Marta Soler

Prof. Dr. Marta Soler

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2007 in The Veterinary Journal
Verified
Journal Article
Closed access
MSMarta Soler
Marta Soler
JMJosé Murciano
José Murciano
RLRafael Latorre
Rafael Latorre
EBEliseo Belda
Eliseo Belda
MRMaria J. Rodrı´guez
Maria J. Rodrı´guez
AGAmalia Agut Giménez
Amalia Agut Giménez

25 September 2015 in BMC Veterinary Research
Verified
Journal Article
Open access
PDF file
AVAquilino Alexander Villamonte
Aquilino Alexander Villamonte
HBH. van Bree
H. van Bree
BBBjg Broeckx
Bjg Broeckx
WDW. Dingemanse
W. Dingemanse
MSMarta Soler
Marta Soler
IGI. Gielen
I. Gielen
Diagnostic imaging is essential to assess the lame patient; lesions of the elbow joint have traditionally been evaluated radiographically, however computed tomography (CT) has been suggested as a useful technique to diagnose various elbow pathologies. The primary objective of this study was to determine the sensitivity and specificity of CT to assess medial coronoid disease (MCD), using arthroscopy as gold standard. The secondary objective was to ascertain the radiographic sensitivity and specificity for MCD compared with CT. For this study 180 elbow joints were assessed, of which 141 had been examined with radiography, CT and arthroscopy; and 39 joints, had radiographic and CT assessment. Sensitivity and specificity were calculated for CT and radiographic findings using available statistical software. Sensitivity and specificity of CT using arthroscopy as gold standard resulted in high values for sensitivity (100 %) and specificity (93 %) for the assessment of MCD. For the radiographic evaluation, a sensitivity of 98 % and specificity of 64 - 69 % using CT as the technique of reference, were found. These results suggest that in case of doubt during radiographic assessment, CT could be used as a non-invasive technique to assess the presence of MCD. Based on the high sensitivity and specificity obtained in this study it has been considered that CT, rather than arthroscopy, is the preferred noninvasive technique to assess MCD lesions of the canine elbow joint.

1 August 2016 in Research in Veterinary Science
Verified
Journal Article
Closed access
MSMarta Soler
Marta Soler
EDElisabet Dominguez
Elisabet Dominguez
XLXiomara Lucas
Xiomara Lucas
RNRosa Novellas
Rosa Novellas
KGKassia Valeria Gomes-Coelho
Kassia Valeria Gomes-Coelho
AGAmalia Agut Giménez
Amalia Agut Giménez

22 December 2021 in Animals
Verified
Journal Article
Open access
PDF file
AGAndré Marchina Gonçalves
André Marchina Gonçalves
FCFrancisco Gil Cano
Francisco Gil Cano
Francisco G. LaredoFrancisco G. Laredo
Francisco G. Laredo
MSMarta Soler
Marta Soler
AGAmalia Agut Giménez
Amalia Agut Giménez
Eliseo BeldaEliseo Belda
Eliseo Belda
The quadratus lumborum (QL) block targets the fascial plane surrounding the QL muscle providing abdominal somatic and visceral analgesia. The extension of its analgesic effects is a subject of research, as it could not cover areas of the cranial abdomen in dogs. This study assesses in eight thawed canine cadavers, the distribution of high-volume injections (0.6 mL kg−1 of a mixture of methylene blue and iopromide) injected between the psoas minor muscle and the vertebral body of L1. Anatomical features of the area of interest were studied in two cadavers. In another six dogs, QL blocks were performed bilaterally under ultrasound-guidance. The distribution of contrast was evaluated by computed tomography (CT). Hypaxial abdominal muscles were dissected to visualize the dye spread (spinal nerves and sympathetic trunk) in 5 cadavers. The remaining cadaver was refrozen and cross-sectioned. CT studies showed a maximum distribution of contrast from T10 to L7. The methylene blue stained T13 (10%), L1 (100%), L2 (100%), L3 (100%), L4 (60%) and the sympathetic trunk T10 (10%), T11 (20%), T12 (30%), T13 (70%), L1 (80%), L2 (80%), L3 (60%) and L4 (30%). These findings may suggest that despite the high volume of injectate administered, this modified QL block could not produce somatic analgesia of the cranial abdomen, although it could provide visceral analgesia in dogs.

2 May 2008 in Veterinary Radiology & Ultrasound
Verified
Journal Article
Closed access
PDF file
MSMarta Soler
Marta Soler
LCLuis Cardoso
Luis Cardoso
MTMarcio Teixeira
Marcio Teixeira
AGAmalia Agut Giménez
Amalia Agut Giménez

6 July 2023 in Animals
Verified
Journal Article
Open access
PDF file
AGAndré Marchina Gonçalves
André Marchina Gonçalves
Francisco G. LaredoFrancisco G. Laredo
Francisco G. Laredo
FCFrancisco Gil Cano
Francisco Gil Cano
MSMarta Soler
Marta Soler
AGAmalia Agut Giménez
Amalia Agut Giménez
Eliseo BeldaEliseo Belda
Eliseo Belda
The QL block is a high-level locoregional anesthesia technique, which aims to provide analgesia to the abdomen. Several approaches of the QL block have been studied to find out which one allows a greater distribution of the injectate. The aim of this study is to compare the traditional interfascial QL block (IQL) with a new latero-ventral approach (LVQL). We hypothesize that this new approach could be safer and easier to perform, since the injectate is administered more superficially and further away from vital structures. Our second objective is to assess whether a higher volume of injectate (0.6 mL/kg) could reach the ventral branches of the last thoracic nerves, leading to a blockade of the cranial abdomen. Six thawed canine cadavers (12 hemiabdomens) were used for this purpose. Both approaches were performed in all cadavers. A combination of methylene blue/iopromide was administered to each hemiabdomen, randomly assigned to the LVQL or IQL. No differences were found regarding the ease of perform the LVQL with respect to IQL. The results show that both techniques reached the ventral branches from L1 to L3, although only the IQL consistently stained the sympathetic trunk (5/6 IQL vs. 1/6 LVQL). The use of a higher volume did not enhance a more cranial distribution of the injectate.