Jae Ho Shin

Prof. Jae Ho Shin

Department of Chemistry, KwangWoon University, Seoul 01897, Korea
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2013 in Chemical Reviews
Verified
Journal Article
Closed access
SNScott P. Nichols
Scott P. Nichols
AKAhyeon Koh
Ahyeon Koh
WSWesley L. Storm
Wesley L. Storm
JSJae Ho Shin
Jae Ho Shin
MSMark H. Schoenfisch
Mark H. Schoenfisch

16 September 2015 in Analytical Chemistry
Verified
Journal Article
Closed access
HJHunho Jo
Hunho Jo
HGHyunwoo Gu
Hyunwoo Gu
WJWeejeong Jeon
Weejeong Jeon
HYHyungjun Youn
Hyungjun Youn
JHJin Her
Jin Her
Changill BanChangill Ban
Changill Ban

12 January 2016 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
Shabi Abbas ZaidiShabi Abbas Zaidi
Shabi Abbas Zaidi
JSJae Ho Shin
Jae Ho Shin
Glutathione, a low molecular mass thiol compound, is considered a vital biomarker for various disease and cancers owing to the variation in the level of GSH from its normal level in the micromolar to millimolar range in biological fluids and cells.

1 August 2014 in Acta Biomaterialia
Verified
Journal Article
Closed access
WSWesley L. Storm
Wesley L. Storm
JYJonghae Youn
Jonghae Youn
KRKatelyn P. Reighard
Katelyn P. Reighard
BWBrittany V. Worley
Brittany V. Worley
HLHetali M. Lodaya
Hetali M. Lodaya
MSMark H. Schoenfisch
Mark H. Schoenfisch

30 January 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MKMIn Ho Kang
MIn Ho Kang
SJSeong Sil Jeon
Seong Sil Jeon
SSSo Min Shin
So Min Shin
Mayura VeeranaMayura Veerana
Mayura Veerana
SJSang-Hye Ji
Sang-Hye Ji
Gyungsoon ParkGyungsoon Park
Gyungsoon Park
In this study, we generated water and phosphate buffer treated with microwave plasma-generated gas in which the major component was nitric oxide (PGNO), and investigated the efficiency of the treated water and buffer in fertilization and sanitation. Real time NO level monitored by an electrode sensor was linearly increased over PGNO injection time, and removal of O2 from liquid before PGNO injection accelerated NO assimilation into liquids. Residual NO was still present 16 h after PGNO injection was stopped. H2O2, NO2−, and NO3− were also detected in PGNO-treated liquids. Spinach plants applied with 10 and 30 times diluted PGNO-treated water and 0.5 mM phosphate buffer showed slightly higher height and dry weight than control after 5 weeks. Plants grown with 10 and 30 times diluted PGNO-treated water exhibited the increased tolerance to water deficiency. Significant anti-microbial activity within 1 h was observed in un-diluted and in half-diluted PGNO-treated water and 0.5 mM phosphate buffer. Our results suggest that water or phosphate buffer containing NO, H2O2, NO2−, and NO3− can be produced by PGNO treatment, and that PGNO-treated water or buffer can be used as a potential fertilizer enhancing plant vitality with sanitation effect.

6 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YLYoung Ju Lee
Young Ju Lee
JKJiyoon Kwon
Jiyoon Kwon
SSSanggyeong Shin
Sanggyeong Shin
YEYoung-Gyu Eun
Young-Gyu Eun
JSJae Ho Shin
Jae Ho Shin
GLGi-Ja Lee
Gi-Ja Lee
Salivary pepsin is a promising marker for the non-invasive diagnosis of laryngopharyngeal reflux (LPR). For reliable results regarding pepsin in saliva, it is critical to standardize the collection, storage, and pre-processing methods. In this study, we optimized the saliva collection protocols, including storage conditions, i.e., solution, temperature, and time, and the pre-processing filter for pepsin. Moreover, we prepared a simple immunochromatographic strip for the rapid detection of pepsin and evaluated its sensing performance. As a result, we selected a polypropylene (PP) filter as the pre-processing filter for salivary pepsin in low resource settings, such as those where point of care testing (POCT) is conducted. This filter showed a similar efficiency to the centrifuge (standard method). Finally, we detected the pepsin using gold nanoparticles conjugated with monoclonal pepsin antibody. Under optimized conditions, the lower limit of detection for pepsin test strips was determined as 0.01 μg/mL. Furthermore, we successfully detected the salivary pepsin in real saliva samples of LPR patients, which were pre-processed by the PP filter. Therefore, we expect that our saliva collection protocol and pepsin immunochromatographic strip can be utilized as useful tools for a non-invasive diagnosis/screening of LPR in POCT.