Using VSC-MTDC to provide frequency support for interconnected power systems is an attractive solution. Considering the disadvantages of traditional methods in power shortage or surplus absorption into the VSC-MTDC from AC systems requiring active power support (RAPS system) as well as flexible and effective power balance in AC systems providing active power support (PAPS system), this paper proposes a novel frequency support control method for interconnected power systems using VSC-MTDC. The main principle of the proposed frequency support control method is firstly to make the active power shortage or surplus of the RAPS system be fully and naturally absorbed into the DC grid with the AC slack bus mode control proposed for RAPS converters; in addition, the smooth switching control and the power limiting control are further proposed to realize smooth and safe power shortage or surplus absorption. Secondly, according to the proposed flexible PAPS systems matching strategy, one or more appropriate PAPS systems with adequate capacity are selected to effectively and accurately balance the unbalanced power via the corresponding PAPS converters using the active balancing power control. The theoretical analysis and simulation results using PSCAD/EMTDC have verified the validity, flexibility and universality of the proposed frequency support control method.
20 August 2018 in IEEE Transactions on Power Systems
Using VSC-MTDC for wind farm integration is considered to be a promising solution. In order to provide a stable AC voltage control and avoid active power control conflicts, amplitude-phase control strategy, rather than active/reactive power decoupled control strategy, is generally applied for the VSC connected to wind farms. However, using such a control strategy, the flexibility of power flow control will be partly lost. As the positive and negative pole DC networks in the bipolar VSC-MTDC can operate independently, a novel hybrid control strategy is proposed in this paper. In the proposed hybrid control strategy, the amplitude-phase control and active/reactive power decoupled control can be applied to the positive and negative poles, respectively. Hence the hybrid strategy combines the advantages of the amplitude-phase control and active/reactive power decoupled control and can be adapted to bipolar VSC-MTDC for large-scale wind farm integration. Simulation results using PSCAD show that the hybrid control strategy can provide stable AC voltage control and active/reactive power flow control for the integration of wind farms; moreover, such a hybrid control strategy is helpful to avoid the overload of DC lines, stabilize the DC voltage and enhance the power transfer capability.
8 November 2021 in IEEE Transactions on Power Delivery
Cascading commutation failure (CF) caused by the reactive power interaction between HVDC is one of the new forms of cascading failures in multi-infeed HVDC systems. However, the concept and mechanism of cascading CF have not been explained clearly, and few studies have been devoted to control strategy for cascading CF mitigation considering reactive power interaction. In this paper, the cascading CF is defined and novel coordinated control strategy for cascading CF mitigation is proposed. Firstly, the mechanism of cascading CF in multi-infeed HVDC systems is analyzed. Then influence degree of HVDC on the power system stability is evaluated considering both active power impact and reactive power interaction, based on which novel coordinated commutation failure prevention as well as voltage dependent dc current order limiter is developed to mitigate cascading CF. Simulation results based on CIGRE HVDC benchmark model in PSCAD/EMTDC verify the effectiveness and advancement of proposed strategy on cascading CF mitigation.
11 November 2021 in IEEE Transactions on Power Systems
Bipolar VSC-MTDC is a promising solution to increase power transmission capacity and system reliability for large-scale renewable energy integration. However, traditional interpolar active power control methods cannot comprehensively explore the maximum transmission capability of the bipolar VSC-MTDC under abnormal operating conditions. Considering the flexibility of the bipolar VSC-MTDC that the positive-pole and negative-pole DC networks can be operated independently, a novel fault self-recovering control strategy is proposed in this paper to provide automatic, global and timely recovery solutions under various fault conditions: (a) Firstly, a coordinated time-driven and event-driven security monitoring, optimization and recovering control framework is proposed to guarantee the accuracy and speed of the corresponding calculation and control, hence to meet the timeliness requirement of fault self-recovery; (b) Secondly, a global optimal power allocation calculation method is proposed to automatically calculate the optimal power allocation between the positive-pole and negative-pole DC networks; (c) Thirdly, an interpolar active power dispatch method is proposed to realize the fault self-recovering control strategy based on primary control strategies of bipolar VSC-MTDC. Simulation results using MATLAB and PSCAD/EMTDC show that the proposed control strategy can timely and effectively enhance the overall power transmission capability for large-scale renewable energy integration after the fault.
Meshed dc grid technology is an attractive solution to improve the operational reliability of a voltage source converter-based multi-terminal HVDC transmission (VSC-MTDC) system; in addition, the VSC-MTDC becomes widely accepted for the integration of large-scale renewable energy and power supply to passive ac grids. Hence, the performance requirements of the dc voltage control and the power control of the VSC-MTDC system become higher, and this is the key issue of coordinated control strategies for the VSC-MTDC system. Considering that the mainstream coordinated control under the above new situations is facing challenges in terms of dc voltage dynamic control performance or dynamic power deviation, this paper proposes an ac grids characteristic-oriented multi-point voltage coordinated control strategy for the VSC-MTDC system to provide satisfactory dynamic dc voltage control performance with minimized dynamic and steady state power deviations of the converter stations. The theoretical analysis and the simulations results based on PSCAD/EMTDC are to verify the effectiveness of the proposed control strategy.
An effective and accurate power flow algorithm provides control references for active power dispatch and initial steady state operating points, used for stability analysis, short-circuit calculations, and electromagnetic transient simulations, which is not only a fundamental precondition to analyze the system operating conditions, but also the basis to improve the accuracy of power flow and DC voltage control of the multi-terminal voltage source converter-based high voltage direct current (VSC-HVDC). This paper proposes a nodal voltage-based universal steady-state power flow algorithm for the newly-developed bipolar multi-terminal VSC-HVDC (VSC-MTDC). Firstly, as the positive-pole and negative-pole DC network of the bipolar VSC-MTDC can be operated individually, a bipolar power flow alternating iterative method is proposed here to obtain the positive/negative-pole DC network power flow. Secondly, a series of nodal equivalent methods involving various control strategies are proposed for the universal power flow algorithm. Then the detailed calculation procedure and a general MATLAB(TM) program for the universal power flow algorithm is presented. A typical 4-terminal bipolar VSC-MTDC system was built in the PSCAD/EMTDC to verify the validity of the proposed algorithm, and the results are discussed here. Moreover, the calculation results of more complex bipolar VSC-MTDC systems under different operating conditions, employing the proposed universal power flow algorithm, are presented to illustrate its universality and efficiency.