Han Zhang

Dr. Han Zhang

Texas A&M University
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
WZWen Zhang
Wen Zhang
CLChao Liu
Chao Liu
KHKuiguo Han
Kuiguo Han
XWXiaoou Wei
Xiaoou Wei
YXYiwei Xu
Yiwei Xu
ZCZhiyu Chen
Zhiyu Chen

15 May 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
HCHuaying Chen
Huaying Chen
JCJames Cornwell
James Cornwell
HZHan Zhang
Han Zhang
TLTse Lim
Tse Lim
RRRena Resurreccion
Rena Resurreccion
RNRobert E. Nordon
Robert E. Nordon
In vitro models of circulatory hemodynamics are required to mimic the microcirculation for study of endothelial cell responses to pulsatile shear stress by live cell imaging. This study reports the design, fabrication and characterisation of a microfluidic device that generates cardiac-like flow in a continuous culture system with a circulatory volume of only 2–3 μL. The device mimics a single chamber heart, with the following cardiac phases: (1) closure of the ventricle inlet valve, (2) contraction of the ventricle (systole) followed by opening of the outlet valve and (3) relaxation of the ventricle (diastole) with opening of the inlet valve whilst the outlet valve remains closed. Periodic valve states and ventricular contractions were actuated by microprocessor controlled pneumatics. The time-dependent velocity-field was characterised by micro-particle image velocimetry (μ-PIV). μ-PIV observations were used to help tune electronic timing of valve states and ventricular contractions for synthesis of an arterial pulse waveform to study the effect of pulsatile shear stress on bovine artery endothelial cells (BAECs). BAECs elongated and aligned with the direction of shear stress after 48 h of exposure to a pulsatile waveform with a maximum shear stress of 0.42 Pa. The threshold for BAECs alignment and elongation under steady (non-pulsatile) flow reported by Kadohama et al. (2006) is 0.7–1.4 Pa. These cells respond to transient shear stress because the time average shear stress of the pulse waveform to generate this morphological response was only 0.09 Pa, well below the steady flow threshold. The microfluidic pulse generator can simulate circulatory hemodynamics for live cell imaging of shear-induced signalling pathways.

4 September 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
HZHan Zhang
Han Zhang
AGAdrian R. Guzman
Adrian R. Guzman
JWJose A. Wippold
Jose A. Wippold
YLYuwen Li
Yuwen Li
JDJing Dai
Jing Dai
Arum HanArum Han
Arum Han
The integrated droplet platform combines curved microstructures that allow high-efficiency (99.9%) reflow of droplets and a droplet cleaving that automatically synchronizes paired droplets enabling high-efficiency (99.9%) downstream merging.

14 March 2019 in Analytical Chemistry
Verified
Journal Article
Closed access
CCChang Chen
Chang Chen
LZLitao Zhao
Litao Zhao
HZHan Zhang
Han Zhang
XSXiaoshuang Shen
Xiaoshuang Shen
Yonggang ZhuYonggang Zhu
Yonggang Zhu
Huaying ChenHuaying Chen
Huaying Chen

10 June 2019 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
HZHan Zhang
Han Zhang
ESEthan Smith
Ethan Smith
WZWei Zhang
Wei Zhang
AZAnhong Zhou
Anhong Zhou

30 December 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
CHCan Huang
Can Huang
YJYuqian Jiang
Yuqian Jiang
YLYuwen Li
Yuwen Li
HZHan Zhang
Han Zhang
Since being invented, droplet microfluidic technologies have been proven to be perfect tools for high-throughput chemical and biological functional screening applications, and they have been heavily studied and improved through the past two decades. Each droplet can be used as one single bioreactor to compartmentalize a big material or biological population, so millions of droplets can be individually screened based on demand, while the sorting function could extract the droplets of interest to a separate pool from the main droplet library. In this paper, we reviewed droplet detection and active sorting methods that are currently still being widely used for high-through screening applications in microfluidic systems, including the latest updates regarding each technology. We analyze and summarize the merits and drawbacks of each presented technology and conclude, with our perspectives, on future direction of development.