Ligai kang

Dr. Ligai kang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2023 in Energy Conversion and Management
Verified
Journal Article
Closed access
LKLigai kang
Ligai kang
JWJinzhu Wang
Jinzhu Wang
XYXiaoxue Yuan
Xiaoxue Yuan
ZCZilin Cao
Zilin Cao
YYYang Yang
Yang Yang
YWYongzhen Wang
Yongzhen Wang

1 October 2021 in Energy
Verified
Journal Article
Closed access
LKLigai kang
Ligai kang
XWXiaojing Wu
Xiaojing Wu
XYXiaoxue Yuan
Xiaoxue Yuan
KMKunru Ma
Kunru Ma
Yongzhen WangYongzhen Wang
Yongzhen Wang
QAQingsong An
Qingsong An

11 May 2022 in Energy
Verified
Journal Article
Closed access
LKLigai kang
Ligai kang
XYXiaoxue Yuan
Xiaoxue Yuan
KSKangjie Sun
Kangjie Sun
XZXu Zhang
Xu Zhang
JZJun Zhao
Jun Zhao
YWYongzhen Wang
Yongzhen Wang

24 September 2022 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Closed access
LKLigai kang
Ligai kang
XWXiaojing Wu
Xiaojing Wu
XYXiaoxue Yuan
Xiaoxue Yuan
Yongzhen WangYongzhen Wang
Yongzhen Wang

9 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
YWYongzhen Wang
Yongzhen Wang
CHCongchuan Hu
Congchuan Hu
BWBoyuan Wu
Boyuan Wu
JZJing Zhang
Jing Zhang
ZZZhenning Zi
Zhenning Zi
LKLigai kang
Ligai kang
Considering the huge power consumption, rapid response and the short-term heat reserving capacity of the air conditioning load in the building’s energy system, the air conditioning load and its system can be equivalent to the virtual energy storage device for the power grid. Therefore, to obtain a high matching building renewable energy system, a virtual energy storage system of the air conditioning load, accompanied by a storage battery, was built in the paper. Then, operating strategies for the virtual energy storage of the air conditioning load and storage battery were designed. Further, to quantize the contribution of the virtual energy storage to the improvement of matching characteristics, two indicators of the demand side and supply side in the energy system were adopted, including on-site energy fraction (OEFr) and on-site energy matching (OEMr). Lastly, matching characteristic research of the building’s renewable energy system based on virtual energy storage of the air conditioning load was established and analyzed by TRNSYS and MATLAB in Tianjin, China. The results revealed that a better matching characteristic performance of the building’s renewable energy systems driven by virtual energy storage was obtained. In the condition set out in the paper, compared with that without virtual energy storage, the average values of OEFr and OEMr after virtual energy storage were 0.66 and 0.77, which increased by 8.19% and 8.45% respectively. Simultaneously, the battery operation performance in the building renewable system was improved when the virtual energy storage was working. The times of charge and discharge cycles decreased after virtual energy storage, and the depth of discharge of the battery reduced by 23.37% on a specific day.

7 April 2020 in IEEE Access
Verified
Journal Article
Open access
LKLigai kang
Ligai kang
GWGang Wang
Gang Wang
YWYongzhen Wang
Yongzhen Wang
QAQingsong An
Qingsong An
With rapid development of smart grid, terminal power load is paid more and more attention, especially that of air conditioning system, which constitute an integral part of summer peak electricity load. In this paper, through controlling indoor air temperature deduced by equivalent thermal parameters-model, daily energy consumption and energy consumption during peak hours can be adjusted and reduced to realize demand side management. To reduce peak load of grid and ensure stable and reliable operation of grid, four temperature control strategies, including constant setting temperature control strategy, pre-cooling control strategy, curtailment control strategy and improved curtailment control strategy were proposed. Meanwhile, three operation schemes of the chiller were also employed. Furthermore, considering the power consumption and curtailment, five indicators including hourly average load, hourly average load ratio, energy saving ratio, load-shedding ratio during peak hours and coefficient of performance (COP) have been proposed to evaluate the performance. Results showed that the operation scheme of operating numbers control obtained better effect. Energy saving ratio was highest of 32.5% with curtailment control strategy, while load-shedding ratio during peak hours was optimal with improved curtailment control strategy. However, COP was maximum at 3.66 when pre-cooling control strategy was employed. This study can guide the operation of water-cooled air conditioning system through energy saving ratio and COP, also it has more benefits on economy of power system by hourly average load and load-shedding ratio.