step of the fault location identification process. They are scalable and applicable to systems of any size. The performance of the proposed algorithm is demonstrated using the IEEE 34-bus distribution test system.