Glycosylation is considered a critical quality attribute of therapeutic proteins. Protein heterogeneity introduced by glycosylation includes differences in the nature, number and position of the glycans. Whereas analysis of released glycans and glycopeptides provides information about the composition and/or position of the glycan, intact glycoprotein analysis allows assignment of individual proteoforms and co-occurring modifications. Yet, resolving protein glycoforms at the intact level is challenging. We have explored the capacity of hydrophilic liquid chromatography-mass spectrometry (HILIC-MS) for assessing glycosylation patterns of intact pharmaceutical proteins by analyzing the complex glycoproteins interferon-beta-1a (rhIFN-β - 1a) and recombinant human erythropoietin (rhEPO). Efficient glycoform separation was achieved using a superficially-porous amide HILIC stationary phase and trifluoroacetic acid (TFA) as eluent additive. In-source collision-induced dissociation proved to be very useful to minimize protein-signal suppression effects by TFA. Direct injection of therapeutic proteins in aqueous formulation was possible without causing extra band dispersion, provided that the sample injection volume was not larger than 2 μL. HILIC-MS of rhIFN-β - 1a and rhEPO allowed the assignment of, respectively, 15 and 51 glycoform compositions, next to a variety of posttranslational modifications, such as succinimide, oxidation and N-terminal methionine-loss products. MS-based assignments showed that neutral glycan units significantly contributed to glycoform separation, whereas terminal sialic acids only had a marginal effect on HILIC retention. Comparisons of HILIC-MS with the selectivity provided by capillary electrophoresis-MS for the same glycoproteins, revealed a remarkable complementarity of the techniques. Finally it was demonstrated that by replacing TFA for difluoroacetic acid, peak resolution somewhat decreased, but rhEPO glycoforms with relative abundances below 1% could be detected by HILIC-MS, increasing the overall rhEPO glycoform coverage to 72.
Antibody-based pharmaceuticals often encompass a complex structural heterogeneity requiring enhanced analytical methods for reliable characterization of variants and degradation products. We have explored the capabilities of low-flow sheathless capillary electrophoresis-mass spectrometry (CE-MS) for the high-resolution and sensitive profiling of antibody therapeutics. Near-zero electroosmotic flow was achieved by employing a novel neutral capillary coating that also prevents protein adsorption. CE-MS analysis of intact model proteins using an acidic background electrolyte demonstrated satisfactory performance, with overall migration-time RSDs below 2.2% from three different capillaries tested. For system evaluation, three nanobody preparations, including mono- and bivalent forms, and three monoclonal antibodies (mAbs) were analyzed. Intact nanobodies were resolved from their degradation products, which could be assigned to deamidated, cleaved, and truncated forms at the C-terminal tag. Excellent resolution of isomeric deamidated products was obtained. The mAbs were analyzed intact and after digestion by the endoproteinase IdeS (middle-up approach). CE-MS of intact mAbs provided resolution of clipped species (e.g. light chain and light chain-heavy chain fragments) from the native protein. Moreover, glycoforms containing sialic acids were resolved from their non-sialylated counterparts. For IdeS-digested, F (ab)2 and Fc/2 portions where efficiently resolved for the three mAbs. Whereas the migration time of the Fc/2 fragments was fairly similar, the migration time of the F (ab)2 part was strongly varied among the mAbs. For all mAbs, separation of Fc/2 charge variants - including sialylated glycoforms and other post-translational modifications, such as loss of C-terminal lysine or asparagine deamidation - was achieved. This allowed a detailed and reliable assessment of the Fc/2 heterogeneity (18-33 proteoforms) of the three analyzed mAbs.
A novel analytical method based on hybrid trapped ion mobility spectrometry-time of flight mass spectrometry (TIMS-TOFMS) has been developed to achieve fast enantiomeric separation of amino acids (AAs). Resolution of chiral AAs was achieved by forming diastereomers through derivatization with the chiral agent (+)-1-(9-fluorenyl)ethyl chloroformate (FLEC), avoiding the use of reference compounds. Electrospray ionization (ESI) in positive mode yielded sodiated FLEC-AAs ions of which the diastereomers could be separated by TIMS. The effect of other alkali metal ions (such as Li and K) on the enantioselectivity was studied, but chiral discrimination was only observed for Na. TIMS conditions, including voltage ramp, ramp time and accumulation time were optimized for each AA, and collision cross sections (CCSs) were determined for all diastereomers. The migration order of the DL enantiomers was found to be dependent on the structure of the AA. The resulting TIMS resolution (K0/ΔK0) for the FLEC-AA diastereomers on average was 115, requiring a mobility (K0) difference of about 0.009 cm2/Vs to achieve 50%-valley separation. From the 21 AAs studied, enantiomer separation was achieved for 17 AAs with mobility differences ranging from 0.009 for lysine up to 0.061 cm2/Vs for asparagine. Moreover, the presented methodology provided mutual separation of various AAs, allowing chiral analysis of multiple AAs simultaneously which may be challenging with previous enantioselective IMS approaches. It appeared possible to fully resolve all studied DL-AAs using three distinct TIMS methods, resulting in a total MS run time of about 3 min (1 min per method) and a total analysis time (including derivatization) of less than 15 min. The method demonstrated capable to determine enantiomeric ratios down to 2.5% with detection limits for the D enantiomers in the nM range. This new TIMS-based methodology opens up possibilities for easy and fast analysis of AA enantiomers.
Determination of the impact of individual antibody glycoforms on FcɣRIIIa affinity, and consequently antibody-dependent cell-mediated cytotoxicity (ADCC) previously required high purity glycoengineering. We hyphenated FcɣRIIIa affinity chromatography to mass spectrometry, which allowed direct affinity comparison of glycoforms of intact monoclonal antibodies. The approach enabled reproduction and refinement of known glycosylation effects, and insights on afucosylation pairing as well as on low-abundant, unstudied glycoforms. Our method greatly improves the understanding of individual glycoform structure–function relationships. Thus, it is highly relevant for assessing Fc-glycosylation critical quality attributes related to ADCC.