Elmira Kujundzic

Dr. Elmira Kujundzic


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2012 in Journal of Membrane Science
Verified
Journal Article
Closed access
XLXiaoyun Lu
Xiaoyun Lu
EKElmira Kujundzic
Elmira Kujundzic
GMGuy Mizrahi
Guy Mizrahi
JWJay Wang
Jay Wang
KCKeith Cobry
Keith Cobry
AGAlan R. Greenberg
Alan R. Greenberg

10 August 2011 in Membranes
Verified
Journal Article
Open access
PDF file
EKElmira Kujundzic
Elmira Kujundzic
AGAlan R. Greenberg
Alan R. Greenberg
RFRobin Fong
Robin Fong
MHMark Thomas Hernandez
Mark Thomas Hernandez
Novel signal-processing protocols were used to extend the in situ sensitivity of ultrasonic frequency-domain reflectometry (UFDR) for real-time monitoring of microfiltration (MF) membrane fouling during protein purification. Different commercial membrane materials, with a nominal pore size of 0.2 µm, were challenged using bovine serum albumin (BSA) and amylase as model proteins. Fouling induced by these proteins was observed in flat-sheet membrane filtration cells operating in a laminar cross-flow regime. The detection of membrane-associated proteins using UFDR was determined by applying rigorous statistical methodology to reflection spectra of ultrasonic signals obtained during membrane fouling. Data suggest that the total power reflected from membrane surfaces changes in response to protein fouling at concentrations as low as 14 μg/cm2, and results indicate that ultrasonic spectra can be leveraged to detect and monitor protein fouling on commercial MF membranes.

1 March 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
Mads Koustrup JørgensenMads Koustrup Jørgensen
Mads Koustrup Jørgensen
EKElmira Kujundzic
Elmira Kujundzic
AGAlan R. Greenberg
Alan R. Greenberg
The effect of pressure on fouling layers formed by diluted activated sludge was studied in real time with ultrasonic reflectometry by fouling microfiltration membranes for 300 min at constant pressure (0.15 bar (15 kPa) and 0.25 bar (25 kPa)), as well as by performing a series of pressure-step experiments in which the pressure was instantaneously increased from 0.15 to 0.25 bar. For the constant pressure experiments, the change in ultrasonic signal amplitude was inversely proportional to the degree of fouling as represented by changes in permeability and the amount of deposited material. This finding was verified by a series of replicated filtration experiments of 15, 30, and 60-min duration at 0.15 bar, which indicated a statistically significant correlation between the degree of fouling (quantified by permeability loss and post-mortem characterization metrics) and ultrasonic amplitude change. Diluted activated sludge filtrations at varying pressures revealed that there is less ultrasonic amplitude reduction at higher pressure where the resistance of the fouling layer is higher. This finding reflects the formation of a hydrated fouling deposit that serves as an impedance matching layer with the water-filled membrane that produces lower reflection at lower pressure. Thus, the fouling layer is thought to be less hydrated and denser at higher pressures, which confirms that the fouling layer is a compressible structure. Given that fouling layer mechanical behavior may well influence membrane filtration performance, it may be possible to improve membrane bioreactor filtration by engineering fouling layer compressibility.