A. Javier Mazon

Dr. A. Javier Mazon

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2011 in Electric Power Systems Research
Verified
Journal Article
Closed access
IBIbrahem Baqui
Ibrahem Baqui
IZInmaculada Zamora
Inmaculada Zamora
AMA. Javier Mazon
A. Javier Mazon
GBGarikoitz Buigues
Garikoitz Buigues

1 January 2016 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
EHElvira Fernandez Herrero
Elvira Fernandez Herrero
IAIgor Albizu
Igor Albizu
MLMiren Terese Bedialauneta Landaribar
Miren Terese Bedialauneta Landaribar
AMA. Javier Mazon
A. Javier Mazon
PLP.T. Leite
P.T. Leite

11 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
PGPatxi Gonzalez
Patxi Gonzalez
GBGarikoitz Buigues
Garikoitz Buigues
AMA. Javier Mazon
A. Javier Mazon
Electric machines are important devices that convert electrical energy into mechanical energy and are extensively used in a wide range of applications. Recent years have seen an increase in applications where electric motors are used. The frequent use of electric motors in noise-sensitive environments increases the requirements placed on electric motors intended for these applications, especially when compared to electric motors commonly used in industrial applications. This paper provides a comprehensive review of electric motor noise. Firstly, a brief introduction to noise is given. Then, the sources of electromagnetic noise and vibration in electric machines, including mechanical, aerodynamic and electromagnetic factors, are presented. Different methods such as analytical, numerical and semi-analytical for calculating electromagnetic force, natural frequencies and noise are also analyzed. Various methods for noise reduction are presented, including skewing, stator and rotor notching and slot opening width. Finally, noise measurement standards and procedures are described.

1 October 2007 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
IZI. Zamora
I. Zamora
AMA. Javier Mazon
A. Javier Mazon
KSK. J. Sagastabeitia
K. J. Sagastabeitia
JZJ. J. Zamora
J. J. Zamora
In electrical distribution systems, low current faults may be caused by a high impedance fault or by the fault current limitation caused by the neutral to ground connection. In the former case, an indirect contact or insulation degradation give a high value of the fault impedance. In the latter, the neutral grounding may be either isolated or compensated. Nevertheless, these types of faults do not produce enough current so that the traditional overcurrent relays or fuses are not able to detect the fault. This paper presents a new methodology, based on the superposition of voltage signals of certain frequency, for the detection of low current single phase faults in radial distribution systems. The simulation analysis and laboratory tests carried out have proved the validity of the methodology for any type of grounding method.

27 September 2012 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
IAIgor Albizu
Igor Albizu
EHElvira Fernandez Herrero
Elvira Fernandez Herrero
PEPablo Eguia
Pablo Eguia
ETEsther Torres
Esther Torres
AMA. Javier Mazon
A. Javier Mazon
Real-time monitoring allows the determination of the line state and the calculation of the actual rating value. The real-time monitoring systems measure sag, conductor tension, conductor temperature, or weather-related magnitudes. In this paper, a new ampacity monitoring system for overhead lines, based on the conductor tension, the ambient temperature, the solar radiation, and the current intensity is presented. The measurements are transmitted via general-packet radio service to a control center where a software program calculates the ampacity value. The system takes the creep deformation experienced by the conductors during their lifetime into account and calibrates the tension-temperature reference and the maximum-allowable temperature in order to obtain the ampacity. The system includes hardware implementation and remote-control software.

1 December 2000 in Electric Power Systems Research
Verified
Journal Article
Closed access
AMA. Javier Mazon
A. Javier Mazon
IZI. Zamora
I. Zamora
JMJ.F. Miñambres
J.F. Miñambres
MZM.A. Zorrozua
M.A. Zorrozua
JBJ.J. Barandiaran
J.J. Barandiaran
KSK. Sagastabeitia
K. Sagastabeitia